+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Evaluation of initial surface apposition in porous-coated acetabular components



Evaluation of initial surface apposition in porous-coated acetabular components



Clinical Orthopaedics and Related Research 1993(293): 174-187



The initial surface apposition of the acetabular bone-implant interface was investigated for acetabular components of three different designs: hemispherical with spikes, hemispherical, and threaded hemispherical. Four acetabular components of each design were implanted into fresh anatomic specimen acetabula that were underreamed by 1 mm to the size of the component. Each acetabular specimen then was embedded in methylmethacrylate, sectioned, and examined under magnification. Although acetabular implantation was carefully performed by an experienced surgical team in an idealized laboratory environment, less than complete interface contact was achieved in most cases. Surface contact was limited by five factors: (1) bony anatomy, (2) asymmetric acetabular reaming, (3) retention of the subchondral plate, (4) acetabular component design, and (5) incorrect version of the acetabular component. The bony acetabulum is an incomplete hemisphere because of the acetabular notch and a deep acetabular fossa, and therefore cannot be machined to a perfect hemisphere. Asymmetric reaming occurs because of the anisotropic quality of bone. Retention of the subchondral plate causes incomplete seating of components with spikes or threads. The acetabular design determines the amount of porous coating available for bony apposition and varies depending on the surface area used for screw holes, apical holes, and thread segments. Increased, stable initial surface contact of acetabular components will increase the chances of stable biologic fixation. Improved surface contact will require changes in component design, instrumentation, and technique.

(PDF emailed within 0-6 h: $19.90)

Accession: 046010634

Download citation: RISBibTeXText

PMID: 8339478

DOI: 10.1097/00003086-199308000-00022


Related references

In vitro initial fixation of porous-coated acetabular total hip components. A biomechanical comparative study. Journal of Arthroplasty 4(3): 201-205, 1989

Bone ingrowth into porous coated canine acetabular replacements: the effect of pore size, apposition, and dislocation. Hip 1985: 214-234, 1985

Clinical and radiographic evaluation of non cemented porous coated acetabular components in total hip arthroplasty. Orthopaedic Transactions 11(1): 68, 1987

Tissue response to porous-coated implants lacking initial bone apposition. Journal of Arthroplasty 3(4): 337-346, 1988

The use of bilobed porous-coated acetabular components without structural bone graft for type III acetabular defects in revision total hip arthroplasty: a prospective study with a minimum 2-year follow-up. Journal of Arthroplasty 19(7): 867-873, 2004

Radiographic signs of osseointegration in porous-coated acetabular components. Clinical Orthopaedics and Related Research 444: 176-183, 2006

Postmortem analysis of bone growth into porous-coated acetabular components. Journal of Bone and Joint Surgery. American Volume 79(7): 1013-1022, 1997

Mechanical stability of porous-coated acetabular components in total hip arthroplasty. Journal of Arthroplasty 6(4): 295-300, 1991

Porous-coated acetabular components with screw fixation. Five to ten-year results. Journal of Bone and Joint Surgery. American Volume 78(7): 975-981, 1996

Histology of porous-coated acetabular components: 25 Cementless cups retrieved after arthroplasty. Acta Orthopaedica Scandinavica 64(6): 619-626, 1993

High placement of porous-coated acetabular components in complex total hip arthroplasty. Journal of Arthroplasty 9(4): 359-367, 1994

Bilobed oblong porous coated acetabular components in revision total hip arthroplasty. Clinical Orthopaedics and Related Research 2000(371): 154-160, 2000

A novel technique for the removal of well-fixed, porous-coated acetabular components with spike fixation. Journal of Arthroplasty 16(8): 1081-1083, 2001