Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support



Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support



Respiratory Care 48(1): 38-45



Automatic tube compensation (ATC), a new ventilation mode that compensates for the work of breathing imposed by endotracheal tube resistance, recently became commercially available. We conducted a laboratory study with a lung model and a Nellcor Puritan Bennett 840 ventilator to compare ATC and pressure-support ventilation (PSV). A bellows-in-a-box lung model simulated spontaneous breathing with the following settings: respiratory rate 10 breaths/min, inspiratory time 1.0 s, peak inspiratory flow 60 L/min without connecting to the ventilator and endotracheal tube (ETT). At each ETT size (5, 6, 7, 8 and 9 mm inner diameter) 100% ATC was compared with pressure support (PS) of 0, 2, 4, 6, 8, and 10 cm H(2)O at positive end-expiratory pressure (PEEP) of 0 and 5 cm H(2)O. The negative deflection (PI) of the "alveolar" pressure (ie, pressure inside the bellows, P(alv)) and the delay time were measured. The PI and total pressure-time product (PTP(tot)) integrated from P(alv) were analyzed. PTP(tot) was subdivided into PTP(trig) (the PTP from the beginning of inspiration to the minimum P(alv)) and PTP(supp) (the PTP from the minimum P(alv) to the return to baseline P(alv)). At PEEP of 0 cm H(2)O: with ETTs of 5, 6, and 7 mm the PI values with ATC corresponded to PS of 0-4 cm H(2)O; with the 8-mm ETT the PI values corresponded to PS of 0 cm H(2)O; with the 9-mm ETT the PI values corresponded to PS of 0-2 cm H(2)O. At PEEP of 5 cm H(2)O, with all ETT sizes the PI values corresponded to PS of 0 cm H(2)O. PTP(tot) and PTP(supp) of ATC corresponded to: PS of 2-4 cm H(2)O with the 5-mm ETT; PS of 2 cm H(2)O with the 6-mm ETT; PS of 0-2 cm H(2)O with the 7-mm ETT; and PS of 0 cm H(2)O with the 8- and 9-mm ETTs, at PEEP of 0 cm H(2)O. PEEP of 5 cm H(2)O was not tested for PTP. PTP(trig) with ATC showed comparable or greater values with each size of ETT. ATC with a Nellcor Puritan Bennett 840 ventilator provided inspiratory ventilatory support corresponding to PS of

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 047422596

Download citation: RISBibTeXText

PMID: 12556260


Related references

Additional work of breathing and breathing patterns in spontaneously breathing patients during pressure support ventilation, automatic tube compensation and amplified spontaneous pattern breathing. European Journal of Anaesthesiology 22(4): 312-314, 2005

Breathing pattern and additional work of breathing in spontaneously breathing patients with different ventilatory demands during inspiratory pressure support and automatic tube compensation. Intensive Care Medicine 23(5): 545-552, 1997

Automatic tube compensation and proportional assist ventilation Clinical experience with these new modes of pressure support in intubated spontaneously breathing patients. Intensivmedizin und Notfallmedizin 33(4): 282-292, 1996

Added work of breathing, ventilatory pattern and recognizability of readiness for extubation during inspiratory pressure support and automatic tube compensation. Unfallchirurg 99(10): 765-770, 1996

Added work of breathing, respiratory pattern and determination of ventilator weaning readiness in inspiratory pressure support and and automatic tube compensation. Der Unfallchirurg 99(10): 764-770, 1996

Extubation after breathing trials with automatic tube compensation, T-tube, or pressure support ventilation. Acta Anaesthesiologica Scandinavica 46(8): 973-979, 2002

During pressure support ventilation automatic compensation for endotracheal tube resistance reduces patient work of breathing and improves patient-ventilator sychrony. Intensive Care Medicine 22(1 Suppl.): S122-0, 1996

Proportional pressure support and automatic tube compensation: new options for assisted spontaneous breathing. Acta Anaesthesiologica Scandinavica. Supplementum 111: 155-159, 1997

Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning patients. European Journal of Anaesthesiology 20(1): 10-16, 2005

Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning patients. European Journal of Anaesthesiology 20(1): 10-16, 2003

Breathing pattern associated with respiratory comfort during automatic tube compensation and pressure support ventilation in normal subjects. Acta Anaesthesiologica Scandinavica 44(3): 223-230, 2000

The extra work of breathing due to the endotracheal tube is abolished during inspiratory pressure support breathing. American Review of Respiratory Disease 137(4 Part 2): 64, 1988

Comparison between automatic tube compensation and continuous positive airway pressure during spontaneous breathing trials. Respiratory Care 55(5): 549-554, 2010

Automatic compensation of endotracheal tube resistance in spontaneously breathing patients. Technology and Health Care 1(4): 281-291, 1994

Comparison of the efficacy of intermittent positive pressure breathing ippb and inspiratory pressure support ips delivered via a mouth piece on the work of breathing wob. American Review of Respiratory Disease 139(4 Part 2): A361, 1989