Is there any real advantage in the double-lumen cannula?



Is there any real advantage in the double-lumen cannula?



Aesthetic Plastic Surgery 21(1): 38-42



The author demonstrates one of liposuction's great problems, what he calls the "contra-vacuum," which forms inside the cannula while it is inserted under the skin. To keep liposuction effective, an ascending pressure is needed while the holes of the cannula are deep inside the tissues. The results are higher pressure, more tissue trauma, less effectiveness. To prevent these problems, the author developed a double-lumen cannula in 1983; because of a secondary tube outside it, there is no contra-vacuum formation. He presents here his experience in large liposuctions with a new cannula model, thinner than the first one, but also very effective.

(PDF emailed within 0-6 h: $19.90)

Accession: 046480963

Download citation: RISBibTeXText

PMID: 9204166

DOI: 10.1007/s002669900079



Related references

Total respiratory support with single cannula venovenous ECMO: double lumen continuous flow vs. single lumen tidal flow. Transactions - American Society for Artificial Internal Organs 31: 610-615, 1985

Development of a Double-Lumen Cannula for a Percutaneous RVAD. Asaio Journal 61(4): 397-402, 2016

Further experience with a double-lumen subclavian cannula for hemodialysis. Transactions - American Society for Artificial Internal Organs 28: 71-75, 1982

Double lumen percutaneous cannula for dialysis with the artificial kidney. Transactions - American Society for Artificial Internal Organs 10: 136-139, 1964

A double-lumen subclavian cannula (DLSC) for temporary hemodialysis access. Transactions - American Society for Artificial Internal Organs 26: 93-98, 1980

Venovenous extracorporeal membrane oxygenation (ECMO) using a double-lumen cannula. Artificial Organs 11(3): 265-268, 1987

Use of a venous double-lumen cannula for ECMO in a neonate with congenital heart disease. Annals of Thoracic Surgery 66(4): 1467-1468, 1998

The use of double lumen cannula for veno-venous ECMO in trauma patients with ARDS. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine 23(): 30-30, 2016

Numerical and experimental flow analysis of the Wang-Zwische double-lumen cannula. Asaio Journal 57(4): 318-327, 2011

New double-lumen polyethylene cannula for push-pull perfusion of brain tissue in vivo. Journal of Neuroscience Methods 12(3): 205-218, 1985

Wang-Zwische double lumen cannula-toward a percutaneous and ambulatory paracorporeal artificial lung. Asaio Journal 54(6): 606-611, 2008

Patient-Specific Atrial Hemodynamics of a Double Lumen Neonatal Cannula in Correct Caval Position. Artificial Organs, 2018

Uneven double-lumen cannula for rescue guidewire technique in endoscopic ultrasonography-guided hepaticogastrostomy. Endoscopy 49(10): E264-E265, 2017

Patient-Specific Atrial Hemodynamics of a Double Lumen Neonatal Cannula in Correct Caval Position. Artificial Organs 42(4): 401-409, 2018

Implantation of a double lumen bi-caval cannula for veno-venous extracorporeal membrane oxygenation (ECMO). Deutsche Medizinische Wochenschrift 139(15): 792-794, 2014