Measurement of flow-resistive work of heat and moisture exchangers during simulated active breathing



Measurement of flow-resistive work of heat and moisture exchangers during simulated active breathing



Masui. Japanese Journal of Anesthesiology 39(6): 695-700



The performance of seven commercially available heat and moisture exchangers (HME) was evaluated in the dynamic flow state. A piston pump was used as a simulator with operative conditions with stroke volume of 500 ml and with respiratory rates of 20 and 40 cycles.min-1. A pressure-volume loop was produced for each HME and the flow-resistive work calculated. Each HME was studied under both dry and wet conditions. It was found that the flow-resistive work of the Humid-Vent 2 was the smallest and that of the Breathaid the largest under both conditions. The results suggest that application of HME causes a significant increase in resistance and demands a greater breathing effort from patients. Its use should thus be avoided in marginal patients.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 040651791

Download citation: RISBibTeXText

PMID: 2388387


Related references

The work of breathing with heat and moisture exchangers in the circle breathing system. Anesthesiology 79(3A): A500, 1993

The work of breathing imposed by heat and moisture exchangers during weaning. Anesthesiology 79(3A): A295, 1993

Variability of pressure-time product and work of breathing imposed by different heat and moisture exchangers before and after prolonged use. Clinical Intensive Care 10(5): 183-189, 1999

Influence of breathing resistance of heat and moisture exchangers on tracheal climate and breathing pattern in laryngectomized individuals. Head and Neck 32(8): 1069-1078, 2010

Effects of heat and moisture exchangers on minute ventilation, ventilatory drive, and work of breathing during pressure-support ventilation in acute respiratory failure. Critical Care Medicine 24(7): 1184-1188, 1996

Heat and moisture exchangers for humidifying the inspired air of intubated patients in intensive care medicine. An investigation of humidification properties of heat and moisture exchangers under clinical conditions. Anaesthesist 44(4): 274-283, 1995

Heat and moisture exchangers and breathing filters. British Journal of Anaesthesia 73(2): 227-236, 1994

Technische Untersuchung zur Frage der Wirksamkeit von Heat and Moisture Exchangers (HME). Technical Study on the Efficiency of Heat and Moisture Exchangers (HME). Biomedical Engineering/ Biomedizinische Technik 32(11): 270-276, 1987

Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing. Plos one 10(7): E0133432, 2015

In vitro evaluation of heat and moisture exchangers designed for spontaneously breathing tracheostomized patients. Respiratory Care 58(11): 1878-1885, 2013

Laboratory evaluation of 10 heat and moisture exchangers using simulated aeromedical evacuation conditions. Military Medicine 176(6): 656-659, 2011

Work of ventilating heat and moisture exchangers. British Journal of Anaesthesia 67(5): 647P-648P, 1991

Impact of heat and moisture exchangers on ventilatory pattern and respiratory mechanics in spontaneously breathing patients. Monaldi Archives for Chest Disease 49(6): 561-564, 1994

Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 1 - history, principles and efficiency. Anaesthesia 66(1): 31-39, 2011

Resistance to gas flow in heat and moisture exchangers. Anaesthesia 47(12): 1095-1096, 1992