Absolute measures of physical image quality: measurement and application to radiographic magnification



Absolute measures of physical image quality: measurement and application to radiographic magnification



Medical Physics 9(4): 540-549



Two absolute measures of physical image quality [noise equivalent quanta (NEQ) and detective quantum efficiency (DQE)] are reviewed and calculated as functions of spatial frequency from measurements of the imaging characteristics of radiographic screen-film systems. NEQ is the effective number of information bearing quanta used to form an image, and DQE is the ratio of NEQ to the actual number of quanta used. NEQ and DQE are derived from the sensitometric characteristic, modulation transfer function (MTF), and noise power spectrum (NPS) of a screen-film system. Spatial frequency (f) distributions of NEQ and DQE were determined for three calcium tungstate screens [Du Pont Cronex Detail, Par Speed and Hi-Plus] used with Kodak XRP film. The relative ranking of NEQ(f) of these 3 systems followed the ranking of MTF and the exposure required to produce a given film density (Detail > Par Speed > Hi Plus). The ranking of DQE(f) followed that of system speed (Hi Plus > Par Speed > Detail) at frequencies < 2.5 cycles/mm, but was the same as the ranking of NEQ(f) at frequencies > 5 cycles/mm. Noise equivalent apertures defined in terms of MTF were larger than analogous apertures defined in terms of NEQ for these screen-film systems, suggesting that, for a specific imaging task, these systems introduce more degradation in image quality due to loss of contrast than to loss of signal-to-noise ratio (SNR). Finally, the application of NEQ(f) and DQE(f) distributions to imaging system analysis is demonstrated by applying them to an optimization of magnification radiography with respect to image SNR.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 042147134

Download citation: RISBibTeXText

PMID: 7110085

DOI: 10.1118/1.595099


Related references

Direct radiographic magnification for skeletal radiology. An assessment of image quality and clinical application. Radiology 123(1): 47-55, 1977

Some physical factors affecting radiographic image quality: their theoretical basis and measurement. Environmental Health Series. Rh, Radiological Health 38: 1-100, 1969

Quality of image in ampliphotography with the 0.3 mm image, with and without geometrical magnification. Application in radiopediatrics. Journal de Radiologie, D'electrologie, et de Medecine Nucleaire 55(10): 642-644, 1974

Comparison of image quality obtained with optical and radiographic magnification techniques in fine-detail skeletal radiography: effect of object thickness. Radiology 118(1): 189-195, 1976

Radiographic image magnification as quality control of microcalcification imaging within the scope of histopathological control of breast biopsy tissue. Rofo 172(1): 68-72, 2000

Pluridirectional macrotomography with three-fold magnification. An assessment of image quality and clinical application. European Journal of Radiology 4(1): 76-81, 1984

Investigation of image quality identification utilizing physical image quality measurement in direct- and indirect-type of flat panel detectors and computed radiography. Nihon Hoshasen Gijutsu Gakkai Zasshi 67(11): 1415-1425, 2012

Penetration quality measurement for standardization of radiographic image quality. Medical Physics 2(1): 5-8, 1975

The Effect Of Some Physical Factors On Radiographic Image Quality. Radiology 84: 123-124, 1965

Application of objective image quality measures on CT image. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi 28(2): 357-364, 2012

A comparison of conventional mammographic magnification, ultra high magnification and industrial magnification radiography in the radiographic detection of microcalcifications within core biopsies of the breast. British Journal of Radiology 70(839): 1099-1103, 1998

Effect of radiographic magnification on image contrast of blood vessels. Ajr. American Journal of Roentgenology 134(1): 159-192, 1980

Effect of quantum mottle and modulation transfer on the measurement of radiographic image quality. Proceedings of the Second Colloquium on Diagnostic Radiologic Instrumentation: Modulation transfer function, Chicago, Ill , April, 1964 350-369, 1965

Simulation study of radiographic image quality measurement based on transmitted information. Nihon Hoshasen Gijutsu Gakkai Zasshi 63(3): 341-344, 2007