+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Evaluation of high density DRAMs as a nuclear radiation detector



Evaluation of high density DRAMs as a nuclear radiation detector



Applied Radiation and Isotopes 48(10-12): 1601-1604



The research is based on the nuclear radiation induced soft error phenomenon associated with dynamic random access memory devices (DRAMs). Samples of 256 kbit and 1 Mbit decapped DRAMs from several manufactures were exposed to standard alpha sources and showed a linear response with an intrinsic detection efficiency approaching 10%. Sensitivity studies were performed to evaluate the effects of DRAM operating voltage, refresh frequency and the data pattern stored prior to irradiation. The associated mechanism of soft error phenomenon is discussed. Samples were also exposed to gamma rays up to 10(5) rad to examine the total dose effect. The annealing phenomenon after gamma exposure is also presented.

(PDF emailed within 1 workday: $29.90)

Accession: 046010320

Download citation: RISBibTeXText

PMID: 9463880


Related references

Comparison of processing methods to obtain accurate bulk density compensation and azimuthal density images from dual-detector gamma density measurements in high angle and horizontal wells. Petrophysics (Houston, Tex), 2008

Comparison of radiation dose estimates and scan performance in pediatric high-resolution thoracic CT for volumetric 320-detector row, helical 64-detector row, and noncontiguous axial scan acquisitions. Academic Radiology 20(9): 1152-1161, 2013

Evaluation of a controlled drinking minimal intervention for problem drinkers in general practice (the DRAMS scheme). Journal of the Royal College of General Practitioners 37(301): 358-363, 1987

Comparison of radiation detector materials for imaging applications in nuclear medicine. Physics in Medicine and Biology 18(1): 120-132, 1973

Differences in mitochondrial and nuclear DNA status of high-density and low-density sperm fractions after density centrifugation preparation. Fertility & Sterility 79(Suppl 1): 754-762, March, 2003

Nuclear reactor pulse calibration using a CdZnTe electro-optic radiation detector. Applied Radiation and Isotopes 70(7): 1118-1120, 2012

Radiation effect on positronium formation in solid state nuclear track detector. Applied Radiation and Isotopes 65(3): 328-334, 2006

Mechanism to mount a collimator to a radiation detector of a nuclear medicine diagnostic apparatus us patent 4663531 may 5 1987. 1987

Characterisation of radiation field for irradiation of biological samples at nuclear reactor-comparison of twin detector and recombination methods. Radiation Protection Dosimetry 161(1-4): 196-200, 2015

Detector of high energy radiation on the structure Bi-4Ge-3O-12/ZnSe-xTe-1-x/ZnS. Nuclear Tracks & Radiation Measurements 21(1): 191-194, 1993

Evaluation of genetic alterations in inhabitants of a naturally high level background radiation and Kudankulam nuclear power project site in India. Asian Pacific Journal of Cancer Prevention 12(1): 35-41, 2012

High gamma-ray dose measurement using nuclear track detector. Radiation Protection Dosimetry 140(3): 218-222, 2010

Precise dose evaluation using a commercial phototransistor as a radiation detector. Radiation Protection Dosimetry 120(1-4): 60-63, 2006

A limited evaluation of Cicoil "Personal RF Radiation Hazard Detector". Health Physics 37(1): 171-174, 1979