How reliable is atrial sensing in single-lead VDD pacing: comparison of three systems



How reliable is atrial sensing in single-lead VDD pacing: comparison of three systems



Pacing and Clinical Electrophysiology 21(11 Pt 2): 2226-2231



This study evaluated the reliability of atrial sensing, expressed as AV synchronous stimulation, in three VDD systems with the atrial sensitivity (AS) programmed to a conventional value with a 2:1 safety margin compared to most-sensitive values. We studied 34 sex- and age-matched patients with 3 VDD systems: 14 with Unity 292-07, 10 with Saphir 600, and 10 with Thera VDD (5 model 8948 and 5 model 8968i). Two 24-hour Holters were performed on consecutive days. The AS was programmed in a randomized order to its most-sensitive value or to a 2:1 safety margin. All other parameters were programmed identically. The patients underwent a myopotential oversensing test and a daily life activity protocol. A beat-to-beat analysis of the Holters was performed to determine AV synchrony. For the entire group AV synchrony with conventional AS was 98.63% +/- 2.57%, compared to 99.80% +/- 0.43% with most-sensitive values (p = 0.002). There was no difference between the three systems with conventional AS. With the most-sensitive AS, AV synchrony was: Unity 99.99% +/- 0.03%, Saphir 99.42% +/- 0.60% (P = 0.002), Thera 99.81% +/- 0.35% (ns). In the Saphir system with an atrial blanking period of 150 ms, ventricular far-field sensing could be demonstrated in 5 of 10 patients. This reduced the percentage of AV synchrony due to an unwanted mode-switch to a nontracking mode. Myopotential oversensing was not detected in any patient. The VDD systems tested under identical conditions showed reliable P wave sensing at the most-sensitive atrial sensing setting without myopotential oversensing. Ventricular far-field sensing reduced AV synchrony and must be avoided by appropriate refractory periods.

(PDF emailed within 0-6 h: $19.90)

Accession: 046280961

Download citation: RISBibTeXText

PMID: 9825323

DOI: 10.1111/j.1540-8159.1998.tb01157.x


Related references

Atrial synchronous ventricular pacing with a single lead: reliability of atrial sensing during physical activities, and long-term stability of atrial sensing. Pacing and Clinical Electrophysiology 21(1 Pt 2): 271-276, 1998

Immediate and long-term atrial sensing stability in single-lead VDD pacing depends on right atrial dimensions. Europace 3(4): 324-331, 2001

Reliability of single-lead VDD atrial sensing and pacing during exercise. Pacing and Clinical Electrophysiology 22(12): 1747-1752, 2000

Atrial sensing and pacing with a single pass ventricular lead. Chinese Medical Journal 111(12): 1118-1123, 2001

Inappropriate atrial sensing in single lead VDD pacing How much is clinically relevant?. European Heart Journal 18(ABSTR SUPPL ): 662, 1997

A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome. European Heart Journal 32(6): 686-696, 2011

Comparison of a novel, single-lead atrial sensing system with a dual-chamber implantable cardioverter-defibrillator system in patients without antibradycardia pacing indications: results of a randomized study. Circulation. Arrhythmia and Electrophysiology 4(1): 56-63, 2011

Atrial sensing performance of a single-lead VDD pacing system during physical activities. Journal of Electrocardiology 33(3): 253-260, July, 2000

Usefulness of echocardiography to predict inappropriate atrial sensing in single-lead VDD pacing. Pacing and Clinical Electrophysiology 22(9): 1344-1347, 1999

Is atrial sensing of ventricular far-field signals important in single-lead VDD pacing?. Pacing and Clinical Electrophysiology 21(11 Pt 2): 2236-2239, 1998

Pre-implant echocardiography to predict inappropriate atrial sensing in single lead VDD pacing. Journal of the American College of Cardiology 31(2 SUPPL A): 434A, 1998

Single lead DDD system: a comparative evaluation of unipolar, bipolar, and overlapping biphasic stimulation and the effects of right atrial floating electrode location on atrial pacing and sensing thresholds. Pacing and Clinical Electrophysiology 19(11 Pt 2): 1758-1763, 1996

VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system. Pacing and Clinical Electrophysiology 19(4 Pt 1): 455-464, 1996

Selective atrial sensing prevents endless loop tachycardias in single pass lead vdd pacing. Antonioli, G E , A E Aubert And H Ector (Ed ) Clinical Aspects Of Biomedicine, 1 Pacemaker Leads, ; 2nd European Conference on Pacemaker Leads, Ferrara, Italy, April 11-12, Xv+627p Elsevier Science Publishers B V : Amsterdam, Netherlands; (Dist in The Usa And Canada By Elsevier Science Publishing Co , Inc : New York, New York, Usa) Illus 153-160, 1991