Spinal cord compression caused by the rod of a Harrington instrumentation device: a late complication in scoliosis surgery



Spinal cord compression caused by the rod of a Harrington instrumentation device: a late complication in scoliosis surgery



European Spine Journal 6(3): 208-210



We report a unique complication caused by the rod of a Harrington instrumentation device, which resulted in spinal stenosis and myelopathy. A literature review revealed no previous causes of direct spinal cord impingement caused by the rod of a Harrington device. In this case, years after the initial operation, the rod penetrated the lamina at the junction between a thoracic and a lumbar curve, causing spinal stenosis and myelopathy. We conclude that regular control of the position of the device and awareness of possible late neurological complications are necessary to identify such complications as early as possible.

(PDF emailed within 0-6 h: $19.90)

Accession: 047416450

Download citation: RISBibTeXText

PMID: 9258642

DOI: 10.1007/bf01301439


Related references

Lumbar nerve root compression at the site of hook insertion. Late complication of Harrington rod instrumentation for scoliosis. Spine 10(9): 853-855, 1985

Spinal cord monitoring during harrington instrumentation for scoliosis. Orthopaedic Transactions 5(3): 469, 1981

Cauda equina compression due to a laminar hook: A late complication of posterior instrumentation in scoliosis surgery. European Spine Journal 8(5): 417-420, 1999

Effect of the Harrington compression system on the correction of the rib hump in spinal instrumentation for idiopathic scoliosis. Spine 6(5): 489-493, 1981

Spinal cord monitoring. State of the art. Results in Harrington and C.D. instrumentation for scoliosis. Acta Orthopaedica Belgica 58 Suppl 1: 99-105, 1992

Intraoperative evoked potential monitoring of the spinal cord. A restricted filter, scalp method during Harrington instrumentation for scoliosis. Clinical Orthopaedics and Related Research 1984(183): 42-50, 1984

Understanding your scoliosis surgery: a preoperative teaching booklet for Harrington instrumentation and spinal fusion patients. Ona Journal 5(10): 24-27, 1978

Laboratory testing of segmental spinal instrumentation versus traditional Harrington instrumentation for scoliosis treatment. Spine 7(3): 265-269, 1982

Comparative mechanics of segmental spinal instrumentation vs. traditional harrington instrumentation in scoliosis treatment laboratory analysis. Orthopaedic Transactions 5(1): 16, 1981

Segmental spinal instrumentation (Harrington-Luque) in scoliosis. Zhonghua Wai Ke Za Zhi 24(12): 737-9, 781, 1986

Not all rods are Harrington - an overview of spinal instrumentation in scoliosis treatment. Pediatric Radiology 30(2): 110-118, 2000

Early ambulation following spinal fusion and Harrington instrumentation in idiopathic scoliosis. Clinical Orthopaedics and Related Research 1975(110): 54-62, 1975

Scoliosis treatment by spinal fusion, Harrington instrumentation, and Milwaukee brace. Alabama Journal of Medical Sciences 16(4): 370-373, 1979

Low back pain after spinal fusion and Harrington instrumentation for idiopathic scoliosis. International Orthopaedics 29(1): 47-50, 2004

Treatment of scoliosis in cerebral palsy with spinal fusion and harrington instrumentation. Developmental Medicine & Child Neurology 11(2): 252, 1969