A computerized physiologic pulse duplicator for in-vitro hydrodynamic and ultrasonic studies of prosthetic heart valves



A computerized physiologic pulse duplicator for in-vitro hydrodynamic and ultrasonic studies of prosthetic heart valves



Biomedical Instrumentation and Technology 23(3): 205-215



A physiologic pulse duplicator for the simultaneous in-vitro hydrodynamic and ultrasonic evaluation of aortic prosthetic heart valves is described. The system is interfaced to a personal computer, which provides greater efficiency over manual techniques in system calibration, data acquisition, and analysis. The data analysis program aids selection of start and end systole and calculates pressure difference across the valve, the closing and regurgitant volumes, flow rates, and the Gabbay and Swanson performance indices. The pulse duplicator is designed to accommodate the ultrasonic measurement of fluid velocities, including pressure difference via the Bernoulli equation, and color-flow imaging. In tests of 19-mm, 23-mm, and 27-mm Bjork-Shiley spherical occluder valves, continuous-wave Doppler ultrasound was found to overestimate by about 50% the pressure difference measured directly by pressure transducers, a finding that is clinically important.

(PDF emailed within 1 workday: $29.90)

Accession: 039053879

Download citation: RISBibTeXText

PMID: 2752231


Related references

Pulse Duplicator Hydrodynamic Testing of Bioengineered Biological Heart Valves. Cardiovascular Engineering and Technology 7(4): 352-362, 2016

Design of a new pulse duplicator system for prosthetic heart valves. Journal of Biomechanical Engineering 109(1): 43-47, 1987

An aortic--left ventricular pulse duplicator used in testing prosthetic aortic heart valves. Journal of Thoracic and Cardiovascular Surgery 73(4): 550-558, 1977

A cardiovascular pulse duplicator for the in vitro assessment of artificial heart valves under physiological conditions. Life Support Systems 1 Suppl 1: 332-335, 1983

A mechanical pulse duplicator for testing prosthetic mitral and aortic valves. Thorax 17: 280-283, 1962

Photography of heart valves with the cardiac pulse duplicator. Journal of the Biological Photographic Association 25(4): 169-174, 1957

A manual pulse duplicator to test heart valves before implantation. Journal of Thoracic and Cardiovascular Surgery 66(1): 25-28, 1973

Improved design of a pulse duplicator to study the natural heart valves. Diseases of the Chest 51(1): 11-17, 1967

In vitro ultrasonic imaging of flow through prosthetic heart valves. Medical Instrumentation 21(2): 66-74, 1987

A computer controlled versatile pulse duplicator for precision testing of artificial heart valves. International Journal of Artificial Organs 16(10): 722-728, 1993

A comparison of five mechanical heart valves investigated in a pulse duplicator system with flexible vessels. Biomedizinische Technik. Biomedical Engineering 32(1-2): 9-15, 1987

In-vitro testing of three totally supra-annular bileaflet mechanical valves: hydrodynamics in the Sheffield pulse duplicator. Journal of Heart Valve Disease 17(2): 222-226, 2008

Duration of Systole and Diastole for Hydrodynamic Testing of Prosthetic Heart Valves: Comparison Between ISO 5840 Standards and in vivo Studies. Brazilian Journal of Cardiovascular Surgery 31(2): 171-173, 2017

Hydrodynamic function of ten prosthetic heart valves in the aortic position. Clinical Physics and Physiological Measurement 9(4): 307-317, 1988

Comparative hydrodynamic performance study of 28 commercially available prosthetic heart valves. Life Support Systems 2(SUPPL 1): 70-72, 1984