+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

How much are external fixator nuts tightened in general practice



How much are external fixator nuts tightened in general practice



Aktuelle Traumatologie 23(4): 212-213



External fixation is an approved system of treatment in orthopedic surgery. 21 different modalities of assembly--using the AO (ASIF) tubular system--were selected for a clinical trial in 3 major trauma hospitals. It is considered that all nuts of the applied external fixators were tightened properly. In experimental work it was found, that a torque of 8-11 Nm is sufficient and can be recommended. A suitable torque-wrench is available.

(PDF emailed within 1 workday: $29.90)

Accession: 046280050

Download citation: RISBibTeXText

PMID: 8101688


Related references

Stability of an external fixator made out of polymer materials - measurements on a model and comparison with a metal external fixator system. Hefte Zur Unfallheilkunde 138: 304-310, 1979

Comparison study on locking compress plate external fixator and standard external fixator for treatment of tibial open fractures. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi 27(11): 1291-1295, 2014

A novel external fixator of the hand: a practice pearl. Techniques in Hand & Upper Extremity Surgery 17(1): 57-59, 2013

Mechanical performance of hybrid Ilizarov external fixator in comparison with Ilizarov circular external fixator. Clinical Biomechanics 18(6): 518-522, July, 2003

Fracture stabilization with type II external fixator vs. type I external fixator with IM pin: finite element analysis. Veterinary and Comparative Orthopaedics and Traumatology 17(2): 91-96, 2004

CMC (Croatian Medical Corps) fixator - a new type of external fixator intended for war purposes. Periodicum Biologorum 95(1): 201-203, 1993

The use of an external skeletal fixator-intramedullary pin tie-in (ESF-IM fixator) for treatment of longbone fractures in raptors. Unknown, 2000

External fixator: surgical technique, pinless fixator, change in procedure. Helvetica Chirurgica Acta 60(6): 1073-1080, 1994

The Oxford External Fixator: fixator stiffness and the effects of bone pin loosening. Engineering in Medicine 14(1): 3-11, 29, 1985

Tensioning technique and fixator stability of a circular external fixator with threaded fine wires. Journal of Biomechanics 39(3): 544-550, 2006

Mathematical modeling of fixation of a bone fragment in a new Double-needle external Fixator compared to hoffmann ii fixator. Series on Biomechanics 23(1): 96-103, 2007

An engineering evaluation of the Oxford External Fixator with sliding clamps: fixator stiffness and fracture healing assessment. Engineering in Medicine 14(1): 21-29, 1985

Dynamic external fixator for pilon fractures of the proximal interphalangeal joints: a simple fixator for a complex fracture. Journal of Hand Surgery 28(2): 137-141, 2003

Stiffness of the AO spinal external fixator. Experimental results of stiffness of the AO spinal external fixator with 3 different pedicle screw systems. Zeitschrift für Orthopadie und Ihre Grenzgebiete 134(2): 177-184, 1996