Magnetization transfer contrast: method for improving contrast in gradient-recalled-echo images



Magnetization transfer contrast: method for improving contrast in gradient-recalled-echo images



Radiology 179(1): 133-137



A method that improves contrast in gradient-recalled-echo magnetic resonance images is described. The increase in contrast is produced by applying low-power radio-frequency irradiation 5-10 kHz from the main water proton resonance frequency to excite macromolecular hydrogen-1 nuclei as part of a conventional gradient-recalled-echo sequence. The contrast so obtained is theoretically different from T1 or T2 contrast and has been termed magnetization transfer contrast. Cat head images were acquired in vivo with this method at 4.7 and 1.5 T. Compared with conventional gradient-recalled-echo images, the magnetization transfer images demonstrate increased contrast between many tissue pairs, such as between white matter and blood and between gray matter and cerebrospinal fluid. The dependence of the magnetization transfer effect on repetition time and preirradiation power were also studied.

(PDF emailed within 0-6 h: $19.90)

Accession: 040623549

Download citation: RISBibTeXText

PMID: 2006263

DOI: 10.1148/radiology.179.1.2006263


Related references

Use of magnetization transfer contrast in gradient-recalled echo images. Radiology 179(1): 15-16, 1991

Magnetization transfer contrast imaging of the skeletal muscle in gradient recalled echo sequence. Nihon Igaku Hoshasen Gakkai Zasshi. Nippon Acta Radiologica 53(2): 223-225, 1993

Use of magnetization transfer for improved contrast on gradient-echo MR images of the cervical spine. Radiology 193(1): 165-171, 1994

Magnetization transfer contrast of hepatic lesions in breath-hold gradient-echo images of different T1 weighting. Journal of Magnetic Resonance Imaging 7(2): 280-285, 1997

Comparison of a single shot T1-weighted in- and out-of-phase magnetization prepared gradient recalled echo with a standard two-dimensional gradient recalled echo: preliminary findings. Journal of Magnetic Resonance Imaging 33(6): 1482-1490, 2011

Comparison of T1-weighted in- and out-of-phase single shot magnetization-prepared gradient-recalled-echo with three-dimensional gradient-recalled-echo at 3 tesla Preliminary observations in abdominal studies. 2011

Comparison of T1-weighted in- and out-of-phase single shot magnetization-prepared gradient-recalled-echo with three-dimensional gradient-recalled-echo at 3.0 Tesla: preliminary observations in abdominal studies. Journal of Magnetic Resonance Imaging 35(5): 1187-1195, 2012

Magnetization transfer contrast on gradient echo MR imaging of the temporomandibular joint. Acta Radiologica 36(3): 295-299, 1995

Visualization of neuromelanin in the Substantia nigra and locus ceruleus at 1.5T using a 3D-gradient echo sequence with magnetization transfer contrast. Magnetic Resonance in Medical Sciences 7(4): 205-210, 2009

Pulsed magnetization transfer contrast in gradient echo imaging: A two-pool analytic description of signal response. Magnetic Resonance in Medicine 36(1): 95-103, 1996

Improved contrast of enhancing brain lesions on postgadolinium, T1-weighted spin-echo images with use of magnetization transfer. Radiology 190(2): 553-559, 1994

Intracranial MR angiography: application of magnetization transfer contrast and fat saturation to short gradient-echo, velocity-compensated sequences. Radiology 186(3): 753-761, 1993

Improving the contrast in rapid imaging sequences with pulsed magnetization transfer contrast. Journal of Magnetic Resonance 97(1): 171-176, 1969

Effect of magnetic susceptibility contrast medium on myocardial signal intensity with fast gradient-recalled echo and spin-echo MR imaging: initial experience in humans. Radiology 190(1): 161-166, 1994

Dynamic contrast enhancement patterns of solitary pulmonary nodules on 3D gradient-recalled echo MRI. Ajr. American Journal of Roentgenology 189(6): 1380-1386, 2007