Indirect fluorescent antibody tests for parasitic diseases. 3. Conjugate-antigen relationships in the tests for trichinosis and schistosomiasis
Sulzer, A.J.; Kagan, I.G.
American Journal of Medical Technology 33(3): 192-199
1967
ISSN/ISBN: 0002-9335 PMID: 5342610 Accession: 043382395
Full Text Article emailed within 1 workday
Payments are secure & encrypted

Related References
Sulzer, A.J.; Kagan, I.G. 1967: Indirect fluorescent antibody tests for parasitic diseases: III. Conjugate-antigen relationships in the tests for trichinosis and schistosomiasis American Journal Medicine Technol 33(3): 192-199Sulzer, A.J. 1965: Indirect fluorescent antibody tests for parasitic diseases. I. Preparation of a stable antigen from larvae of Trichinella spiralis Journal of Parasitology 51(5): 717-721
Chisholm, A.J.S.andE.S. 1966: Comparison of the Ifa and Other Tests for Trichinella Spiralis Antibodies: Indirect Fluorescent Antibody Tests for Parasitic Diseases Public Health Reports 81(8): 729-734
Sulzer, A.; Chisholm, E.S. 1966: Indirect fluorescent antibody tests for parasitic diseases. Comparison of the IFA and other tests for Trichi-nella spiralis antibodies Publ. Hlth Rep, Wash., 81: 729-734
Sulzer, A.J.; Wilson, M.; Hall, E.C. 1969: Indirect fluorescent-antibody tests for parasitic diseases. V. An evaluation of a thick-smear antigen in the IFA test for malaria antibodies American Journal of Tropical Medicine and Hygiene 18(2): 199-205
Hall, E.C. 1969: Inst indirect fluorescent antibody tests for parasitic diseases v an evaluation of a thick smear antigen in the inst indirect fluorescent antibody test for malaria antibodies human plasmodium vivax plasmodium falciparum plasmodium brasilianum American Journal Of Tropical Medicine and Hygiene: 205
Sulzer, A.J.; Hall, E.C. 1967: Indirect fluorescent antibody tests for parasitic diseases: IV. Statistical study of variation in the indirect fluorescent antibody test for toxoplasmosis American Journal Epidemiol 86(2): 401-407
Sulzer, A.J.; Hall, E.C. 1967: Indirect fluorescent antibody tests for parasitic diseases. IV. Statistical study of variation in the indirect fluorescent antibody (IFA) test for toxoplasmosis American Journal of Epidemiology 86(2): 401-407
Sulzer, A.J.; Hall, E.C.; Wilson, M. 1969: Indirect Fluorescent-Antibody Tests for Parasitic Diseases The American Journal of Tropical Medicine and Hygiene 18(2): 199-205
McCarten, W.G.; Nzelibe, F.K. 1975: Schistosomiasis: evaluation of the indirect fluorescent antibody, complement fixation, and slide flocculation tests in screening for schistosomiasis Experimental Parasitology 37(2): 239-250
Belozerov, S.N. 1975: Diagnosis of trichinosis in live pigs (indirect fluorescent antibody and ring precipitation tests) Veterinariia (6): 70-72
Weiss, N.; Stürchler, D.; Dietrich, F.M. 1978: Radioallergosorbent and indirect fluorescent antibody tests in immunodiagnosis of schistosomiasis Lancet 2(8102): 1231-1233
Agarwal, S.S.; Sharma, P.; Nath, A.; Srivastava, I.K.; Rai, J.; Dutta, G.P. 1981: Indirect haemagglutination and indirect fluorescent antibody tests for human malaria using Plasmodium knowlesi antigen Indian Journal of Malariology 18(2): 67-72
Foster, R. 1965: Skin Antigen tests and the Fluorescent Antibody Technique in the Diagnosis of Schistosomiasis East African Medical Journal 42: 117-121
Zítová, D.; Jíra, J.; Princová, D. 1973: Indirect fluorescent antibody and complement fixation tests: simultaneous serological tests for toxoplasmosis Ceskoslovenska Epidemiologie Mikrobiologie Imunologie 22(2): 88-94
Del Rey Calero, J.; Kagan, I.G.; Sulzier, A.J. 1967: Comparative study of the types of antibodies that participate in the indirect fluorescent antibody and other diagnostic tests used in identifying schistosomiasis cercarial slide flocculation test human Revista Iberica de Parasitologia 27(1/2): 63-71
Sadun, E.H.; Gore, R.W.; Wellde, B.T.; Clyde, D.F. 1969: Malarial antibodies in human volunteers. a comparison of the soluble antigen fluorescent antibody (SAFA) and the indirect hemagglutination (IHA) tests using as antigen Plasmodium falciparum parasitized erythrocyte lysates Military Medicine 134(10): 1294-1299
Bhardwaj, O.P.; Shriniwas; Balkrishnan, K. 1982: Comparison of soluble antigen fluorescent antibody test with indirect haemagglutination tests in serodiagnosis of tuberculosis Indian Journal of Pathology and Microbiology 25(1): 70-77
Newhouse, V.F.; Shepard, C.C.; Redus, M.D.; Tzianabos, T.; McDade, J.E. 1979: A comparison of the complement fixation, indirect fluorescent antibody, and microagglutination tests for the serological diagnosis of rickettsial diseases American Journal of Tropical Medicine and Hygiene 28(2): 387-395
Wilson, M.; Sulzer, A.J.; Rogers, W.A.; Fried, J.A.; Mathews, H.M. 1971: Comparison of the indirect-fluorescent antibody and indirect-hemagglutination tests for malarial antibody American Journal of Tropical Medicine and Hygiene 20(1): 6-9