+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Simultaneous determination of Cd, Pb, Cu, Sb, Bi, Se, Zn, Mn, Ni, Co and Fe in water samples by differential pulse stripping voltammetry at a hanging mercury drop electrode



Simultaneous determination of Cd, Pb, Cu, Sb, Bi, Se, Zn, Mn, Ni, Co and Fe in water samples by differential pulse stripping voltammetry at a hanging mercury drop electrode



Fresenius' Journal of Analytical Chemistry 367(4): 378-383



A highly sensitive and selective voltammetric procedure is described for the simultaneous determination of eleven elements (Cd, Pb, Cu, Sb, Bi, Se, Zn, Mn, Ni, Co and Fe) in water samples. Firstly, differential pulse anodic stripping voltammetry (DPASV) with a hanging mercury drop electrode (HMDE) is used for the direct simultaneous determination of Cd, Pb, Cu, Sb and Bi in 0.1 M HCI solution (pH = 1) containing 2 M NaCl. Then, differential pulse cathodic stripping voltammetry (DPCSV) is used for the determination of Se in the same solution. Zn is subsequently determined by DPASV after raising the pH of the same solution to pH 4. Next, the pH of the medium is raised to pH 8.5 by adding NH3/NH4Cl buffer solution for the determination of Mn by DPASV. Ni and Co are determined in the same solution by differential pulse adsorptive stripping voltammetry (DPAdSV) after adding DMG (1 x 10(-4) M). Finally, 1 x 10(-5) M 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) is added to the solution for the determination of Fe by DPAdSV. The optimal conditions are described. Relative standard deviations and relative errors are calculated for the eleven elements at three different concentration levels. The lower detection limits for the investigated elements range from 1.11 x 10(-10) to 1.05 x 10(-9)M, depending on the element determined. The proposed analysis scheme was applied for the determination of these eleven elements in some ground water samples.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 047373462

Download citation: RISBibTeXText

PMID: 11225865


Related references

Direct and simultaneous determinations of Zn, Cd, Pb, Cu, Sb and Bi dissolved in sea water by differential pulse anodic stripping voltammetry with a hanging mercury drop electrode. Analytica Chimica Acta 106(1): 23-37, 1979

Determination of trace amounts of bacitracin by differential pulse adsorptive stripping voltammetry at a hanging mercury drop electrode. Analytical Proceedings 28(1): 16-20, 1991

Determination of naringin in grapefruit juice by cathodic stripping differential pulse voltammetry at the hanging mercury drop electrode. Analytica Chimica Acta. 360(1-3): 179-187, Ch 10, 1998

Trace zinc determination in acid media by differential pulse anodic stripping voltammetry at a hanging drop mercury electrode. Analytical Chemistry 48(4): 759-761, 1976

Determination of Zn, Cd, Pb, Cu, Sb and Bi in milk by differential pulse anodic stripping voltammetry with a hanging mercury drop electrode following two independent mineralisation methods. Analusis 13(10): 471-473, 1985

Studies of pretreatments in the determination of Zn, Cd, Pb, Cu, Sb and Bi in suspended particulate matter and plankton by differential-pulse anodic-stripping voltammetry with a hanging mercury drop electrode. Talanta 29(8): 651-654, 1982

Differential pulse cathodic stripping voltammetry of the copper complexes of glycyl-L-histidyl-glycine at a hanging mercury drop electrode. Talanta 40(10): 1481-1488, 1993

Implementation of a differential pulse anodic stripping voltammetry (DPASV) at a hanging mercury drop electrode (HMDE) procedure for the analysis of airborne heavy metals. Analytical Letters 34(13): 2349-2360, 2001

Differential pulse adsorption stripping voltammetric determination of copper(II) with 2-mercaptobenzimidazol at a hanging mercury-drop electrode. Analytical Sciences 17(5): 609-612, 2001

A rapid determination of trace amounts of bismuth in urine and blood using differential pulse anodic stripping voltammetry at the hanging mercury electrode. Analytical Letters 14(B15): 1209-1220, 1981

Direct determination of trace and sub trace metals in natural waters by differential pulse anodic stripping voltammetry use of long lasting sessile drop mercury electrodes compared to commercial hanging drop mercury electrodes kemula type. Analytical Letters 15(19): 1565-1584, 1982

Determination of arsenic by cathodic stripping voltammetry at a hanging mercury drop electrode. Microchimica Acta 111(1-3): 55-62, 1993

Application of polymer-modified hanging mercury drop electrode in the indirect determination of certain beta-lactam antibiotics by differential pulse, ion-exchange voltammetry. Electroanalysis 15(14): 1212-1218, 2003

Determination of Amitraz Pesticide by Adsorptive Stripping Voltammetry on the Hanging Mercury Drop Electrode. Microchimica Acta 137(3-4): 215-220, 2001

Low-level determination of silicon in steels by anodic stripping voltammetry on a hanging mercury drop electrode. Talanta 82(5): 1839-1844, 2010