+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor



Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor



Journal of Clinical Monitoring 7(2): 161-167



A noninvasive blood pressure monitor (Finapres) that uses the methodology of Penaz to continuously display the arterial waveform from the finger has been introduced recently. The Finapres monitor overestimated systolic pressure by 5.8 +/- 11.9 mm Hg, while the Dinamap monitor underestimated systolic pressure by -6.9 +/- 9.2 mm Hg (P = 0.003). Dinamap mean and diastolic pressure biases were less than 2 mm Hg, while the Finapres biases for these variables were significantly greater (7.7 +/- 10.0 and 8.2 +/- 9.8 mm Hg, respectively). There was no difference in systolic or mean pressure precision between the two devices (approximately 10 mm Hg), but the diastolic precision of the Dinamap unit was superior to that of the Finapres. While in most patients the Finapres monitor provided continuous blood pressure data equivalent to the data from the radial artery, marked bias (greater than 15 mm Hg) was exhibited in 2 patients for all three pressure variables. Despite this bias, blood pressure changes were tracked closely in these 2 patients. We conclude that, in its current form, the Finapres monitor cannot be relied upon independently to accurately measure blood pressure in patients undergoing general anesthesia. Since the Dinamap monitor measures mean pressure reliably and accurately, we suggest that mean blood pressure values between the Finapres and Dinamap monitors be compared to guide one in interpreting Finapres data.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 039614377

Download citation: RISBibTeXText

PMID: 2072129

DOI: 10.1007/bf01618116


Related references

Different responses of Finapres and the oscillometric finger blood pressure monitor during intensive vasomotion. Journal of Medical Engineering and Technology 24(3): 95, 2000

Oscillometric blood pressure monitor which acquires blood pressure signals from composite arterial pulse signal. Official Gazette of the United States Patent & Trademark Office Patents 1203(4): 2695, 1997

Differences in orthostatic blood pressure changes measured with an oscillometric blood pressure monitor and a mercury sphygmomanometer. Blood Pressure. 5(4): 222-226, 1996

Oscillometric blood pressure monitor which automatically determines when to take blood pressure measurements. Official Gazette of the United States Patent & Trademark Office Patents 1196(1): 90, 1997

A home blood pressure monitor equipped with a graphic function facilitates faster blood pressure control than the conventional home blood pressure monitor. Journal of Clinical Hypertension 11(8): 422-425, 2009

Oscillometric blood pressure monitor with enhanced cuff pressure control. Official Gazette of the United States Patent & Trademark Office Patents 1193(1): 92, 1996

Validation of the OSCAR 2 oscillometric 24-hour ambulatory blood pressure monitor according to the International Protocol for the validation of blood pressure measuring devices. Blood Pressure Monitoring 9(4): 219-223, 2004

Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation. American Journal of Cardiology 114(7): 1046-1048, 2014

Oscillometric blood pressure monitor modeling. Conference Proceedings 2008: 303-306, 2008

Evaluation of a new ambulatory blood pressure monitor accutracker 102 laboratory comparisons with direct arterial pressure stethoscopic auscultatory pressure and readings from a similar monitor spacelabs model 5200. Psychophysiology 25(1): 107-116, 1988

Validation of the mobile wireless digital automatic blood pressure monitor using the cuff pressure oscillometric method, for clinical use and self-management, according to international protocols. Biomedical Engineering Letters 8(4): 399-404, 2018

Accuracy of an oscillometric blood pressure monitor in anesthetized pigs. Laboratory Animals 52(5): 490-496, 2018

Evaluation of an oscillometric blood pressure monitor for use in anesthetized cats. Journal of the American Veterinary Medical Association 221(5): 646-650, 2002

Evaluation of an oscillometric blood pressure monitor for use in anesthetized sheep. Veterinary Anaesthesia and Analgesia 40(6): E31-E39, 2013

The development of a blood pressure monitor based on oscillometric method. Zhongguo Yi Liao Qi Xie Za Zhi 26(4): 253-255, 2002