+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Evaluation of the respicon as a personal inhalable sampler in industrial environments



Evaluation of the respicon as a personal inhalable sampler in industrial environments



Journal of Environmental Monitoring 4(5): 657-662



The Respicon has been introduced as a sampler for health related measurements of airborne contaminants at workplaces. The instrument is aimed at simultaneous collection of three health related aerosol fractions: (a) the coarser inhalable fraction, defining the aerosol fraction that may enter the nose and mouth during breathing; (b) the intermediate thoracic fraction, defining the fraction that may penetrate beyond the larynx and so reach the lung; and (c) the finer respirable fraction, defining the fraction that may penetrate to gas exchange region of the lung. The instrument has a number of features attractive to occupational hygienists: in addition to providing the three aerosol fractions simultaneously, it is light and compact enough to be used as a personal sampler. yet can be a tripod mounted for area sampling, it can provide samples not only for gravimetric analysis but also microscopic and chemical analyses; and it is also available in a photometric direct-reading version. The instrument has previously been evaluated as an area sampler and, in this mode of operation, has shown reasonable accuracy in collecting respirable, thoracic and inhalable particles, the latter up to particle diameters of ca. 80 microm. Except for some scattered unpublished data there exist no systematic investigations in the Respicon's performance when used as a personal sampler in the industrial environment. In this paper, we will report on a study of side by side comparison of the Respicon with the IOM inhalable sampler, regarded as a reference instrument for the inhalable fraction. The main study was performed at six different workplaces in a nickel refinery. Statistical analysis of the gravimetrically-determined concentration data reveals consistently lower aerosol exposure values for the Respicon as compared to the IOM sampler. The data for the nickel workplaces are compared with findings from other studies. The results are interpreted in the light of the overall results and the possibility of introducing a correction factor is discussed.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 046016429

Download citation: RISBibTeXText

PMID: 12400910


Related references

Evaluation of the Respicon?? as a personal inhalable sampler in industrial environmentsPresented at Airmon 2002, Lillehammer, Norway, 3???7 February 2002. Journal of Environmental Monitoring 4(5): 657-662, 2002

Performance of the RespiCon personal aerosol sampler in forest products industry workplaces. Aiha Journal 63(3): 311-316, 2002

A personal sampler for inhalable mixed-phase aerosols: Modification to an existing sampler and validation test with three pesticides. Chemosphere 28(6): 1135-1146, 1994

Performance characteristics of the button personal inhalable aerosol sampler. Aihaj 61(3): 398-404, 2000

A collaborative European study of personal inhalable aerosol sampler performance. Annals of Occupational Hygiene 41(2): 135-153, 1997

A Collaborative European Study Of Personal Inhalable Aerosol Sampler Performance. Annals of Occupational Hygiene 41(2): 135-153, 1997

Performance of the Button Personal Inhalable Sampler for the measurement of outdoor aeroallergens. Atmospheric Environment 37(34): 4723-4733, 2003

Design and computational fluid dynamics investigation of a personal, high flow inhalable sampler. Annals of Occupational Hygiene 54(4): 427-442, 2010

Applicability of a modified MCE filter method with Button Inhalable Sampler for monitoring personal bioaerosol inhalation exposure. Environmental Science and Pollution Research International 20(5): 2963-2972, 2013

Numerical Study of the RespiCon Sampler Performance in the Calm Air. Aerosol Science and Technology 48(1): 74-80, 2014

Development and evaluation of an inhalable bioaerosol manifold sampler. American Industrial Hygiene Association Journal 58(3): 196-206, 1997

Comparative study of an inhalable and a total dust sampler for personal sampling of dust and polycyclic aromatic hydrocarbons in the gas and particulate phase. Analyst 121(9): 1191-1196, 1996

Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery. Journal of Occupational and Environmental Hygiene 16(3): 250-257, 2019

Comparison of a Simplified and Full-Size Mannequin for the Evaluation of Inhalable Sampler Performance. Aerosol Science and Technology 35(1): 564-568, 2001

Correlation between urinary 1-hydroxypyrene and ambient air pyrene measured with an inhalable aerosol sampler and a total dust sampler in an electrode paste plant. Science of the Total Environment 212(1): 59-67, 1998