Evaluation of image quality and spatial resolution of low-dose high-pitch multidetector-row helical high-resolution CT in 11 autopsy lungs and a wire phantom



Evaluation of image quality and spatial resolution of low-dose high-pitch multidetector-row helical high-resolution CT in 11 autopsy lungs and a wire phantom



Radiation Medicine 19(6): 279-284



The aim of this study was to evaluate whether low-dose high-pitch (6:1) multidetector-row helical high-resolution CT is appropriate for the evaluation of various pulmonary abnormalities, including faint opacities. Eleven autopsy lungs were scanned with a multidetector-row CT scanner using 2.5 mm x 4 beam collimation, effective slice thickness 3 mm, 6:1 pitch, 0.8 second gantry rotation speed, 20 cm Display FOV, high spatial frequency (bone) algorithm, and various radiation doses (120 kVp; 160, 80, 40, 24, and 8 mAs). The image quality of each CT set was assessed as adequate or inadequate for diagnosis by two independent observers. In addition, a wire phantom was scanned with the same parameters in order to describe the MTF curves. There was excellent agreement between the observers for the evaluation of image quality (kappa statistic, 0.84). The ratio of images evaluated as inadequate for 8 mAs and 24 mAs was significantly higher than that for 160, 80, and 40 mAs (p<0.01: chi-square test). MTF curves of both 8 and 24 mAs were significantly inferior to those of 40, 80, and 160 mAs (p<0.0 1, Friedman test), while the MTF curve of 40 mAs was relatively inferior to that of 160 mAs (p<0.05, Friedman test). More than 40 mAs in combination with 120 kVp is preferable for the evaluation of details of lung parenchyma by high-pitch. multidetector-row helical high-resolution CT.

(PDF emailed within 1 workday: $29.90)

Accession: 046010463

Download citation: RISBibTeXText

PMID: 11837577


Related references

High-resolution CT using multidetector CT equipment: evaluation of image quality in 11 cadaveric lungs and a phantom. Ajr. American Journal of Roentgenology 177(4): 875-879, 2001

Identification and characterization of focal ground-glass opacity in the lungs by high-resolution CT using thin-section multidetector helical CT: experimental study using a chest CT phantom. Radiation Medicine 26(1): 21-27, 2008

Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patients. European Radiology 20(5): 1188-1196, 2010

Image quality of high-resolution CT with 16-channel multidetector-row CT: comparison between helical scan and conventional step-shoot scan. Radiation Medicine 23(8): 539-544, 2006

Ultra-high resolution C-Arm CT arthrography of the wrist: Radiation dose and image quality compared to conventional multidetector computed tomography. European Journal of Radiology 89: 191-199, 2017

Multidetector spiral high-resolution computed tomography of the lungs: distribution of findings on coronal image reconstructions. Journal of Thoracic Imaging 17(4): 291-305, 2002

High pitch CT in triple rule-out studies: Radiation dose and image quality compared to multidetector CT. Radiologia 57(5): 412-418, 2017

Radiation dose reduction effects of prospective ECG-gated helical scan with high helical pitch in coronary multidetector computed tomography. Nihon Hoshasen Gijutsu Gakkai Zasshi 66(7): 774-780, 2010

Evaluation of general-purpose collimators against high-resolution collimators with resolution recovery with a view to reducing radiation dose in myocardial perfusion SPECT: A preliminary phantom study. Journal of Nuclear Cardiology 24(2): 596-604, 2016

High-pitch, 120 kVp/30 mAs, low-dose dual-source chest CT with iterative reconstruction: Prospective evaluation of radiation dose reduction and image quality compared with those of standard-pitch low-dose chest CT in healthy adult volunteers. Plos One 14(1): E0211097-E0211097, 2019

Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom. European Radiology 15(5): 1015-1026, 2005

Improvement of Image Quality in the Axial Section Using High-resolution Scan Mode and Hybrid Iterative Reconstruction in Ultra-high-resolution Computed Tomography. Nihon Hoshasen Gijutsu Gakkai Zasshi 74(12): 1419-1427, 2018

High resolution computerized tomography: dose evaluation with an anthropomorphic phantom. La Radiologia Medica 92(1-2): 110-113, 1996

High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose. International Journal of Cardiovascular Imaging 31(1): 125-133, 2015

Image quality and feasibility of an ultralow-dose high-pitch helical triple-rule-out computed tomography angiography acquired in the caudocranial direction. Journal of Thoracic Imaging 29(1): 50-59, 2014