Initial clinical experience with a dual chamber rate responsive implantable cardioverter defibrillator



Initial clinical experience with a dual chamber rate responsive implantable cardioverter defibrillator



Pacing and Clinical Electrophysiology 23(11 Pt 2): 1986-1988



The present study reports the first clinical experience with the Photon DR dual chamber rate responsive ICD. Fifty-seven patients (mean age 67.6 +/- 10 years) with a mean LVEF of 0.332 in NYHA Class I (30%), II (51%), or III (19%) met the implant criteria. Tachyarrhythmia diagnoses included VF (21%), VT (49%), or VT/VF (30%). Additional bradycardia pacing diagnoses included AV block (18%), sinus node dysfunction (5%), and sinus bradycardia (11%). All patients were followed on a long-term basis. A device-based direct current fibrillator (DC fibber) successfully induced VF in 96.2% of 243 attempted inductions. Detection times (2.86 +/- 0.47 s) and redetection times (1.29 +/- 0.32 s) compared favorably with historic controls using a morphology detection (MD) clinical data. Defibrillation energy and voltage thresholds were 10.4 +/- 5.5 J (range 3-28) and 421 V +/- 108 (range 230-696), respectively. Ninety-two clinical arrhythmias were recorded. Using a nominal nonindividualized algorithm, the sensitivity for VT detection was 100% and specificity for SVT rejection 81%. There were six patient deaths (2 nonsudden arrhythmic, 2 cardiac, 2 other). In conclusion, early clinical experience with the Photon DR ICD supports its safety, efficacy, and ability to provide advanced dual chamber ICD features.

(PDF 0-2 workdays service: $29.90)

Accession: 046415549

Download citation: RISBibTeXText

PMID: 11139973



Related references

Initial clinical experience with the first dual-chamber implantable cardioverter defibrillator. Circulation 94(8 SUPPL ): I562, 1996

Initial experience with an implantable cardioverter defibrillator providing dual chamber rate adaptive pacing and sensing. Journal of the American College of Cardiology 31(2 SUPPL A): 294A, 1998

Dual-Chamber Implantable Cardioverter Defibrillator vs Single-Chamber Implantable Cardioverter Defibrillator High incidence of device and lead related complications in Dual-Chamber Implantable Cardioverter Defibrillator. Journal of the American College of Cardiology 35(2 suppl A): 127A, 2000

Worldwide clinical experience with a new dual-chamber implantable cardioverter defibrillator. Circulation 98(17 SUPPL ): I191, Oct 27, 1998

Worldwide clinical experience with a new dual-chamber implantable cardioverter defibrillator system. Journal of Cardiovascular Electrophysiology 12(5): 521-528, 2001

Clinical experience with a dual-chamber implantable cardioverter defibrillator to treat atrial tachyarrhythmias. Journal of Cardiovascular Electrophysiology 12(11): 1247-1253, 2002

Clinical experience with a dual-chamber implantable cardioverter defibrillator to treat atrial tachyarrhythmias. Journal of Cardiovascular Electrophysiology 12(11): 1247-1253, November, 2001

Worldwide clinical experience with a dual-chamber implantable cardioverter defibrillator in patients with atrial fibrillation and flutter. European Heart Journal 20(ABSTR SUPPL ): 114, 1999

First worldwide clinical experience with a new dual chamber implantable cardioverter defibrillator. Advantages and complications. The Ventak AV II DR investigators. Europace 1(2): 96-102, 2001

Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry. Journal of the American College of Cardiology 58(10): 1007-1013, 2011

Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators. Europace 3(3): 181-186, 2001

Long-term experience with the first dual-chamber implantable cardioverter-defibrillator. European Heart Journal 18(ABSTR SUPPL ): 95, 1997

Clinical evaluation of a dual chamber implantable cardioverter-defibrillator. Polski Merkuriusz Lekarski 9(50): 522-526, 2000

Clinical investigation of a new dual-chamber implantable cardioverter defibrillator with improved rhythm discrimination capabilities. Journal of Cardiovascular Electrophysiology 14(2): 144-149, February, 2003

Delayed detection of ventricular tachycardia in a dual chamber rate adaptive pacing implantable cardioverter defibrillator: a case of intradevice interaction. Pacing and Clinical Electrophysiology 28(1): 76-77, 2005