Three-year follow-up of five posterior composites: in vivo wear



Three-year follow-up of five posterior composites: in vivo wear



Journal of Dentistry 21(2): 74-78



The wear of five posterior composites at occlusal contact areas (OCA) and contact free occlusal areas (CFOA) was evaluated in Class II cavities over a 3-year period with an accurate 3D-measuring technique. A clinical evaluation was also performed. The ultrafine compact-filled composites (Willems et al., 1992) showed acceptable OCA-wear rates ranging from 110 to 149 microns after 3 years. This is very similar to the OCA-wear rate of human enamel on molars, which is about 122 microns after 3 years. The fine compact-filled composite had an unacceptable OCA-wear value of 242 microns after 3 years. The ultrafine midway-filled composite showed an exceptionally high CFOA-wear value of 151 microns after 3 years, which gave the impression of it being gradually washed out of the cavity. Clinically, 70% of the restorations made with the ultrafine midway-filled composite showed excellent colour match after 3 years. For most of the compact-filled composites slightly opaque fillings were noted and 63% of the restorations made with one of these materials were clearly opaque. It can be concluded that the investigated ultrafine compact-filled composites can be considered as amalgam alternatives as far as their wear resistance is concerned.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 047782657

Download citation: RISBibTeXText

PMID: 8473595

DOI: 10.1016/0300-5712(93)90149-K


Related references

Three-year follow-up of five posterior composites: SEM study of differential wear. Journal of Dentistry 21(2): 79-86, 1993

Three year quantitative in vivo wear results of four posterior composites. Journal of Dental Research 66(SPEC ISSUE MAR): 166, 1987

In vivo wear test for posterior composites. 1. Development of wear test predicting composite wear in vivo. Shika Zairyo, Kikai 9(2): 289-294, 1990

In vivo wear of posterior composites and its counterplan before or after insertion. Kokubyo Gakkai Zasshi. Journal of the Stomatological Society, Japan 52(2): 195-209, 1985

In vivo and in vitro wear of potential posterior composites. Journal of Dental Research 63(6): 914-920, 1984

Quantitative in vivo wear of human enamel as acceptance standard for posterior composites. Journal of Dental Research 66(SPEC ISSUE MAR): 182, 1987

In vivo evaluation of four posterior composites: quantitative wear measurements and clinical behavior. Dental Materials 2(3): 106-113, 1986

Clinical evaluation of two packable posterior composites: a five-year follow-up. Journal of the American Dental Association 140(4): 447-454, 2009

Clinical evaluation of two packable posterior composites: 2-year follow-up. Clinical Oral Investigations 10(3): 197-203, 2006

Clinical performance and wear resistance of two compomers in posterior occlusal restorations of permanent teeth: six-year follow-up. Operative Dentistry 32(2): 118-123, 2007

Wear of posterior composites. Attualita Dentale 3(42-43): 60-65, 1987

Marginal quality and wear of extended posterior resin composite restorations: Eight-year results in vivo. Journal of the Mechanical Behavior of Biomedical Materials 50(): 13-22, 2016

The clinical wear of three posterior composites. British Dental Journal 169(11): 355-360, 1990

Clinical wear of posterior composites. Hellenika Stomatologika Chronika. Hellenic Stomatological Annals 33(3): 171-183, 1989

Non-linear in vitro wear of posterior composites with time. Dental Materials 7(4): 258-262, 1991