Accuracy of two wavelength pulse oximetry in neonates and infants



Accuracy of two wavelength pulse oximetry in neonates and infants



Pediatric Pulmonology 6(3): 180-182



In 60 neonates (gestational age, 26.5-40 weeks; postnatal age, 1-14 days) and in 11 infants (gestational age, 26-33 weeks; postnatal age, 4.5-38 weeks), the accuracy of two wavelength pulse oximetry was examined. A total of 112 comparisons between transcutaneous pulse oximetry saturation (StcO2, NELLCOR N-100) and arterial oxygen saturation (SaO2, OSM2 RADIOMETER) were obtained. SaO2 ranged from 80 to 100%. Criteria for comparison between StcO2 and SaO2 were standardized: patients in behavioral state 1, StcO2 stable for 2 min, and arterial samples drawn from an indwelling arterial line. StcO2 was significantly related to SaO2 (P less than 0.01), but the difference, StcO2 - SaO2, significantly increased when SaO2 decreased [StcO2 - SaO2(%) = -0.39 SaO2(%) + 37.95; r = -0.64, P less than 0.01]. No significant relationship was found between StcO2 - SaO2 and either bilirubinemia (range, 5-222 mumol/L) or fetal hemoglobin (HbF) (range, 12-95%). We conclude that StcO2 overestimates SaO2 when SaO2 decreases, and this overestimation is not due to high levels of bilirubin or HbF.

(PDF emailed within 0-6 h: $19.90)

Accession: 039155747

Download citation: RISBibTeXText

PMID: 2470014

DOI: 10.1002/ppul.1950060310



Related references

Accuracy of pulse oximetry in hypothermic neonates and infants undergoing cardiac surgery. Critical Care Medicine 24(3): 507-511, 1996

Accuracy of a new transmittance-reflectance pulse oximetry sensor in critically ill neonates. Critical Care Medicine 22(7): 1142-1146, 1994

Accuracy and reliability of pulse oximetry in premature neonates with respiratory distress. Aana Journal 56(3): 224-228, 1988

The accuracy of pulse oximetry in neonates: effects of fetal hemoglobin and bilirubin. Journal of Perinatology 7(4): 323-323, 1987

An audit of induction of anaesthesia in neonates and small infants using pulse oximetry. Anaesthesia 47(10): 896-899, 1992

Pulse oximetry and transcutaneous oxygen tension in hypoxemic neonates and infants with bronchopulmonary dysplasia. Advances in Experimental Medicine and Biology 220: 181-186, 1987

Effect of fetal haemoglobin on the accuracy of pulse oximetry in preterm infants. Journal of Paediatrics & Child Health 28(1): 43-46, 1992

The Effect of Skin Pigmentation on the Accuracy of Pulse Oximetry in Infants with Hypoxemia. Journal of Pediatrics (): -, 2016

Accuracy of pulse oximetry measurement of heart rate of newborn infants in the delivery room. Journal of Pediatrics 152(6): 756-760, 2008

Accuracy of pulse oximetry in assessing heart rate of infants in the neonatal intensive care unit. Journal of Paediatrics and Child Health 44(5): 273-275, 2007

Pulse oximetry screening for congenital heart defects in newborn infants (PulseOx): a test accuracy study. Lancet 378(9793): 785-794, 2011

Pulse oximetry in the air rescue service. 2: Methods of increasing the stability of pulse oximetry measurements--ECG-synchronized pulse oximetry and adhesive sensors. Anasthesiologie, Intensivmedizin, Notfallmedizin, Schmerztherapie 28(3): 174-178, 1993

Accuracy of two pulse oximetry devices with motion artifact reduction technology on Very Small Birth Weight infants in an intensive care nursery. Anesthesia & Analgesia 94(1S Supplement): S108, January, 2002

Masimo signal extraction technology pulse oximetry. Concerning the article by R.J. Rosychuk et al.: Discrepancies between arterial oxygen saturation and functional oxygen saturation measured with pulse oximetry in very preterm infants [Neonatology 2012;101:14-19. Neonatology 101(4): 239-40; Author Reply 240, 2013

Pulse oximetry as a screening test for congenital heart defects in newborn infants: a test accuracy study with evaluation of acceptability and cost-effectiveness. Health Technology Assessment 16(2): V-Xiii, 1-184, 2012