Effect of quantum mottle on radiographic image quality



Effect of quantum mottle on radiographic image quality



Radiologic Technology 67(5): 401-406



Any critique of radiographic image quality must include an evaluation of quantum mottle, a fundamental limitation of the imaging process. Using an illustrative analogy, this article explains the concept of quantum mottle and defines the quantum sink in an imaging chain. The article also describes the interdependence between quantum mottle and other system parameters, including spatial resolution, contrast resolution and total system speed.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 045889118

Download citation: RISBibTeXText

PMID: 8726986


Related references

Effect of quantum mottle and modulation transfer on the measurement of radiographic image quality. Proceedings of the Second Colloquium on Diagnostic Radiologic Instrumentation: Modulation transfer function, Chicago, Ill , April, 1964 350-369, 1965

Effect of image sharpening on radiographic image quality. Journal of Prosthetic Dentistry 120(6): 927-933, 2018

The dependence of radiographic mottle on beam quality. Ajr. American Journal of Roentgenology 127(5): 819-824, 1976

The Effect of some Physical Factors on Radiographic Image Quality. Radiology 84: 123-124, 1965

Effect of crossover exposure on radiographic image quality of screen-film systems. Radiology 139(3): 707-714, 1981

Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography. Medical Physics 29(8): 1643-1650, 2002

Dual-film cassette technique for studying the effect of radiographic image quality on diagnostic accuracy. Medical Physics 11(5): 646-652, 1984

Loss of image quality due to the image output of a digital radiographic system. Zeitschrift für Medizinische Physik 19(1): 67-72, 2009

Benchmarking the performance of fixed-image receptor digital radiographic systems part 1: a novel method for image quality analysis. Australasian Physical and Engineering Sciences in Medicine 39(2): 453-462, 2016

A Case Study into the Effect of Radiographic Factors on Image Quality and Dose for a Selenium Based Digital Chest Radiography System. Radiation Protection Dosimetry 80(1): 279-282, 1998

Comparison of image quality obtained with optical and radiographic magnification techniques in fine-detail skeletal radiography: effect of object thickness. Radiology 118(1): 189-195, 1976

Penetration quality measurement for standardization of radiographic image quality. Medical Physics 2(1): 5-8, 1975

Nonlinear Effect on Noise Power Spectrum for Quantum Mottle in Radiographs. Igaku Butsuri 20(2): 83-94, 2000

Quality criteria of the radiographic image. L' Information Dentaire 66(17): 1715-1716, 1984

Evaluation of radiographic image quality. Investigative Radiology: 429-430, 1972