EurekaMag.com logo
+ Site Statistics
References:
53,869,633
Abstracts:
29,686,251
+ Search Articles
+ Subscribe to Site Feeds
EurekaMag Most Shared ContentMost Shared
EurekaMag PDF Full Text ContentPDF Full Text
+ PDF Full Text
Request PDF Full TextRequest PDF Full Text
+ Follow Us
Follow on FacebookFollow on Facebook
Follow on TwitterFollow on Twitter
Follow on LinkedInFollow on LinkedIn

+ Translate

Two-channel direct-detection Doppler lidar employing a charge-coupled device as a detector



Two-channel direct-detection Doppler lidar employing a charge-coupled device as a detector



Applied Optics 41(6): 1145-1155



A direct-detection Doppler lidar system is demonstrated that uses a CCD as a detector for the first time to our knowledge. The ability to use this linear device with the circular output from a Fabry-Perot etalon comes from use of a circle-to-line converter [Appl. Opt. 29, 1482 (1990)]. In addition to the gains in quantum efficiency obtained through use of this detector, the lidar system described in this paper also has the capability to measure winds from aerosol and molecular backscatter simultaneously in two separate channels by directing the light reflected from one channel into the other. Early measurements with this system are presented; it is shown that, although accurate aerosol wind measurements are easily obtained, molecular measurements require a carefully calibrated inverse model and special hardware to derive accurate wind measurements with this channel.

(PDF emailed within 0-6 h: $19.90)

Accession: 047857516

Download citation: RISBibTeXText

PMID: 11900138

DOI: 10.1364/AO.41.001145



Related references

A fast, direct x-ray detection charge-coupled device. Review of Scientific Instruments 80(8): 083302-083302, 2009

Direct detection of nucleic acid hybridization on the surface of a charge coupled device. Nucleic Acids Research 22(11): 2121-2125, 1994

Direct detection of isotopically labeled metabolites bound to a protein microarray using a charge-coupled device. Journal of Biochemical & Biophysical Methods 51(1): 57-67, 4 March, 2002

Boundary layer scattering measurements with a charge-coupled device camera lidar. Applied Optics 42(15): 2647-2652, 2003

Optimised simultaneous multi-element analysis of environmental slurry samples by inductively coupled plasma atomic emission spectrometry using a segmented array charge-coupled device detector. Analytica Chimica Acta 311(2): 123-134, 1995

Characterization of a charge-coupled-device detector in the 1100-0.14-nm (1-eV to 9-keV) spectral region. Applied Optics 38(1): 29-36, 2008

Measurements of aerosol phase function and vertical backscattering coefficient using a charge-coupled device side-scatter lidar. Optics Express 22(1): 1127-1134, 2014

Direct detection of antimony in environmental and biological samples at trace concentrations by laser-induced fluorescence in graphite furnace with an intensified charge coupled device. Journal of Analytical Atomic Spectrometry 10(8): 539-549, 1995

Design of imaging keratometer with annular object and charge-coupled device detector. Applied Optics 52(35): 8532-8539, 2015

High-sensitivity chromatographic detector incorporating three-dimensional charge coupled device fluorimetry. Journal of Chromatography A 867(1-2): 93-104, Jan 21, 2000

Methodology toward 3D micro X-ray fluorescence imaging using an energy dispersive charge-coupled device detector. Analytical Chemistry 86(23): 11826-11832, 2014

Megapixel charge coupled device ccd detector for tandem scanning confocal microscopy of the living eye. Scanning 12(5): I51-I52, 1990

Two approximations for the geometric model of signal amplification in an electron-multiplying charge-coupled device detector. Proceedings of Spie--the International Society for Optical Engineering 8589: 858905-858905, 2013

Calibration and application of an X-ray image intensifier/ charge-coupled device detector for monochromatic macromolecular crystallography. Journal of Synchrotron Radiation 4(Pt 2): 67-77, 1997

Sample illumination configurations for spatially resolved Raman spectrometry using a charge-coupled device detector. Talanta 42(10): 1379-1383, 1995