To assess the possibility of indirect damage by CO2 laser reflection from specialized or modified tracheal tubes, four different tracheal tubes were studied. They were (1) a Rusch red rubber tracheal tube wrapped with 3M No. 425 aluminum foil tape, (2) a Rusch red rubber tracheal tube wrapped with Venture copper foil tape, (3) a polyvinylchloride tracheal tube wrapped with Laser-Guard protective coating, and (4) a Mallinckrodt Laser-Flex tracheal tube. The tracheal tubes were straightened and centered within cardboard cylinders and the laser set to 40 W was aimed to reflect from the tracheal tubes onto the cardboard. The times to combustion perforating the cardboard cylinders because of laser reflection were 1.41 +/- 0.54 (mean +/- SD), 1.73 +/- 0.93, 3.70 +/- 2.18, and 9.26 +/- 3.40 s for tracheal tubes 1, 2, 3, and 4, respectively. The differences between the times to combustion with tracheal tubes 3 and 1, 3 and 2, 4 and 1, 4 and 2, and finally, 4 and 3 were statistically significant. We conclude that the Laser-Guard-wrapped polyvinylchloride tracheal tube and the Mallinckrodt Laser-Flex tracheal tube were less reflective of incident CO2 laser radiation than the copper or aluminum-foil-wrapped red rubber tracheal tubes.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 041202396

Download citation: RISBibTeXText

PMID: 1907818

DOI: 10.1213/00000539-199109000-00019


Related references

Reflection of carbon dioxide laser radiation from laser resistant endotracheal tubes. Anesthesia & Analgesia 73(3): 338-340, 1991

Hazards of carbon dioxide laser reflection from laser resistant endotracheal tubes. Anesthesiology 71(3A): A444, 1989

Comparison of xomed treace laser shield II and Sheridan Laser Trach Laser Resistant endotracheal tubes subjected to CO-2 laser. Anesthesiology 81(3A): A492, 1994

Are laser-resistant endotracheal tubes safe with the new holmium:YAG infrared laser?. European Journal of Anaesthesiology 10(6): 433-436, 1993

Avoiding a wrapped endotracheal tube in laser laryngeal surgery: experiences with apneic anesthesia and metal laser-flex endotracheal tubes. Laryngoscope 100(12): 1283-1287, 1990

Hazard of laser reflection from foil protected endotracheal tubes. Lasers in Surgery & Medicine (Suppl. 1): 51-52, 1989

Laser resistant endotracheal tubes how safe are they. Lasers in Surgery & Medicine (Suppl. 2): 57-58, 1990

Xomed laser-shield endotracheal tubes: flammable tubes still being used. Health Devices 20(11): 444-445, 1991

Endotracheal tubes for CO2 laser surgery of the larynx. Hno 32(1): 28-31, 1984

Hazard to Endotracheal Tubes by Co 2 Laser Beam. Orl 47(1): 22-25, 1985

A Comparison of Laser-Protected Endotracheal Tubes. Otolaryngology--Head and Neck Surgery 159(5): 871-878, 2018

A further modification of endotracheal tubes for laser microsurgery. Anesthesiology 53(1): 81, 1980

Polyvinylchloride endotracheal tubes are hazardous for CO2 laser surgery. Anesthesiology 69(5): 801-802, 1988

Comparative analysis of the safety of endotracheal tubes with the KTP laser. Laryngoscope 99(7 Pt 1): 748-751, 1989

Flammability of endotracheal tubes during Nd-YAG laser application in the airway. Anesthesiology 65(5): 511-515, 1986