+ Site Statistics
References:
52,654,530
Abstracts:
29,560,856
PMIDs:
28,072,755
+ Search Articles
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ PDF Full Text
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn

+ Translate
+ Recently Requested

Optimization of square wave anodic stripping voltammetry (SWASV) for the simultaneous determination of Cd, Pb, and Cu in seawater and comparison with differential pulse anodic stripping voltammetry (DPASV)



Optimization of square wave anodic stripping voltammetry (SWASV) for the simultaneous determination of Cd, Pb, and Cu in seawater and comparison with differential pulse anodic stripping voltammetry (DPASV)



Annali di Chimica 92(3): 313-326



Square wave anodic stripping voltammetry (SWASV) was optimized for the simultaneous determination of Cd, Pb and Cu in coastal seawater samples. Background subtraction was adapted to improve peak detection and quantification. Optimum background voltammograms were obtained by applying a 7.5 s equilibration potential at -975 mV (vs. Ag/AgCl, 3M KCl) before starting the background scan. Voltammetric scan parameters were optimized to obtain maximum sensitivity while retaining good peak resolution and discrimination from background. Optimal parameters were: frequency 100 Hz, pulse amplitude 25 mV, current sampling delay time 2 ms, step height 8 mV. The sensitivity of optimized SWASV proved to be more than double that of differential pulse anodic stripping voltammetry (DPASV), and analysis time was halved. Samples containing around 13 (Cd), 30 (Pb), 200 (Cu) ng/l (typical averages of the coastal area of the Marche region) can be analyzed using a 5 min deposition time and the total analysis time using three standard additions is about 1 h and half, excluding the mercury film preparation and the outgassing of the sample, which can be made in parallel using a second cell cup.

(PDF emailed within 1 workday: $29.90)

Accession: 046874368

Download citation: RISBibTeXText

PMID: 12025515



Related references

Determination of arsenic by anodic stripping voltammetry and differential pulse anodic stripping voltammetry. Analytical Chemistry 47(9): 1586-1592, 1975

Square-Wave Anodic Stripping Voltammetry (SWASV) for the Determination of Ecotoxic Metals, Using a Bismuth-Film Electrode. Analytical Letters 44(5): 761-777, 2011

Determination of Cd, Cu, Pb and Zn content of infant formulas by differential pulse anodic stripping voltammetry (DPASV). Nahrung 38(4): 386-392, 1994

The determination of zinc content in wines by differential pulse anodic stripping voltammetry (DPASV). Czech Journal of Food Sciences 17(2): 73-76, 1999

Trace-element determination of platinium by differential pulse anodic stripping voltammetry (DPASV) using the glassy carbon electrode. Fresenius' Zeitschrift fuer Analytische Chemie 320(2): 152-155, 1985

Disposable electrochemical sensor for rapid measurement of heavy metals in fish by square wave anodic stripping voltammetry (SWASV). Veterinary Research Communications 33 Suppl 1: 249-252, 2009

Simultaneous determination of Cd, Pb, Cu and Zn in different materials using differential pulse anodic stripping voltammetry. Pakistan Journal of Scientific and Industrial Research 32(9): 639-642, 1989

The application of thallium iii ions in oxidimetric determinations part 2 indirect determination of cysteine and thioureas by means of differential pulse anodic stripping voltammetry dpasv. Die Pharmazie 46(1): 31-33, 1991

Determination of antibilharzial antimony compounds by direct current, differential pulse, square-wave and alternating current anodic stripping voltammetry. Fresenius' Journal of Analytical Chemistry 358(6): 745-748, 1997

Chelating resin preconcentration and Hg(II) assisted elution followed by differential-pulse anodic stripping voltammetry for the determination of Cd, Cu, and Pb in seawater. Fresenius' Journal of Analytical Chemistry 360(5): 550-555, 1998

Determination of inorganic antimony species in seawater by differential pulse anodic stripping voltammetry: Stability of the trivalent state. Analytica Chimica Acta 452(2): 237-244, 11 February, 2002

Optimization of instrumental parameters for square-wave anodic stripping voltammetry. Talanta 30(7): 459-464, 1983

Simultaneous determination of the toxic trace metals Cd, Cu, Pb and Zn in soils by differential pulse anodic stripping voltammetry. Fresenius Zeitschrift fur Analytische Chemie 313(5): 390-394, 1982

Digestion-free determination of heavy metals (Pb, Cd, Cu) in honey using anodic stripping differential pulse voltammetry and potentiometric stripping analysis. Fresenius' Journal of Analytical Chemistry 351(7): 678-682, 1995

Direct measurement of equilibrium constants for water-soluble porphyrin with copper(II) and cobalt(II) by differential pulse anodic stripping voltammetry (DPASV). Journal of Porphyrins and Phthalocyanines 16(2): 235-0, 2012