Dependence of microbiologic test results of formaldehyde gas sterilization methods on the nature of the test material



Dependence of microbiologic test results of formaldehyde gas sterilization methods on the nature of the test material



Zentralblatt für Bakteriologie Mikrobiologie und Hygiene. Serie B Umwelthygiene Krankenhaushygiene Arbeitshygiene Praventive Medizin 184(2): 108-121



The efficiency of a formaldehyde gas sterilization procedure was evaluated with the aid of test pieces consisting of various materials. Both rigid and flexible tubes served as test pieces. The tubes were 75 cm long with an inner diameter of 1 mm and were sealed at one end. The bioindicators were placed inside the tubes close to the sealed end. Dried spores of Bacillus stearothermophilus adhering to linen threads served as test organisms. The test results varied according to the material of the test pieces and the thickness of their walls (see Table 1). In flexible tubes made of silicon rubber, all bioindicators became sterile, in tubes of stainless steel, all bioindicators exhibited test organisms that had survived. The findings for materials such as polyvinyl chloride, polyethylene, polyamide and polytetrafluorethylene ranged between these two extremes; the frequencies of bioindicators containing viable germs were 10, 55, 68 and 85%, respectively. Rigid and flexible tubes which had been sealed at both ends served to demonstrate that silicon rubber and polyvinyl chloride were highly permeable for formaldehyde and water vapour. Also the other plastic materials tested were permeable for formaldehyde and water vapour but longer exposure periods were needed to create conditions in the interior of the tubes that would result in a killing of the test organisms (see Fig 2). In this respect, polyamide exhibited a peculiar behaviour. The number of viable spores remained at the initial level for a long period before a decline took place. From the results of testing, it is concluded that test pieces must conform to the objects to be sterilized not only in their dimensions (length, inner diameter) but also in the characteristics of their material. The walls of the test pieces should not have a higher permeability for formaldehyde and water vapour than the material to be sterilized. The highest demands on the efficiency of formaldehyde gas sterilization procedures are those created by mental tubes and thick-walled flexible polytetrafluorethylene. Instruments and devices to be sterilized by a formaldehyde gas procedure should be preferentially made of materials which are sufficiently permeable for formaldehyde and water vapour as e.g. silicon rubber. Such gas-permeable components may considerably facilitate the sterilization of cavities which have a small lumen and are difficult to reach.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 039764235

Download citation: RISBibTeXText

PMID: 3113100


Related references

Microbiological testing of formaldehyde gas sterilization procedures dependency of results on the type of test piece material. Zentralblatt fuer Bakteriologie Mikrobiologie und Hygiene Serie B Umwelthygiene Krankenhaushygiene Arbeitshygiene Praeventive Medizin 184(2): 108-121, 1987

Dependency of the microbiological test results of a formaldehyde gas sterilization procedure on the shape of the objects to be sterilized. Zentralblatt fuer Bakteriologie Mikrobiologie und Hygiene Abt 1 Originale B Hygiene Umwelthygiene Krankenhaushygiene Arbeitshygiene Praeventive Medizin 177(5): 419-435, 1983

Comparative results in the detection of tuberculosis in hens with simultaneous use of tuberculin test, agglutination test and necropsy, microbiologic and histological studies. Gruzlica i Choroby Pluc; Tuberculosis et Pneumonologia 38(12): 1141-1148, 1970

Threshold for occluded formaldehyde patch test in formaldehyde-sensitive patients. Relationship to repeated open application test with a product containing formaldehyde releaser. Contact Dermatitis 36(1): 26-33, 1997

Proposal for standard methods in laboratory diagnostics cytomorphological test methods collection of specimens or test material collection of capillary blood. Zentralblatt fuer Pharmazie Pharmakotherapie und Laboratoriumsdiagnostik 129(12): 1003-1006, 1990

Dependency of a microbiological test of a formaldehyde gas sterilization procedure on the shape of objects to be sterilized. Zentralblatt für Bakteriologie Mikrobiologie und Hygiene. 1. Abt. Originale B Hygiene 177(5): 419-435, 1983

What should be the length and inner diameter of a test piece for microbiological testing of formaldehyde gas sterilization procedures. Zentralblatt fuer Bakteriologie Mikrobiologie und Hygiene Abt 1 Originale B Hygiene Umwelthygiene Krankenhaushygiene Arbeitshygiene Praeventive Medizin 179(5): 457-468, 1984

Etiology of testicular and epididymal changes in rams. 1. Test material, methods and results. Monatshefte für Veterinarmedizin 27(1): 31-37, 1972

Sterilization with formaldehyde vapors in a hypobaric procedure: microbiologic and toxicologic aspects. Zeitschrift für Urologie und Nephrologie 77(6): 363-372, 1984

Evaluation of the modified zinc test and the acid phosphatase test as preliminary screening methods in sexual assault case material. Forensic Science International 53(2): 135-141, 1992

Test for the efficacy of disinfectants at surfaces in test models. I. (communication:) Dependence of experimental results on the method of demonstration of surviving germs (swab and rinsing). Zentralblatt für Bakteriologie Parasitenkunde Infektionskrankheiten und Hygiene. Erste Abteilung Originale. Reihe B: Hygiene Praventive Medizin 161(5-6): 462-473, 1976

Investigations on the dimensions length and inner diameter of a test piece for use in microbiological efficiency testing of formaldehyde gas sterilization procedures. Zentralblatt fuer Bakteriologie Mikrobiologie und Hygiene Abt 1 Originale B Hygiene Umwelthygiene Krankenhaushygiene Arbeitshygiene Praeventive Medizin 181(1-2): 33-34, 1985

Test for the efficacy of disinfectants on surfaces in test models part 1 communication dependence of experimental results on the method of detecting surviving germs swabbing and rinsing. Zentralblatt fuer Bakteriologie Parasitenkunde Infektionskrankheiten und Hygiene Erste Abteilung Originale Reihe B Hygiene Krankenhaushygiene Betriebshygiene Praeventive Medizin 161(5-6): 462-473, 1976

Model tests for effectiveness assay of disinfectants on surfaces. III. Dependence of test results on the type of substances and the test microbes (Staphylococcus aureus, Mycobacterium terrae). Zentralblatt für Hygiene und Umweltmedizin 195(2): 97, 1994

Model tests for the efficiency of disinfectants on surfaces: III. Communication: Dependence of test results upon the kind of the active substances on the test germs (Staphylococcus aureus, Mycobacterium terrae). Zentralblatt fuer Hygiene und Umweltmedizin 195(2): 97-110, 1994