EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Pulse oximetry in the air rescue service. 2: Methods of increasing the stability of pulse oximetry measurements--ECG-synchronized pulse oximetry and adhesive sensors



Pulse oximetry in the air rescue service. 2: Methods of increasing the stability of pulse oximetry measurements--ECG-synchronized pulse oximetry and adhesive sensors



Anasthesiologie, Intensivmedizin, Notfallmedizin, Schmerztherapie 28(3): 174-178



Pulse oximetric monitoring in air rescue service (rescue helicopter) is primarily influenced by motion artifacts (especially those of a passive nature), by low perfusion and by the problem of probe dislocation. In a prospective study involving 162 unselected emergency patients treated by the medical team of the emergency helicopter service "Christoph 22" (Ulm), we studied the possibility of reducing these adverse factors by applying available state-of-the-art technology, such as ECG-synchronization and adhesive probes. By applying the thus modified methods of monitoring, the interference factor was reduced to S = 0.056, that is only 5.6% of measurement time was adversely effected. The increase in measurement stability resulted from the reduction in number of described artifacts (motion artifacts and low perfusion), as well as from the reduction in duration of interfered measurement time. ECG-synchronization very effectively influenced the passive motion artifacts. Their frequency was reduced by the factor 8.2, respectively 42. An effective reduction in number of probe dislocations can be achieved by applying adhesive probes. The high costs of such probes presently limits their application. Radiation can be eliminated by redesigning the probe. ECG-synchronization of pulse oximetric signal has proved to be a method to reduce the artifacts frequently experienced in air rescue and has considerably contributed to the increase of emergency patient safety.

(PDF emailed within 0-6 h: $19.90)

Accession: 047132382

Download citation: RISBibTeXText

PMID: 8318602

DOI: 10.1055/s-2007-998901



Related references

Multicenter study on the clinical value of fetal pulse oximetry. II. Compared predictive values of pulse oximetry and fetal blood analysis. The French Study Group on Fetal Pulse Oximetry. American Journal of Obstetrics and Gynecology 177(3): 593-598, 1997

Esophageal pulse oximetry is more accurate and detects hypoxemia earlier than conventional pulse oximetry during general anesthesia. Frontiers of Medicine 6(4): 406-410, 2013

Accuracy of Smartphone-Based Pulse Oximetry Compared with Hospital-Grade Pulse Oximetry in Healthy Children. Telemedicine Journal and E-Health 24(7): 527-535, 2017

Worlds first combined digital pulse oximetry pulse oximetry and carbon dioxide tension ear sensor. Anesthesia & Analgesia 94(1S Supplement): S103, January, 2002

Transesophageal pulse oximetry A comparison with surface pulse oximetry and arterial oxygen saturation in ICU patients. Acta Anaesthesiologica Scandinavica 41(SUPPL 111): 339, 1997

Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement. Journal of Clinical Monitoring 4(3): 223-226, 1988

Comparison of transesophageal pulse oximetry with peripheral surface pulse oximetry in CAGB patients. Anesthesiology (Hagerstown) 85(3A): A485, 1996

False reassurance of pulse oximetry: Pulse oximetry a poor guide to limb perfusion. Bmj 307(6906): 733-733, 1993

Noninvasive patient observation in veterinary medicine: pulse oximetry and capnography. I. Pulse oximetry. Tierarztliche Praxis 22(6): 596-606, 1994

Intra arterial catheter oximetry and pulse oximetry compared to carbon monoxide oximetry in cardiac anesthesia. Der Anaesthesist 40(11): 602-607, 1991

Intra-arterial catheter oximetry and pulse oximetry in comparison with CO-oximetry in heart surgery. Der Anaesthesist 40(11): 602-607, 1991

The successful use of transesophageal pulse oximetry in a patient in whom peripheral pulse oximetry was unobtainable. Anesthesia and Analgesia 85(3): 514-516, 1997

Pocket Pulse Oximetry Versus Standard Pulse Oximetry: Accuracy and Precision. Chest Journal 145(3): 549a-1-549a-2, 2014

Continuous intra-arterial oximetry, pulse oximetry, and co-oximetry during cardiac surgery. Journal of Cardiothoracic and Vascular Anesthesia 6(6): 668-673, 1992

Esophageal pulse oximetry is more reliable than surface pulse oximetry in ICU-patients. Anesthesiology (Hagerstown) 87(3 SUPPL ): A389, 1997