Efficiency transfer and coincidence summing corrections for gamma-ray spectrometry



Efficiency transfer and coincidence summing corrections for gamma-ray spectrometry



Applied Radiation and Isotopes 52(3): 791-795



ETNA (Efficiency Transfer for Nuclide Activity measurements) is a new computer program providing both detector efficiency transfer for various types of sources for coaxial source-detector geometries and coincidence summing corrections. This program, available for use on PCs, has a direct link to the computerised database NUCLEIDE in order to automatically import the necessary radionuclide decay data. The specific features and facilities are outlined and examples are given.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 045930079

Download citation: RISBibTeXText

PMID: 10724442


Related references

Monte Carlo calculation of the efficiency calibration curve and coincidence-summing corrections in low-level gamma-ray spectrometry using well-type HPGe detectors. Applied Radiation and Isotopes 53(1-2): 57-62, 2000

Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry. AppliedRadiationandIsotopes68(7-8):1407, 2010

Coincidence summing corrections for the natural decay series in gamma-ray spectrometry. Applied Radiation and Isotopes 54(5): 769-776, 2001

Accurate computation of coincidence summing corrections in low level gamma-ray spectrometry. Applied Radiation and Isotopes 53(1-2): 51-56, 2000

Experimental assessment of the coincidence summing corrections in gamma-ray spectrometry of bulk samples. Applied Radiation and Isotopes 83 Pt A: 1-7, 2014

Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry--part II (volume sources). Applied Radiation and Isotopes 70(9): 2112-2118, 2012

Simplified methods for coincidence summing corrections in HPGe efficiency calibration. Applied Radiation and Isotopes 70(9): 2161-2163, 2012

Summing-coincidence corrections with Geant4 in routine measurements by γ spectrometry of environmental samples. Applied Radiation and Isotopes 87: 390-393, 2014

True coincidence-summing corrections for the coincident gamma-rays measured with coplanar grid CdZnTe detectors. Applied Radiation and Isotopes 68(6): 1040-1048, 2010

Coincidence summing correction in gamma spectrometry. Science of the Total Environment 130-131: 167-175, 1993

A simplified technique to determine random coincidence summing of gamma rays and dead time count loss corrections. Applied Radiation and Isotopes 82: 72-74, 2013

Coincidence summing effects in gamma-ray spectrometry using a Marinelli beaker. Applied Radiation and Isotopes 66(6-7): 799-803, 2008

Calculation of coincidence summing in gamma-ray spectrometry with the EGS5 code. Applied Radiation and Isotopes 95: 53-58, 2015

Coincidence-summing in gamma-ray spectrometry by excitation of matrix X-rays. Applied Radiation and Isotopes 52(3): 725-732, 2000

Fast procedures for coincidence-summing correction in gamma-ray spectrometry. Applied Radiation and Isotopes 52(3): 745-752, 2000