EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

G-suit inflation to 50 mmHg alters the cardiovascular transients when entering micro-G in parabolic flight



G-suit inflation to 50 mmHg alters the cardiovascular transients when entering micro-G in parabolic flight



Journal of Gravitational Physiology 1(1): P33-P34



In the present experiments it was decided to have each test-subject serve as his own control by fitting the test-subjects with a G-suit and comparing the condition of inflated G-suit to the normal situation. G-suit inflation was intended to only displace blood on the venous side of the circulation, not to increase total peripheral resistance. Therefore, a very modest inflation of 50 mmHg was applied. This was considered sufficient to expel most of the blood from the venous pool in abdomen and legs, even under the condition of increased G-loading in the pull-up phase. The parabolas were to be undergone in three body positions: standing upright, sitting and supine. The prediction of the experimental outcome was that we would find no difference between transients with and without G-suit inflation in the supine position, that an initial overshoot in pressure and stroke volume in the upright position would be very much damped by the G-suit, even more in the standing than in the sitting position. Studies were performed in 5 flights of NASA's KC-135, in January 1993. Per flight 40 parabolas were flown in an adapted 'roller coaster profile', i.e. 0-G phases were followed by a 2-G pull-out phase, after a very brief 1-G phase again followed by the next 2-G pull-up phase. This sequence was flown for 10 parabolas, then a 1-G horizontal flight period was inserted. The first 3 parabolas of each set of 10 the subjects were sitting upright, seat belt fastened. The next three they were standing, feet stuck under a load strap on the floor, stabilizing themselves by a grip on the ceiling. Then three parabolas were flown with the test-subject supine, loosely attached to the floor by a load strap and further aided by a grip to another strap on the floor. The last parabola of a set was used as 'spare' to repeat any failed maneuver.

(PDF emailed within 1 workday: $29.90)

Accession: 046141919

Download citation: RISBibTeXText

PMID: 11538754



Related references

Cardiovascular effects of anti-G suit inflation at 1 and 2 G. European Journal of Applied Physiology 94(3): 235-241, 2005

Acute and prolonged effects of G suit inflation on cardiovascular dynamics. Aerospace Medicine 40(1): 40-43, 1969

Effect of antigravity suit inflation on cardiovascular, PRA, and PVP responses in humans. Journal of Applied Physiology 61(2): 766-774, 1986

Antigravity suit inflation kidney function and cardiovascular and hormonal responses in men. Journal of Applied Physiology 66(2): 792-799, 1989

Cardiovascular and Valsalva responses during parabolic flight. Journal of Applied Physiology 85(5): 1957-1965, 1998

Cardiovascular function and gravity transitions during parabolic flight. Conference Proceedings 2007: 6673-6674, 2007

Cardiovascular autonomic adaptation in lunar and martian gravity during parabolic flight. European Journal of Applied Physiology 115(6): 1205-1218, 2016

Cardiovascular adaptations to parabolic flight in rats: a radio-telemetry feasibility study. Journal of Gravitational Physiology 4(2): P43-P44, 1997

Cardiovascular responses to repetitive exposure to hyper- and hypogravity states produced by parabolic flight. Journal of Clinical Pharmacology 34(5): 472-479, 1994

Body position and volume status as determinants of cardiovascular responses to transition into microgravity in parabolic flight. Physiologist 36(1 Suppl): S56-S57, 1993

Effect of antigravity suit inflation on cardiovascular plasma renin activity and plasma vasopressin responses in humans. Journal of Applied Physiology 61(2): 766-774, 1986

Preliminary investigation of cardiovascular responses to parabolic flight in sick and non sick individuals. Aviation Space & Environmental Medicine 60(5): 493, 1989

Micro stimulation alters saccadic eye movements in mid flight. Investigative Ophthalmology & Visual Science (SUPPL): 262, 1979

Circulatory response to recumbent exercise and head-up tilting in patients with disturbed sympathetic cardiovascular control Observations on the effect of norepinephrine infusion and antigravity suit inflation in the head-up tilted position. 1962

Flight behaviour of pigeons in the weightless phase of parabolic flight. Aviation, Space, and Environmental Medicine 46(5): 713-716, 1975