+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

A new curved peel-away sheath for central venous catheter placement



A new curved peel-away sheath for central venous catheter placement



Cardiovascular and Interventional Radiology 16(2): 117-118



A new 10F peel-away sheath with a preformed curve is now available. The procedure for insertion of central venous catheters remains the same, with the new curved sheath replacing the straight version. In our experience, this modification facilitates the placement of central venous catheters and decreases the incidence of catheter tip malposition and kinking.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 045079762

Download citation: RISBibTeXText

PMID: 8485741

DOI: 10.1007/bf02602993


Related references

Re: A new curved peel-away sheath for central venous catheter placement: technical note. Cardiovascular and Interventional Radiology 17(6): 356-356, 1994

Preventing kinking of the peel-away sheath during insertion of a long term central venous catheter using percutaneous subclavicular venipuncture. Surgery, Gynecology & Obstetrics 172(2): 148-150, 1991

Management of inadvertent carotid artery sheath insertion during central venous catheter placement. JAMA Surgery 148(11): 1063-1066, 2014

Comparison of direct insertion and sheath-avulsion method in the placement of cuffed central venous catheter. Zhongguo Wei Zhong Bing Ji Jiu Yi Xue 24(3): 182-183, 2013

Internal jugular vein duplication with absent carotid sheath detected during ultrasound-guided pediatric central venous catheter placement. Journal of Anesthesia 27(6): 972-973, 2014

'Peel away' long venous catheter technique minimizes placement steps. DVM 31(12): 3S, 2000

Abduction of Arm Facilitates Correction of Kinked Peel-Away Sheath During Subclavian Central Line Placement. Journal of Pediatric Surgery 50(12): 2164-2166, 2016

Topographical anatomy of central venous system in extremely low-birth weight neonates less than 1000 grams and the effect of central venous catheter placement. Clinical Anatomy 24(6): 711-716, 2011

Central venous access in oncology patients: the "peel-away" sheath for rapid insertion. Journal of Surgical Oncology 22(2): 81-83, 1983

Challenges associated with central venous catheter placement and central venous oxygen saturation monitoring. Respiratory Care 57(12): 2119-2123, 2013

Central venous catheter placement using the ECG-guided Cavafix-Certodyn SD catheter. Journal of Clinical Anesthesia 6(6): 469-472, 1994

Ultrasound assistance for central venous catheter placement in a pediatric emergency department improves placement success rates. Academic Emergency Medicine 21(9): 981-986, 2014

The supraclavicular fossa ultrasound view for central venous catheter placement and catheter change over guidewire. Journal of Visualized Experiments 94): -, 2016

Accuracy of central venous catheter tip placement with two different catheter lengths. Anaesthesia 65(7): 757-758, 2010

Exclusion of neutropenic children from implanted central venous catheter placement: impact on early catheter removal. Journal of Pediatric Surgery 45(6): 1115-1119, 2010