Accuracy evaluation of a method to partition ground reaction force and center of pressure in cane-assisted gait using an instrumented cane with a triaxial force sensor



Accuracy evaluation of a method to partition ground reaction force and center of pressure in cane-assisted gait using an instrumented cane with a triaxial force sensor



Gait and Posture 60: 141-147



Clarifying the biomechanics of cane-assisted gait in elderly individuals and patients with gait disorders is important for developing better therapeutic interventions in the fields of rehabilitation and orthopedics. However, if the foot and the cane in the ipsilateral hand are placed on the same force plate simultaneously, the force plate cannot separate the forces as it records the sum of the forces. To overcome this indeterminacy problem of the ground reaction force (GRF) and the center of pressure (COP) in cane-assisted gait analysis, a method to partition the GRF and COP using an instrumented cane with a force transducer has been proposed. However, the accuracy and precision of the estimated GRF and COP has not been evaluated previously. We therefore reestablished a framework to partition the foot and cane forces during walking using an instrumented cane with a triaxial force sensor and evaluated the accuracy and precision of the method using a force plate array. Cane-assisted gait of healthy adults and hemiplegic patients were measured. Mean accuracy and precision associated with the GRF and COP measurements were approximately 0.4±1.4N and 0.2±2.7mm, respectively, indicating that the separations of the GRF and COP were sufficiently accurate for kinetic gait analysis. Although some methodological limitations certainly apply, this system will serve as a useful tool for improved therapeutic interventions.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 043740275

Download citation: RISBibTeXText

PMID: 29207289

DOI: 10.1016/j.gaitpost.2017.11.022


Related references

Accuracy evaluation of a method to partition ground reaction force and center of pressure in cane-assisted gait using an instrumented cane with a triaxial force sensor. Gait & Posture 60: 141-147, 2018

Effects of a cane on floor reaction force and center of force during gait. Clinical Orthopaedics and Related Research 2000(375): 313-319, 2000

New method for assessment of gait variability based on wearable ground reaction force sensor. Conference Proceedings 2008: 2341-2344, 2008

The effect of center of pressure alteration on the ground reaction force during gait: A statistical model. Gait and Posture 66: 107-113, 2018

Temporal stride and force analysis of cane-assisted gait in people with hemiplegic stroke. Archives of Physical Medicine and Rehabilitation 82(1): 43-48, 2001

A method for the reconstruction of ground reaction force-time characteristics during gait from force platform recordings of simultaneous foot falls. IEEE Transactions on Bio-Medical Engineering 47(4): 547-551, 2000

Design of an Artificial Neural Network Algorithm for a Low-Cost Insole Sensor to Estimate the Ground Reaction Force (GRF) and Calibrate the Center of Pressure (CoP). Sensors 18(12):, 2018

Greater peak vertical ground reaction force and vertical ground reaction force loading rate during walking gait are associated with a lower serum ratio of collagen turnover in individuals with anterior cruciate ligament reconstruction. Osteoarthritis and Cartilage 23: A108-A109, 2015

A wearable ground reaction force sensor system and its application to the measurement of extrinsic gait variability. Sensors 10(11): 10240-10255, 2010

Ground reaction force profiles from force platform gait analyses of clinically normal mesomorphic dogs at the trot. American Journal of Veterinary Research 55(6): 756-761, 1994

Treadmill motor current based anteroposterior force estimation using ground reaction force approximation depending on gait cycle. Conference Proceedings 2011: 1583-1589, 2011

Validation of an ear-worn sensor for gait monitoring using a force-plate instrumented treadmill. Gait and Posture 35(4): 674-676, 2012

Accuracy and precision of loadsol ® insole force-sensors for the quantification of ground reaction force-based biomechanical running parameters. European Journal of Sport Science 18(8): 1100-1109, 2018

Inverse dynamics calculations during gait with restricted ground reaction force information from pressure insoles. Gait and Posture 23(2): 189-199, 2006

Evaluation of force data with a force/torque sensor during FESS. A step towards robot-assisted surgery. Hno 56(8): 789-794, 2008