Evaluation of five new liquid stable applications on the Roche Cobas Integra



Evaluation of five new liquid stable applications on the Roche Cobas Integra



European Journal of Clinical Chemistry and Clinical Biochemistry 35(11): 877-880



In the present study the analytical performances of five new liquid applications on the Roche Cobas Integra were evaluated: urea and high density lipoprotein (HDL) cholesterol in serum and glucose, creatinine and inorganic phosphorus in urine. The analytical evaluation consisted of imprecision, linearity and method comparison performed against either the actual Cobas Integra granulate applications or the corresponding methods on a Hitachi 704, according to the National Committee for Clinical Laboratory Standards protocols. Over 3700 results were obtained within 3 months. Average values of within-run and between-day coefficients of variation (CVs) were 1.15% and 1.48%, respectively, holding to a mean total CV of 2.17%. The linearity was excellent for all the five applications evaluated as the relative non-linearity was always within 1.53%, thus completely fulfilling the 2.5% upper limit. A strict correlation was observed by comparing results of 120 samples with either the corresponding granulate applications on Cobas Integra or the Hitachi reagents. Linear regression analysis of the results yielded correlation coefficients always above 0.987 and the slopes of the Passing & Bablok regression lines did not deviate by more than 7% from unity. No drift was observed over 4 hours of operations. In conclusion, the performance of these new Cobas Integra liquid applications, as demonstrated by the present study, proved them to be highly suitable for routine use in clinical laboratories.

(PDF emailed within 1 workday: $29.90)

Accession: 046009864

Download citation: RISBibTeXText

PMID: 9426348


Related references

Multicenter evaluation of the Roche Tinaquant a Transferrin Ver 2 immunoturbidimetric assay developed for use on all Roche Cobas Integra and BM/Hitachi analyzer systems. Clinical Chemistry 47(S6): A151, 2001

Method comparisons of Roche-TDM OnLine digoxin assay for COBAS MIRA and COBAS INTEGRA applications to Syva Emit 2000, Abbott TDx and Abbott AxSYM digoxin methods. Clinical Chemistry 42(6 PART 2): S210, 1996

Evaluation of specific serum proteins on the Roche COBAS INTEGRA. Clinical Chemistry 43(6 PART 2): S278, 1997

Evaluation of the Roche Cobas Integra HbA1c test from whole blood. Clinical Chemistry & Laboratory Medicine 37(SPEC SUPPL ): S396, 1999

Performance evaluation of the Roche Cyclosporine assay on the COBAS INTEGRA 700. Clinical Chemistry 45(6 PART 2): A125, 1999

An improved Roche-RP gentamicin assay utilizing a monoclonal antibody Applications to the COBAS FARA II and INTEGRA Analyzers. Clinical Chemistry 41(S6 PART 2): S111, 1995

Evaluation of specific serum protein assays on the Roche COBAS Integra. Clinical Chemistry 42(6 PART 2): S164, 1996

Evaluation of HbA1c on the Roche COBAS Integra 800 closed tube system. Clinical Biochemistry 40(11): 822-827, 2007

Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays. Journal of Clinical Microbiology 47(7): 2209-2217, 2009

Performance of the Roche Total Mycophenolic Acid® assay on the Cobas Integra 400®, Cobas 6000® and comparison to LC-MS/MS in liver transplant patients. Clinical Chemistry and Laboratory Medicine 49(7): 1159-1165, 2011

Performance evaluation of cobas HBV real-time PCR assay on Roche cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test. Clinical Chemistry and Laboratory Medicine 56(7): 1133-1139, 2018

Evaluation of the roche reagents for total and direct bilirubin on the roche cobas mira and cobas fara ii. Clinical Chemistry 38(6): 1045-1046, 1992

Evaluation of the roche reagent for magnesium on the roche cobas mira and cobas fara ii. Clinical Chemistry 38(6): 1045, 1992

Comparison of the Roche COBAS Amplicor Monitor, Roche COBAS Ampliprep/COBAS Taqman and Abbott RealTime Test assays for quantification of hepatitis C virus and HIV RNA. Clinical Chemistry and Laboratory Medicine 45(7): 917-922, 2007

Evaluation of the Unicel (TM) DXC 600 (Beckman Coulter) and comparison with Integra 800 (R) (Roche Diagnostics') FT Evaluation des performances analytiques du systeime Unicel (TM) DXC avec l'Integra 8000 (Roche diagnostics (R)). 2007