+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Host-bone response to porous-coated cobalt-chrome and hydroxyapatite-coated titanium femoral components in hip arthroplasty. Dual-energy x-ray absorptiometry analysis of paired bilateral cases at 5 to 7 years



Host-bone response to porous-coated cobalt-chrome and hydroxyapatite-coated titanium femoral components in hip arthroplasty. Dual-energy x-ray absorptiometry analysis of paired bilateral cases at 5 to 7 years



Journal of Arthroplasty 11(4): 429-437



Uncemented porous-coated cobalt-chrome femoral stems have produced satisfactory short-term clinical results, although slightly inferior to the results of cemented total hip arthroplasty. Proximal femoral bone resorption, osteolysis and fibrous ingrowth have been reported with porous-coated stems. Hydroxyapatite-coated stems and titanium stems have been introduced to avoid these findings through improved fixation. Dual-energy x-ray absorptiometry allows quantitative examination of bone density changes after uncemented total hip arthroplasty. This study examines the host-bone response to hydroxyapatite-coated titanium and porous-coated cobalt-chrome stems of identical geometry in three paired bilateral cases at 5 to 7 years. Distinctly different patterns of femoral bone mineral density changes were observed with the two stem designs. The authors conclude that dual-energy x-ray absorptiometry is a promising technique allowing noninvasive analysis of uncemented stem fixation, and that the data from this study suggest improved fixation and stress transfer with hydroxyapatite-coated titanium stems.

(PDF emailed within 0-6 h: $19.90)

Accession: 046274964

Download citation: RISBibTeXText

PMID: 8792250

DOI: 10.1016/s0883-5403(96)80033-7


Related references

Effect of hydroxyapatite-coated tibial components on changes in bone mineral density of the proximal tibia after uncemented total knee arthroplasty: a prospective randomized study using dual-energy x-ray absorptiometry. Journal of Arthroplasty 20(4): 516-520, 2005

Comparison of bone ingrowth into cobalt chrome sphere and titanium fiber mesh porous coated cementless canine acetabular components. Journal of Biomedical Materials Research 27(5): 639-644, 1993

Dual-energy X-ray absorptiometry measurement of bone mineral density around porous-coated cementless femoral implants. Methods and preliminary results. Journal of Bone and Joint Surgery. British Volume 75(2): 279-287, 1993

Intraoperative complications of revision hip arthroplasty using a fully porous-coated straight cobalt-chrome femoral stem. Journal of Arthroplasty 10 Suppl: S45-S51, 1995

Comparison of a highly porous titanium cup (Tritanium) and a conventional hydroxyapatite-coated porous titanium cup: A retrospective analysis of clinical and radiological outcomes in hip arthroplasty among Japanese patients. Journal of Orthopaedic Science 23(6): 967-972, 2018

Micromotion of femoral stems in total hip arthroplasty. A randomized study of cemented, hydroxyapatite-coated, and porous-coated stems with roentgen stereophotogrammetric analysis. Journal of Bone and Joint Surgery. American Volume 76(11): 1692-1705, 1994

Hydroxyapatite-coated femoral stem/porous-coated acetabulum survivorship at 15 years. Journal of Arthroplasty 26(6): 972-975, 2012

Comparing hydroxyapatite coated versus non hydroxyapatite coated femoral stems in primary total hip arthroplasty: a meta analysis of randomized controlled trial. Zhonghua Wai Ke Za Zhi 51(7): 645-650, 2015

Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Mid-Term Results in Metachronous Bilateral Total Hip Arthroplasty. Medical Principles and Practice 2019, 2019

Long term bone behavior in total primary hip arthroplasty with a fully hydroxyapatite-coated femoral stem: a continuous series of 120 cases with twelve years follow-up. Revue de Chirurgie Orthopedique et Reparatrice de l'Appareil Moteur 90(7): 628-635, 2004

Porous-coated femoral components with or without hydroxyapatite in primary uncemented total hip arthroplasty: a systematic review of randomized controlled trials. Archives of Orthopaedic and Trauma Surgery 129(9): 1165-1169, 2008

Implanting hydroxyapatite-coated porous titanium with bone morphogenetic protein-2 and hyaluronic acid into distal femoral metaphysis of rabbits. Chinese Journal of Traumatology 11(3): 179-185, 2008

Histological and mechanical comparison of hydroxyapatite-coated cobalt-chrome and titanium implants in the rabbit femur. Journal of Applied Biomaterials 6(4): 231-235, 1995

Effect of bone marrow grafting on the titanium porous-coated implant in bilateral total knee arthroplasty. Acta Orthopaedica 78(1): 116-122, 2007

Postmortem comparative analysis of titanium and hydroxyapatite porous-coated femoral implants retrieved from the same patient. A case study. Journal of Arthroplasty 8(2): 203-211, 1993