EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Automated determination of drugs in blood samples after enzymatic hydrolysis using precolumn switching and post-column reaction detection



Automated determination of drugs in blood samples after enzymatic hydrolysis using precolumn switching and post-column reaction detection



Journal of Chromatography 255: 79-90



Enzymatic hydrolysis of blood samples with subtilisin-A releases protein-bound drugs and permits the repeated (10-50 times) injection of up to 1-ml volumes on short (2-30 mm) precolumns without appreciable build-up of pressure or loss of performance of the precolumn. The principle of fully automated serum and plasma analysis is demonstrated with the drug secoverine as a model compound. After enzymatic hydrolysis of the sample with an equal volume of a 1 mg/ml solution of subtilisin-A for 15 min at 55 degrees C, the model compound is preconcentrated using a microprocessor-controlled column switching unit. Separation occurs in a reversed-phase liquid chromatographic system using a CN-type stationary phase and a buffered aqueous dioxane solution as mobile phase. Detection is done by UV spectrophotometry or fluorometrically after post-column ion-pairing reaction with dimethoxyanthracenesulphonate. The relative standard deviation of the procedure is less than +/- 6% (n = 10).

(PDF emailed within 0-6 h: $19.90)

Accession: 042348331

Download citation: RISBibTeXText

PMID: 6345562

DOI: 10.1016/s0021-9673(01)88275-3



Related references

Determination of drugs and their metabolites in biological samples by fully automated hplc with on line solid liquid extraction and pre column switching. Frei, R W And K Zech (Ed ) Journal Of Chromatography Library, Vol 39 Selective Sample Handling And Detection in High-Performance Liquid Chromatography, Part A Xi+457p Elsevier Science Publishers B V : Amsterdam, Netherlands; New York, New York, Usa Illus 81-144, 1988

Determination of Glucose in Submicroliter Samples by CE-LIF Using Precolumn or On-Column Enzymatic Reactions. Analytical Chemistry 69(7): 1326-1331, 1997

Determination of methotrexate and its metabolite 7-hydroxymethotrexate by direct injection of human plasma into a column-switching liquid chromatographic system using post-column photochemical reaction with fluorimetric detection. Journal Of Chromatography B. 689(2): 379-386, 1997

Monitoring of enzymatic hydrolysis of starch by microdialysis sampling coupled on-line to anion exchange chromatography and integrated pulsed electrochemical detection using post-column switching. Biotechnology and Bioengineering 56(5): 546-554, 2008

Automated analysis of quetiapine and other antipsychotic drugs in human blood by high performance-liquid chromatography with column-switching and spectrophotometric detection. Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences 830(2): 342-348, 2005

Application of a semi-automated 96-well format solid-phase extraction, column-switching, fluorescence detection protocol for the determination of alendronate in human urine samples obtained from a bioequivalence study. Journal of Pharmaceutical and Biomedical Analysis 43(3): 1151-1155, 2006

Automated determination of amoxicillin in biological fluids by column switching in ion pair reversed phase liquid chromatographic systems with post column derivatization. Journal of Chromatography Biomedical Applications 344: 285-296, 1985

GC/MS with post-column switching for large volume injection of headspace samples: sensitive determination of volatile organic compounds in human whole blood and urine. Analytical Chemistry 83(4): 1475-1479, 2011

Automated determination of drugs in serum by liquid chromatography with column-switching. I. Separation of antiepileptic drugs and metabolites. Clinical Chemistry 34(1): 141-144, 1988

Determination of rat blood S-D-lactoylglutathione by a column-switching high-performance liquid chromatography with precolumn fluorescence derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiazole. Analytical Biochemistry 330(2): 186-192, 2004

Automated determination of oxytetracycline residues in muscle, liver, milk and egg by on-line dialysis and post-column reaction detection HPLC. Food Additives and Contaminants 9(6): 615-622, 1992

Determination of N-methylcarbamate pesticides in water and vegetable samples by HPLC with post-column chemiluminescence detection using the luminol reaction. Analytica Chimica Acta 630(2): 194-204, 2008

Determination of N-methylcarbamate pesticides in water, vegetable samples by HPLC with post-column chemiluminescence detection using the luminol reaction. 2008

Improved method for the determination of kynurenic acid in rat plasma by column-switching HPLC with post-column fluorescence detection. Analytica Chimica Acta 562(1): 36-43, 2006