+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Translate
+ Recently Requested

Maturation of the sensed electrogram amplitude over time in a new subcutaneous implantable loop recorder



Maturation of the sensed electrogram amplitude over time in a new subcutaneous implantable loop recorder



Pacing and Clinical Electrophysiology 20(6): 1686-1690



The cause of recurrent syncope may be difficult to determine if the diagnosis is not established from initial noninvasive and invasive testing. Eighteen patients with recurrent syncope and negative tilt table and electrophysiological testing underwent implantation of a left pectoral subcutaneous loop recorder. This device "freezes" the preceding 7.5 or 15 minute rhythm strip after magnet application after spontaneous syncope. Baseline and follow-up electrograms were routinely recorded, and patients were followed until syncope recurred. Three patients had syncope within 1 month of implantation and were excluded from this report. Implantation electrogram amplitude was 250 +/- 124 microV and increased to 291 +/- 114 microV at 2-3 months, and increased further to 353 +/- 167 microV at 4-6 months (P < 0.001, ANOVA). Syncope recurred in 14 of the 15 patients. An arrhythmic basis for syncope was established (n = 7) or excluded (n = 7) in every patient who had recurrent syncope. All syncopal episodes were associated with diagnostic sensed electrograms. The increase in sensed electrogram amplitude over time suggests a maturation of the device-tissue interface. These results support the long-term viability of this implantable monitoring technique.

(PDF emailed within 0-6 h: $19.90)

Accession: 046631798

Download citation: RISBibTeXText

PMID: 9227768

DOI: 10.1111/j.1540-8159.1997.tb03540.x


Related references

A Retrospective Analysis of Implantable Loop Recorder in Victoria - Time to Diagnosis of Aetiology, and Correlation with R-Wave Amplitude. Heart Lung & Circulation 25: S136-S137, 2016

Positional pseudo-alternating bundle-branch-block on implantable loop recorder electrogram. Indian Pacing and Electrophysiology Journal 18(6): 240-241, 2018

Electrogram amplitude with a new minimally invasive insertable loop recorder Surface mapping and implant electrograms. Circulation 96(8 SUPPL ): I522, 10/21/97, 1997

Value of subcutaneous implantable loop recorder for detection of paroxysmal asystole underlying unexplained syncope. European Heart Journal 23(Abstract Supplement): 360, August-September, 2002

Update on cardiac implantable electronic devices: from the injectable loop recorder to the leadless pacemaker, to the subcutaneous defibrillator. Minerva Cardioangiologica 66(6): 762-769, 2018

Heart rhythm at the time of death documented by an implantable loop recorder. Europace 12(2): 254-260, 2010

The implantable loop recorder: the herald of a new age of implantable monitors. Pacing and Clinical Electrophysiology 23(10 Pt 1): 1456-1456, 2000

Extended ECG monitoring with an implantable loop recorder in patients with cryptogenic stroke: time schedule, reasons for explantation and incidental findings (results from the TRACK-AF trial). Clinical Research in Cardiology, 2018

The implantable loop recorder. Revue Medicale Suisse 3(138): 2914-2918, 2008

The implantable loop recorder in children. Heart 94(7): 888-891, 2007

Use of the implantable loop recorder in children and adolescents. Cardiology in the Young 16(6): 572-578, 2006

Outcome of implantable loop recorder evaluation. Cardiology Journal 25(3): 363-370, 2017

Syncope: Experience with the implantable loop recorder. Acc Current Journal Review 8(1): 80-84, 1999

Implantable loop recorder BioMonitor 2 (Biotronik). Herzschrittmachertherapie & Elektrophysiologie 27(4): 337-340, 2016

Use of an implantable loop recorder: initial experience. Revista Portuguesa de Cardiologia 22(12): 1479-1483, 2004