Radiation dose and image quality in diagnostic radiology. Optimization of the dose-image quality relationship with clinical experience from scoliosis radiography, coronary intervention and a flat-panel digital detector



Radiation dose and image quality in diagnostic radiology. Optimization of the dose-image quality relationship with clinical experience from scoliosis radiography, coronary intervention and a flat-panel digital detector



Acta Radiologica. Supplementum 43(427): 1-43



X-rays are known to cause malignancies, skin damage and other side effects and they are thus potentially dangerous. Therefore, it is essential and in fact mandatory to reduce the radiation dose in diagnostic radiology as far as possible. This is also known as the ALARA (as low as reasonably achievable) principle. However, the dose is linked to image quality and the image quality may not be lowered so far that it jeopardizes the diagnostic outcome of a radiographic procedure. The process of reaching this balance between dose and image quality is called optimization. The aim of this thesis was to propose and evaluate methods for optimizing the radiation dose-image quality relationship in diagnostic radiography with a focus on clinical usefulness. The work was performed in three main parts. OPTIMIZATION OF SCOLIOSIS RADIOGRAPHY: In the first part, two recently developed methods for digital scoliosis radiography (digital exposure and pulse fluoroscopy) were evaluated and compared to the standard screen-film method. Radiation dose was measured as kerma area-product (KAP), entrance surface dose (ESD) and effective dose; image quality was assessed with a contrast-detail phantom and through visual grading analysis. Accuracy in angle measurements was also evaluated. The radiation dose for digital exposure was nearly twice as high as the screen-film method at a comparable image quality while the dose for pulsed fluoroscopy was very low but with a considerably lower image quality. The variability in angle measurements was sufficiently low for all methods. Then, the digital exposure protocol was optimized to a considerably lower dose with a slightly lower image quality compared to the baseline. FLAT-PANEL DETECTOR: In the second part, an amorphous-silicon direct digital flat-panel detector was evaluated using a contrast-detail phantom, measuring dose as entrance dose. The flat-panel detector yielded a superior image quality at a lower dose than both storage phosphor plates and screen-film. Equivalent image quality compared to storage phosphor plates was reached at about one-third of the dose. OPTIMIZATION OF PERCUTANEOUS CORONARY INTERVENTION (PCI): In the third part, influence of various settings on radiation dose and image quality in coronary catheterisation and PCI was investigated. Based on these findings, the dose rate for fluoroscopy was reduced to one-third. The dose reduction was evaluated in a clinical series of 154 PCI procedures before and 138 after the optimization. Through this optimization, the total KAP was significantly reduced to two-thirds of the original value. This thesis indicates the possibility of dose reduction in diagnostic radiology through optimization of the radiographic process.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 047159346

Download citation: RISBibTeXText

PMID: 12108231


Related references

Radiation dose reduction in scoliosis patients: low-dose full-spine radiography with digital flat panel detector and image stitching system. Rofo 183(7): 645-649, 2011

Radiography of scoliosis: Comparative dose levels and image quality between a dynamic flat-panel detector and a slot-scanning device (EOS system). Diagnostic and Interventional Imaging 96(11): 1177-1188, 2015

Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography. Ajr. American Journal of Roentgenology 171(1): 23-27, 1998

Routine chest radiography using a flat-panel detector: image quality at standard detector dose and 33% dose reduction. Ajr. American Journal of Roentgenology 178(1): 169-171, 2002

Routine skeleton radiography using a flat-panel detector: image quality and clinical acceptance at 50% dose reduction. Investigative Radiology 38(4): 230-235, 2003

Radiation dose reduction without compromise of image quality in cardiac angiography and intervention with the use of a flat panel detector without an antiscatter grid. Heart 92(4): 507-510, 2005

Chest radiography with a flat-panel detector: image quality with dose reduction after copper filtration. Radiology 237(2): 691-700, 2005

Comparison of image quality and radiation dose between an image-intensifier system and a newer-generation flat-panel detector system — technical phantom measurements and evaluation of clinical imaging in children. Pediatric Radiology 46(2): 286-292, 2016

Flat panel digital radiography compared with storage phosphor computed radiography: assessment of dose versus image quality in phantom studies. Investigative Radiology 37(11): 609-614, 2002

Image quality vs. radiation dose for a flat-panel amorphous silicon detector: a phantom study. European Radiology 11(9): 1704-1709, 2001

Super-resolution variable-dose imaging in digital radiography: quality and dose reduction with a fluoroscopic flat-panel detector. International Journal of Computer Assisted Radiology and Surgery 6(5): 663-673, 2011

Dynamic flat panel detector versus image intensifier in cardiac imaging: dose and image quality. Physics in Medicine and Biology 50(23): 5731-5742, 2005

Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier. Physics in Medicine and Biology 52(1): 183-196, 2007

Digital subtraction angiography during transjugular intrahepatic portosystemic shunt creation or revision: data on radiation exposure and image quality obtained using a standard and a low-dose acquisition protocol in a flat-panel detector-based system. Abdominal Imaging 40(6): 1808-1812, 2015

Image quality assessment tools for radiation dose optimization in digital radiography: an overview. Radiologic Technology 85(5): 555-562, 2015