+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Beam characteristics and clinical possibilities of a new compact treatment unit design combining narrow pencil beam scanning and segmental multileaf collimation



Beam characteristics and clinical possibilities of a new compact treatment unit design combining narrow pencil beam scanning and segmental multileaf collimation



Medical Physics 25(12): 2358-2369



Not until the last decade has flexible intensity modulated three-dimensional dose delivery techniques with photon beams become a clinical reality, first in the form of heavy metal transmission blocks and other beam compensators, then in dynamic and segmented multileaf collimation, and most recently by scanning high-energy narrow electron and photon beams. The merits of various treatment unit and bremsstrahlung target designs for high-energy photon therapy are investigated theoretically for two clinically relevant target sites, a cervix and a larynx cancer both in late stages. With an optimized bremsstrahlung target it is possible to generate photon beams with a half-width of about 3 cm at a source to axis distance (SAD) of 100 cm and an initial electron energy of 50 MeV. By making a more compact treatment head and shortening the SAD, it is possible to reduce the half-width even further to about 2 cm at a SAD of 70 cm and still have sufficient clearance between the collimator head and the patient. One advantage of a reduced SAD is that the divergence of the beam for a given field size on the patient is increased, and thus the exit dose is lowered by as much as 1%/cm of the patient cross section. A second advantage of a reduced SAD is that the electron beam on the patient surface will be only about 8 mm wide and very suitable for precision spot beam scanning. It may also be possible to reduce the beamwidth further by increasing the electron energy up to about 60 MeV to get a photon beam of around 15 mm half-width and an electron beam as narrow as 5 mm. The compact machine will be more efficient and easy to work with, due to the small gantry and the reduced isocentric height. For a given target volume and optimally selected static multileaf collimator, it is no surprise that the narrowest possible scanned elementary bremsstrahlung beam generates the best possible treatment outcome. In fact, by delivering a few static field segments with individually optimized scan patterns, it is possible to combine the advantage of being able to fine tune the fluence distribution by the scanning system with the steeper dose gradients that can be delivered by a few static multileaf collimator segments. It is demonstrated that in most cases a few collimator segments are sufficient and often a single segment per beam portal may suffice when narrow scanned photon beams are employed, and they can be delivered sequentially with a negligible time delay. A further advantage is the increase of therapeutically useful photons and improved patient protection, since the pencil beam is only scanned where the leaf collimator is open. Consequently, some of the problems associated with dynamic multileaf collimation such as the tongue and groove and edge leakage effects are significantly reduced. Fast scanning beam techniques combined with good treatment verification systems allow interesting future possibilities to counteract patient and internal organ motions in real time.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 045355146

Download citation: RISBibTeXText

PMID: 9874828

DOI: 10.1118/1.598446


Related references

Simultaneous optimization of dynamic multileaf collimation and scanning patterns or compensation filters using a generalized pencil beam algorithm. Medical Physics 22(7): 1141-1156, 1995

Generation of arbitrary intensity profiles by combining the scanning beam with dynamic multileaf collimation. Medical Physics 23(1): 1-8, 1996

Multileaf collimation of electrons--clinical effects on electron energy modulation and mixed beam therapy depending on treatment head design. Physics in Medicine and Biology 47(7): 1013-1024, 2002

Contour scanning, multi-leaf collimation and the combination thereof for proton pencil beam scanning. Physics in Medicine and Biology 64(1): 015002, 2018

A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams. Medical Physics 43(3): 1462-1472, 2016

Pencil Beam Scanning (PBS) Proton Therapy in a Fixed-Beam Room for Treatment of Pediatric Brain Tumors. International Journal of Radiation Oncology*biology*physics 87(2): S592-S593, 2013

Proton therapy posterior beam approach with pencil beam scanning for esophageal cancer : Clinical outcome, dosimetry, and feasibility. Strahlentherapie und Onkologie 192(12): 913-921, 2016

Impact of Spot Size and Beam-Shaping Devices on the Treatment Plan Quality for Pencil Beam Scanning Proton Therapy. International Journal of Radiation Oncology Biology Physics 95(1): 190-198, 2016

Theoretical Benefits of Dynamic Collimation in Pencil Beam Scanning Proton Therapy for Brain Tumors: Dosimetric and Radiobiological Metrics. International Journal of Radiation Oncology Biology Physics 95(1): 171-180, 2016

Secondary Neutron Dose From a Dynamic Collimation System During Intracranial Pencil Beam Scanning Proton Therapy: A Monte Carlo Investigation. International Journal of Radiation Oncology Biology Physics 103(1): 241-250, 2019

Commissioning of the world's first compact pencil-beam scanning proton therapy system. Journal of Applied Clinical Medical Physics 19(1): 94, 2018

Proton pencil beam scanning for mediastinal lymphoma: the impact of interplay between target motion and beam scanning. Physics in Medicine and Biology 60(7): 3013-3029, 2015

Pencil Beam Scanning Proton Beam Chemoradiation Therapy With 5-Fluorouracil and Mitomycin-C for Definitive Treatment of Carcinoma of the Anal Canal: A Multi-institutional Pilot Feasibility Study. International Journal of Radiation Oncology Biology Physics 105(1): 90-95, 2019

Custom electron bolus treatment planning with skin collimation using the pencil-beam redefinition algorithm. International Journal of Radiation Oncology Biology Physics 57(2 Suppl.): S425, 2003

PO-0887: Pencil beam scanning using a new dedicated nozzle for proton beam delivery. RadioTherapy and Oncology 106: S343-S344, 2013