Compartment model for the determination of effective renal plasma flow using radionephrography
Rjabov, S.J.; Degtereva, G.A.
Radiologia Diagnostica 29(2): 351-356
1988
ISSN/ISBN: 0033-8354 PMID: 3387569 Accession: 039638433
Full Text Article emailed within 1 workday
Payments are secure & encrypted

Related References
Jakubowski, W. 1976: Calculation of effective renal plasma flow (ERPF) based on external recording of radioactivity decay in the circulation after a single dose of intravenous hippuran 131J. Part I: Determination of ERPF value according to the one compartment model Polski Przeglad Radiologii i Medycyny Nuklearnej 40(5): 335-341H.K., S.K.; Suga, Y.; Satou, H.; Tanaka, Y. 1994: The estimation of effective renal plasma flow based on two compartment analysis using 99mTc-mercaptoacetyltriglycine Japanese Journal of Nuclear Medicine 31(2): 175-181
Stritzke, P.H.; Kupfer, S.; Zhu, P.; Vallabhajosula, S.; Kim, C.K.; Burrows, L.; Goldsmith, S.J. 1990: Measurement of glomerular filtration rate gfr and renal plasma flow rpf or effective renal plasma flow erpf and renal plasma flow by a two minute dynamic scintigraphic study Journal of Nuclear Medicine 31(5 Suppl): 914
Cohen, M.L.; Patel, J.K.; Baxter, D.L. 1971: External monitoring and plasma disappearance for the determination of renal function: comparison of effective renal plasma flow and glomerular filtration rate Pediatrics 48(3): 377-392
Takayama, T.; Tada, A.; Aburano, T.; Tonami, N.; Hisada, K.; Yamada, M. 1983: Measurement of effective renal plasma flow with iodine 123 labeled o iodo hippurate comparison between separate effective renal plasma flow and renogram pattern Kaku Igaku 20(6): 841-847
Lear, J.L.; Feyerabend, A.; Gregory, C. 1989: Two-compartment, two-sample technique for accurate estimation of effective renal plasma flow: theoretical development and comparison with other methods Radiology 172(2): 431-436
Lear, J.L.; Feyerabend, A.; Gregory, C. 1989: Two-compartment, two-sample technique for accurate estimation of effective renal plasma flow: theoretical development and comparison with other methods Radiology 172(2): 431-436
Oriuchi, N.; Tokunaga, M.; Suzuki, H.; Inoue, T.; Ohnishi, Y.; Inoue, T.; Endo, K. 1995: Unilateral effective renal plasma flow measurement using one-compartment analysis of 99mTc-MAG3 and gamma-camera renography Nihon Igaku Hoshasen Gakkai Zasshi. Nippon Acta Radiologica 55(11): 757-762
Itkin, R.J.; Krawiec, D.R.; Twardock, A.R.; Gelberg, H.B.; Koritz, G.D. 1994: Evaluation of the single-injection plasma disappearance of technetium-99m mercaptoacetyltriglycine method for determination of effective renal plasma flow in dogs with normal or abnormal renal function American Journal of Veterinary Research 55(12): 1652-1659
Hoflin, F.; Luscher, D.; Jakob, B. 1991: Estimation of effective renal plasma flow comparison of a new two compartment two sample pc based technique versus oberhausen and tauxe method European Journal of Nuclear Medicine 18(8): 535
Itkin, R.J.; Krawiec, D.R.; Twardock, A.R.; Gelberg, H.B. 1994: Quantitative renal scintigraphic determination of effective renal plasma flow in dogs with normal and abnormal renal function, using 99mTc-mercaptoacetyltriglycine American Journal of Veterinary Research 55(12): 1660-1665
Calcagno, P.L.; Rubin, M.I. 1961: Determination of effective renal plasma flow in young infants following renal vein catheterization American Journal of Diseases of Children 102(4): 439-440
Oberhausen, E.; May, P.; Gloebel, B.; Emrani, I.; Kirsch, W. 1972: Determination of separate effective renal plasma flow comparison of nuclear medical and classical methods of determination Fortschritte auf dem Gebiete der Roentgenstrahlen und der Nuklearmedizin Suppl: 100-101
Ha-Kawa, S.K.; Suga, Y.; Satou, H.; Tanaka, Y. 1994: The estimation of effective renal plasma flow (ERPF) based on two compartment analysis using 99mTc-mercaptoacetyltriglycine (99mTc-MAG3) Kaku Igaku. Japanese Journal of Nuclear Medicine 31(2): 175-181
Held, J.P.; Daniel, G.B. 1991: Use of nonimaging nuclear medicine techniques to assess the effect of flunixin meglumine on effective renal plasma flow and effective renal blood flow in healthy horses American Journal of Veterinary Research 52(10): 1619-1621
Zurcher Mulder, A. 1967: A simplified method for the determination of effective renal plasma flow Clin Chim Acta 15(2): 219-231
Kataoka, Y.; Nishio, H.; Matsukiyo, R.; Kato, R.; Hasegawa, M.; Kenmochi, T.; Shiroki, R.; Toyama, H.; Ichihara, T.; Kobayashi, S. 2020: Measurement of effective renal plasma flow using model analysis of dynamic CT in the preoperative evaluation of the renal transplant donors Fujita Medical Journal 6(3): 73-80
Marshall, J.D.; Kearns, G.L. 1998: Bumetanide plasma compartment kinetic model can be linked to renal compartment effects Clinical Pharmacology and Therapeutics 63(2): 190
Coronil, C. 1964: Determination of Effective Renal Plasma Flow using I-131-Labelled Hippuran Clearance Revista Venezolana de Urologia 16: 221-235
Pilipenko, N.I. 1980: Determination of the effective renal plasma flow by hippuran-131i clearance Meditsinskaia Radiologiia 25(6): 85-87