High-performance liquid chromatographic drug analysis by direct injection of whole blood samples. II. Determination of hydrophilic drugs



High-performance liquid chromatographic drug analysis by direct injection of whole blood samples. II. Determination of hydrophilic drugs



Journal of Chromatography 423: 155-161



The determination of hydrophilic drugs in whole blood by direct injection high-performance liquid chromatography was investigated. A pre-column equipped with an inlet filter of pore size 40 microns and an outlet filter of pore size 2 microns was packed with Butyl Toyopearl 650-M. A whole blood sample was injected directly into the pre-column to trap proteins, hydrophobic compounds and blood cytomembranes, and hydrophilic compounds emerged into an analytical column (Nucleosil 5SA, particle size 5 microns) and were determined after column switching. Proteins in 40 microliters of rabbit whole blood were adsorbed in the pre-column (0.63 ml of wet gel) in 0.4% perchloric acid solution. The recovery of procainamide and N-acetylprocainamide from whole blood was quantitative with good reproducibility (coefficient of variation less than 4%). It was shown that procainamide added to rabbit whole blood was subjected to N-acetylation by N-acetyltransferase in blood cells.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 040284567

Download citation: RISBibTeXText

PMID: 2450886

DOI: 10.1016/0378-4347(87)80338-9


Related references

High-performance liquid chromatographic drug analysis by direct injection of whole blood samples. I. Determination of moderately hydrophobic drugs incorporated into blood corpuscles. Journal of Chromatography 423: 147-153, 1987

High performance liquid chromatographic drug analysis by direct injection of whole blood samples iii. determination of hydrophobic drugs absorbed on blood cell membranes. Journal of Chromatography Biomedical Applications 423: 163-168, 1987

Determination of drugs in biological fluids by direct injection of samples for liquid-chromatographic analysis. Journal of Biochemical and Biophysical Methods 70(2): 263-273, 2007

High-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve. Journal Of Chromatography B. 709(1): 89-96, 8, 1998

High-performance frontal analysis-high-performance liquid chromatographic system for stereoselective determination of unbound ketoprofen enantiomers in plasma after direct sample injection. Journal of Pharmaceutical Sciences 81(7): 710-715, 1992

Routine determination of 8 common anti epileptic drugs and metabolites by high performance liquid chromatography using a column switching system for direct injection of serum samples. Journal of Chromatography Biomedical Applications 310(1): 97-106, 1984

Routine determination of eight common anti-epileptic drugs and metabolites by high-performance liquid chromatography using a column-switching system for direct injection of serum samples. Journal of Chromatography 310(1): 97, 1984

High-performance liquid chromatographic determination of cocaine and benzoylecgonine by direct injection of human blood plasma sample into an alkyl-diol-silica (ADS) precolumn. Analytical and Bioanalytical Chemistry 375(4): 534-538, 2003

Determination of drugs by direct injection of untreated blood plasma on reversed phase liquid chromatographic columns. Application to some antiepileptic drugs. Acta Pharmaceutica Suecica 23(2): 65-76, 1986

Determination of adriamycin and its metabolites in biological samples using high performance liquid chromatography. I. Analysis of serum and plasma by direct injection method. Yakugaku Zasshi 104(6): 614-619, 1984

Direct injection of blood samples into a high-performance liquid chromatographic adenine analyser to measure adenine, adenosine, and the adenine nucleotides with fluorescence detection. Journal of Chromatography 515: 363-373, 1990

Automated high-pressure liquid chromatographic assay for antiepileptic drugs and their major metabolites by direct injection of serum samples. Therapeutic Drug Monitoring 6(4): 478-483, 1984

Hydrophilic shielding of hydrophobic, cation- and anion-exchange phases for separation of small analytes: direct injection of biological fluids onto high-performance liquid chromatographic columns. Journal of Chromatography 544(1-2): 41-49, 1991

Direct-injection high-performance liquid chromatographic analysis of drug enantiomers in plasma with an avidin column coupled on-line to an ovomucoid column. Journal of Pharmaceutical Sciences 81(12): 1227-1228, 1992

High performance liquid chromatographic determination of ultra traces of two tricyclic antidepressant drugs imipramine and trimipramine in urine samples after their dispersive liquid-liquid microextraction coupled with response surface optimization. Journal of Pharmaceutical and Biomedical Analysis 100: 271-278, 2014