Evaluation of external dose equivalent with thermoluminescent dosimeters from residents living in radiation-contaminated buildings



Evaluation of external dose equivalent with thermoluminescent dosimeters from residents living in radiation-contaminated buildings



Applied Radiation and Isotopes 48(9): 1237-1243



As of October 1996 there are more than 90 radiation-contaminated steel supported rebar buildings (containing more than 1000 apartments) dispersed in the northern part of Taiwan. These apartments were contaminated with cobalt-60 at a total activity ranging from 1-140 microSv/yr. In this paper, a method is developed for evaluating external dose equivalent and dose equivalent rates encountered by the residents wearing specially designed thermoluminescent dosimeter (TLD)-embedded chains, belts and badges. Comparisons are also made between the TLD readings and the exposure readings from indoor layout personal dosimetry surveys and room occupancy adjustments to the buildings. The accuracy and sensitivity of the TLDs compared with the ionization chamber readings are judged to be considerable improvements over those of previous studies. From the present study, it is concluded that the reliability of the daily activity records provided by the residents during the entire TLD-wearing period is the most critical but challenging feature of the external dose equivalent measurement.

(PDF emailed within 1 workday: $29.90)

Accession: 046009713

Download citation: RISBibTeXText

PMID: 9418211


Related references

Preliminary study of dose equivalent evaluation for residents in radioactivity contaminated rebar buildings. Applied Radiation and Isotopes 49(12): 1641-1647, 1998

Dose reconstruction for residents living in 60Co-contaminated rebar buildings. Health Physics 74(6): 707-713, 1998

Radiation surveys and dose equivalent assessments for 60Co-contaminated rebar buildings. Applied Radiation and Isotopes 56(6): 901-906, 2002

Use of thermoluminescent dosimeters for measurement of external radiation in Guarapari, Brazil. Health Physics 12(7): 970-971, 1966

Effect of prolonged radiation exposure on the thyroid gland of residents living in 60Co-contaminated rebar buildings. International Journal of Radiation Biology 77(11): 1117-1122, 2001

Radiation dose and energy control in radiation therapy using mailable thermoluminescent dosimeters. Meditsinskaia Radiologiia 23(10): 52-55, 1978

Estimation of organ dose equivalents from residents of radiation-contaminated buildings with Rando phantom measurements. Applied Radiation and Isotopes 50(5): 867-873, 1999

Effect of dose on the energy dependence of LiF thermoluminescent radiation dosimeters. Radiat Bot 7(1): 1-5, 1967

Thermoluminescent dosimeters for in vivo measurement of radiation exposure and related dose in mammography. Radiologic Technology 53(5): 383-392, 1982

Evaluation of dose variation during total skin electron irradiation using thermoluminescent dosimeters. International Journal of Radiation Oncology, Biology, Physics 33(2): 475-478, 1995

Estimating dose to implantable cardioverter-defibrillator outside the treatment fields using a skin QED diode, optically stimulated luminescent dosimeters, and LiF thermoluminescent dosimeters. Medical Dosimetry 37(3): 334-338, 2013

External radiation exposure of residents living close to the Mayak facility: main sources, dose estimates, and comparison with earlier assessments. Radiation and Environmental Biophysics 43(2): 127-139, 2004

Chromosome aberrations in lymphocytes of residents living in buildings constructed with radioactively contaminated rebars. Journal of Biomedical Science 8(5): 411-415, 2001

The effect of typical summertime ambient temperatures on lithium fluoride tissue-equivalent thermoluminescent dosimeters. Health Physics 68(6 SUPPL ): S66, 1995