Continuous registration of blood velocity and cardiac output with a hot-film anemometer probe, mounted on a Swan-Ganz thermodilution catheter



Continuous registration of blood velocity and cardiac output with a hot-film anemometer probe, mounted on a Swan-Ganz thermodilution catheter



European Surgical Research. Europaische Chirurgische Forschung. Recherches Chirurgicales Europeennes 13(5): 376-386



In order to construct a catheter, capable of monitoring cardiac output, a specially designed double-conical hot-film anemometer probe was fastened at the tip of a Swan-Ganz thermodilution catheter. Common sources of error for most catheter velocity probes include difficult calibration, unknown velocity profile at the point of measurement and unknown position of the probe in this profile. By using mongrel dogs and in order to exclude these sources of error, the intermittent thermodilution method was used to in vitro calibrate the hot-film anemometer, which registered velocity continuously. A mean correlation coefficient between these two methods was found to be 0.886. A mean line of regression between thermodilution (abscissa) and anemometer (ordinate) had a slope of 0.796 +/- 0.223 (+/- SD) and a y-intercept of 24 +/- 14 ml/min/kg. The slope was significantly lower than one (t test, p less than 0.05) and the y-intercept significantly larger than zero (t test, p less than 0.02). As a control of the thermodilution method, electromagnetic flow in the ascending aorta was registered and a mean correlation coefficient of 0.967 found. The hot-film sensor itself can be used as thermodilution method with the hot-film anemometer's continuous registration of velocity.

(PDF emailed within 1 workday: $29.90)

Accession: 042667573

Download citation: RISBibTeXText

PMID: 6459935



Related references

Monitoring cardiac output with a new hot film anemometer probe mounted on a swan ganz thermo dilution catheter. Artificial Organs 5(2): 208, 1981

A hot-film anemometer probe mounted on a Swan-Ganz thermodilution catheter: a preliminary report. Clinical Physics and Physiological Measurement 2(1): 49-52, 1981

Comparison between pulse-indicated continuous cardiac output catheter and Swan-Ganz catheter in evaluating blood volume. Zhongguo Wei Zhong Bing Ji Jiu Yi Xue 24(8): 495-496, 2013

An evaluation of thermodilution cardiac output measurement using the Swan-Ganz catheter. Anaesthesia and Intensive Care 9(3): 208-220, 1981

Application of the Swan-Ganz catheter and thermodilution cardiac output measurement in cardiac surgery. Kyobu Geka. Japanese Journal of Thoracic Surgery 29(9): 612-617, 1976

Quick fix of bent prongs of the thermodilution cardiac output connector of a Swan-Ganz catheter. Journal of Clinical Anesthesia 17(5): 407-408, 2005

Comparison of thermodilution cardiac output measurements by injection of the proximal lumen versus side port of the Swan-Ganz catheter. Heart & Lung 14(2): 126-127, 1985

Some aspects of the clinical use of thermodilution in measuring cardiac output. With particular reference to the Swan-Ganz thermodilution catheters. Scandinavian Journal of Clinical and Laboratory Investigation 38(4): 383-388, 1978

Comparison of the Efficacy of Continuous Cardiac Output Swan-Ganz-Catheter, Pulse Contour Analysis and Transesophageal Echocardiography during OPCAB Surgery. Anesthesiology Abstracts of Scientific Papers Annual Meeting ( ): Abstract No A-216, 2003

Usefulness of the Swan-Ganz pacing thermodilution catheter for patients with cardiac disease. Masui. Japanese Journal of Anesthesiology 34(6): 837-841, 1985

Usefulness of swan ganz pacing thermodilution catheter for patients with cardiac disease. Japanese Journal of Anesthesiology 34(6): 837-841, 1985

Assessment of the sterility of long-term cardiac catheterization using the thermodilution Swan-Ganz catheter. Chest 74(4): 377-380, 1978

Comparison of thermodilution cardiac outputs obtained from a centrally placed introducer sheath and from the right atrial port of a swan ganz catheter. Circulation 78(4 PART 2): II2, 1988

Is the cardiac output obtained from a Swan-Ganz catheter always zero?. Journal of Clinical Monitoring and Computing 22(6): 431-433, 2008