Three-dimensional SPECT reconstruction of combined cone beam and parallel beam data



Three-dimensional SPECT reconstruction of combined cone beam and parallel beam data



Physics in Medicine and Biology 37(3): 535-548



Single photon emission computed tomography (SPECT) using cone beam (CB) collimation exhibits increased sensitivity compared with acquisition geometries using parallel (P) hole collimation. However, CB collimation has a smaller field-of-view which may result in truncated projections and image artifacts. A primary objective of this work is to investigate maximum likelihood-expectation maximization (ML-EM) methods to reconstruct simultaneously acquired parallel and cone beam (P&CB) SPECT data. Simultaneous P&CB acquisition can be performed with commercially available triple camera systems by using two cone-beam collimators and a single parallel-hole collimator. The loss in overall sensitivity (relative to the use of three CB collimators) is about 15 to 20%. We have developed three methods to combine P&CB data using modified ML-EM algorithms. The first method consists of using both data sets to reconstruct a single intermediate image after each iteration using the ML-EM algorithm. The other two iterative algorithms combine intermediate parallel beam (PB) and CB source estimates to enhance image quality. For these methods, a PB estimate and a CB estimate are obtained for the first iteration. The second method consists of summing the PB and CB estimates for each subsequent iteration to obtain new PB and CB estimates. The third method is similar to the second method, with the exception that the new PB estimate simply is set equal to the PB estimate after each iteration. The combined source estimate is used in each subsequent iteration step of the EM algorithm. These algorithms are evaluated using projection data simulated using a Monte Carlo SPECT model. The P&CB SPECT images demonstrate marked improvement as compared with the CB-only reconstruction, particularly when the projections are truncated.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 041802403

Download citation: RISBibTeXText

PMID: 1565689

DOI: 10.1088/0031-9155/37/3/003


Related references

Filtered backprojection reconstruction of combined parallel beam and cone beam SPECT data. Physics in Medicine and Biology 40(9): 1517-1537, 1995

Physical phantom evaluation of 3D reconstruction of combined cone-beam and parallel-beam SPECT acquisition. Journal of Nuclear Medicine 43(5 Suppl.): 215P, 2002

Evaluation of combined cone beam with parallel hole collimation spect data. Journal of Nuclear Medicine 32(5 Suppl.): 956, 1991

An evaluation of lesion detectability with cone beam, fan beam and parallel beam collimation in SPECT by continuous ROC analysis. Journal of Nuclear Medicine 34(5 Suppl. ): 81P, 1993

A comparison of parallel beam, fan beam, and cone beam collimators for 3D SPECT brain imaging based on mutual information criterion. Journal of Nuclear Medicine 34(5 Suppl. ): 195P-196P, 1993

Revisit of combined parallel-beam/cone-beam or fan-beam/cone-beam imaging. Medical Physics 40(10): 100701, 2013

Simultaneous cone-beam and parallel-beam acquisition for SPECT scintimammography Initial phantom evaluation. Journal of Nuclear Medicine 43(5 Suppl.): 220P, 2002

An evaluation of lesion detectability with cone-beam, fanbeam and parallel-beam collimation in SPECT by continuous ROC study. Journal of Nuclear Medicine 35(1): 135-140, 1994

A comparison of myocardial defect detection in thallium 201 spect using parallel hole fan beam and cone beam collimators. Journal of Nuclear Medicine 32(5 Suppl.): 946, 1991

Shift-variant filtered-backprojection for a dual cone-beam and parallel-beam collimator SPECT camera. Journal of Nuclear Medicine 35(5 Suppl. ): 5P, 1994

Three-dimensional reconstruction from cone-beam data using an efficient Fourier technique combined with a special interpolation filter. Physics in Medicine and Biology 43(4): 951-959, 1998

Analytical fan-beam and cone-beam reconstruction algorithms with uniform attenuation correction for SPECT. Physics in Medicine and Biology 50(13): 3153-3170, 2005

Cardiac SPECT using combined cone-beam and fan-beam collimation. Journal of Nuclear Medicine 44(5 Suppl.): 63P, 2003

A novel extension of the parallel-beam projection-slice theorem to divergent fan-beam and cone-beam projections. Medical Physics 32(3): 654-665, 2005

Three-dimensional reconstruction from cone-beam data in O(N3 log N) time. Physics in Medicine and Biology 39(3): 477-491, 1994