+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Reproducibility of expired breath hydrogen levels in the neonate: a comparison of two methods for sample collection



Reproducibility of expired breath hydrogen levels in the neonate: a comparison of two methods for sample collection



Clinica Chimica Acta; International Journal of Clinical Chemistry 127(3): 337-342



We have compared a nasopharyngeal catheter method for breath sampling and a valved collection device. Sample quality was assessed by simultaneous oxygen measurement and reproducibility was checked by the analysis of 50 pairs of samples from four premature neonates. Both collection methods produced samples of highly variable quality suggesting a variable mixture of alveolar and non-alveolar air as well as differences in expired oxygen levels between babies. The mean oxygen levels were similar for both sampling techniques. Linear regression analysis of paired hydrogen results showed a highly significant correlation coefficient r = 0.73. This was improved markedly to r = 0.94 by normalization of hydrogen values based on observed oxygen levels, and so supports the earlier article by Robb and Davidson [1]. All breath hydrogen analyses require a measure of sample quality. Reproducible results and meaningful changes in hydrogen concentration in breath samples can only be achieved by correction according to sample quality. Correction to a common oxygen value should allow quantitative comparisons between patients. Samples were best collected from neonates by the nasopharyngeal catheter method, which least disturbed the patient, allowed multiple sample collection and gave lower oxygen and higher hydrogen values where large differences between pairs occurred.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 044207170

Download citation: RISBibTeXText

PMID: 6839488

DOI: 10.1016/0009-8981(83)90160-2


Related references

Reproducibility of expired breath hydrogen levels in the neo nate a comparison of 2 methods for sample collection. Clinica Chimica Acta 127(3): 337-342, 1983

Expired breath hydrogen levels in the neo nate methods of collection and reproducibility of results. Australian Paediatric Journal 17(3): 235, 1981

Advances in breath hydrogen quantitation in paediatrics: sample collection and normalization to constant oxygen and nitrogen levels. Clinica Chimica Acta; International Journal of Clinical Chemistry 111(2-3): 281-285, 1981

A new method of expired gas collection for the measurement of breath hydrogen (H2) in infants and small children. Acta Paediatrica Scandinavica 77(1): 55-59, 1988

Elevated levels of expired breath hydrogen peroxide in bronchiectasis. American Journal of Respiratory and Critical Care Medicine 158(3): 991-994, 1998

Cigarette smoking does not increase hydrogen peroxide levels in expired breath condensate of patients with stable COPD. Monaldi Archives for Chest Disease 53(3): 268-273, 1998

Measuring of end-expired breath ethanol concentration following percutaneous ethanol injections (PEI) carried out on patients suffering from hepatocellular Carcinoma - A comparison between venous and arterial ethanol concentrations and end-expired breath depends on the measuring instrument. Blutalkohol 42(6): 421-430, 2005

A Comparison Of Tidal And Incentive Breath Collection Methods For The Determination Of Breath Volatiles Concentration. Emergency Medicine Journal 32(12): 983.1-983, 2015

Improvement of carbon 14 triolein breath test efficacy by measuring expired carbon dioxide prolonging duration of breath sample collections. Gastroenterology 96(5 Part 2): A525, 1989

Comparison of abdominal bloating severity between Irritable Bowel Syndrome patients with high and low levels of breath hydrogen excretion in a lactulose breath test. Revista de Gastroenterologia de Mexico 77(2): 53-57, 2013

Human breath analysis: methods for sample collection and reduction of localized background effects. Analytical and Bioanalytical Chemistry 396(2): 739-750, 2010

The collection and analysis of endogenous organic constituents found in expired rat breath. Abstracts of Papers American Chemical Society 201(1-2): ANYL 166, 1991

A analysis of the optimal timing of breath sample collection in the 13C-urea breath test. Gastroenterology 110(4 Suppl. ): A273, 1996

Comparison of two methods for exhaled breath condensate collection. Allergy 61(8): 1016-1018, 2006

Carbon-13 urea breath test for Helicobacter pylori Optimal timing of breath sample collection. Gastroenterology 104(4 Suppl. ): A45, 1993