Use of end-tidal PCO2 and transcutaneous PCO2 as noninvasive measurement of arterial PCO2 in extubated patients recovering from general anesthesia



Use of end-tidal PCO2 and transcutaneous PCO2 as noninvasive measurement of arterial PCO2 in extubated patients recovering from general anesthesia



Journal of Clinical Monitoring 8(3): 226-230



This study was designed to assess the accuracy of end-tidal PCO2 and transcutaneous PCO2 as measurements of arterial PCO2 in extubated, spontaneously breathing patients recovering from general anesthesia. In 30 patients, measurement of arterial transcutaneous, and end-tidal PCO2 were taken simultaneously with body temperature approximately every 15 minutes over a 2-hour period. Arterial PCO2 values were corrected for body temperature. Values for PaCO2 were compared with those for PETCO2 and PsCO2 by linear regression analysis and by calculation of bias +/- precision. Thirty-six percent of the capnogram tracings obtained did not develop a plateau phase. We found poor correlation between end-tidal and arterial PCO2 regardless of the shape of the capnogram tracing, as well as poor correlation between transcutaneous and arterial PCO2. Although the measurements of bias and precision of noninvasive PCO2 monitors in this population are comparable to studies in other populations, we advise caution in relying on the routine use of PETCO2 or PsCO2 for the noninvasive assessment of respiratory depression in extubated, spontaneously breathing patients recovering from general anesthesia.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 041917882

Download citation: RISBibTeXText

PMID: 1494929


Related references

Die pCo2-/pO2-Optode: Eine neue p Co2- bzw. pO2-Mesonde zur Messung des pCo2 oder pO2 von Gasen und Flssigkeiten / The pCo2-/pO2-Optode: A New Probe for Measurement of pCo2 or pO2 in Fluids and Gases. Zeitschrift für Naturforschung C 30(7-8): 532-533, 1975

Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device. Chest 113(3): 768-773, 1998

The accuracy of transcutaneous PCO2 in subjects with severe brain injury: a comparison with end-tidal PCO2. Respiratory Care 59(8): 1242-1247, 2015

Arterial PO2, PCO2, and pH versus transcutaneous PO2 and PCO2 and tissue pH in the fetal dog. American Journal of Obstetrics and Gynecology 155(2): 437-443, 1986

Can prolonged expiration manoeuvres improve the prediction of arterial PCO2 from end-tidal PCO2?. British Journal of Anaesthesia 78(5): 536-540, 1997

Estimation of arterial PCO2 from end-tidal PCO2 and oxygen saturation in cyanotic children. Journal of Cardiothoracic Anesthesia 3(5 Suppl 1): 35, 1989

Can we improve the estimate of arterial PCO2 from end-tidal PCO2?. European Journal of Anaesthesiology 17(5): 306-310, 2000

The effect of hyperthermia on PCO2, , pH and lactate concentrations of arterial blood and cisternal cerebrogpinal fluid in dogs at constant end-tidal pCO2. FED PROC 20(1 Pt 1): 212, 1961

Can one predict arterial PCO2 from end-tidal PCO2?. British Journal of Anaesthesia 72(4): 495, 1994

Prediction of arterial PCO2 from end-tidal PCO2. British Journal of Anaesthesia 71(6): 917-918, 1993

Hypercapnic ventilatory responses measured by transcutaneous PCO2 are more linear than those measured by end-tidal PCO2. Jikeikai Medical Journal 49(3): 127-132, 2002

Gastric mucosal-to-end-tidal PCO2 difference during major abdominal surgery: influence of the arterial-to-end-tidal PCO2 difference?. European Journal of Anaesthesiology 20(2): 147-152, 2003

Flap monitoring by transcutaneous PO2 and PCO2: importance of transcutaneous PCO2 in determining follow-up treatment for compromised free flaps. Journal of Reconstructive Microsurgery 23(5): 269-274, 2007

Skin blood flow influences the transcutaneous PCO2 (tc PCO2) during stress in the guinea pig. Journal of Perinatal Medicine 24(2): 155-161, 1996

PCO2-optode, fluorescence fotometric device to measure the transcutaneous PCO2. Birth Defects Original Article Series 15(4): 123-126, 1979