Validation of in vivo MR measurement of oxygen saturation after resuscitation with a hemoglobin-based oxygen carrier in a rabbit model



Validation of in vivo MR measurement of oxygen saturation after resuscitation with a hemoglobin-based oxygen carrier in a rabbit model



Academic Radiology 8(7): 583-590



The authors tested whether noninvasive magnetic resonance (MR) oximetry is accurate in the in vivo measurement of oxygen saturation in a stroma-free, hemoglobin-based oxygen carrier (HBOC). A central venous catheter was placed in the inferior vena cava (IVC) of 10 New Zealand white rabbits (weight range, 2.5-3.2 kg). Each rabbit underwent removal of 20% of blood volume followed by resuscitation with 10 mL/kg of bovine HBOC-200. Oxygen saturation of the blood mixture was measured in vivo at the IVC with MR oximetry, with separate in vitro calibration for each animal. Blood drawn from the IVC was measured with ex vivo oximetry, which was used as the standard of reference. The in vivo and ex vivo measurements were compared. There was no significant difference (P > .1) between measurements obtained with MR oximetry and ex vivo oximetry. The results with in vivo MR oximetry demonstrated excellent correlation with those from ex vivo oximetry (r = 0.99) over a wide range of physiologic oxygen saturation values (16.7%-74.9%) in venous blood. Noninvasive in vivo MR measurement of oxygen saturation is valid for whole blood mixed with stroma-free hemoglobin. Therefore, MR oximetry may be clinically useful for assessing the oxygenation status in patients resuscitated with a HBOC.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 047914805

Download citation: RISBibTeXText

PMID: 11450958

DOI: 10.1016/s1076-6332(03)80682-7


Related references

Room G, 10/16/2000 2: 00 PM - 4: 00 PM (PS) Validation of MR In-Vivo Measurement of Oxygen Saturation after Resuscitation with a Hemoglobin-Based Oxygen Carrier in a Rabbit Model. Anesthesiology 93(Suppl.): A-417, 2000

Validation of MR In-Vivo Measurement of Oxygen Saturation after Resusciation with a Hemoglobin-Based Oxygen Carrier in a Rabbit Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2000): Abstract No 417, 2002

Validation of oxygen saturation measurements in a canine model of hemoglobin-based oxygen carrier infusion. American Journal of Therapeutics 10(1): 21-28, 2003

Validation of oxygen saturation measurements in a canine model of hemoglobin based oxygen carrier (HBOC) infusion. Clinical Laboratory Science 13(2): 173-179, 2000

Validity of arterial and mixed venous oxygen saturation measurements in a canine hemorrhage model after resuscitation with varying concentrations of hemoglobin-based oxygen carrier. Anesthesia and Analgesia 96(1): 46-50 Table of Contents, 2003

Validity of arterial and mixed venous oxygen saturation measurements in a canine hemorrhage model after resuscitation with varying concentrations of hemoglobin-based oxygen carrier. Anesthesia & Analgesia 96(1): 46-50, 2003

Comparing Arterial Oxygen Saturation from a Nellcor Oxygen Saturation Monitor, IL Co-Oximeter and with Varying Concentrations of Hemoglobin-Based Oxygen Carrier in a Dog Hemorrhage Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2001): Abstract No A-557, 2002

Mixed Venous Oxygen Saturation Measured with an Abbot Oximetric Pulmonary Artery Catheter, and Instrumentation Laboratory Co-Oximeter after Resuscitation with Varying Concentrations of Hemoglobin-Based Oxygen Carrier in a Dog Hemorrhage Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2001): Abstract No A-556, 2002

Augmented Oxygen Offloading by the Hemoglobin-Based Oxygen Carrier Hemoglobin Glutamer-200 Following Resuscitation in a Canine Hypovolemia Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting ( ): Abstract No A-679, 2002

Intraoperative in-vivo measurement of hemoglobin, oxy-hemoglobin, oxygen-saturation and cytochrome aa3 with the NIOS multiscan OS 10/30TM A new method for determination of cerebral blood flow and oxygen metabolism in brain tumors and vascular malformations. Marmarou, A , Bullock, R , Avezaat, C , Baethmann, A , Becker, D , Brock, M , Hoff, J , Nagai, H , Reulen, H -J Acta Neurochirurgica Supplement; Intracranial pressure and neuromonitoring in brain injury : 396, 1998

Effects of a novel hemoglobin-based oxygen carrier on percent oxygen saturation as determined with arterial blood gas analysis and pulse oximetry. Annals Of Emergency Medicine. 27(2): 164-169, 1996

Resuscitation with a novel hemoglobin-based oxygen carrier in a Swine model of uncontrolled perioperative hemorrhage. Journal of Trauma 54(5): 915-924, 2003

Implications of altered hemoglobin concentration with variations in oxygen consumption, arterial oxygen saturation, and age based on a mathematical model for the utilization of reserve oxygen transport capacity. Advances in Experimental Medicine and Biology 180: 523-529, 1984

Oxygen transport by erythrocyte/hemoglobin solution mixtures in an in vitro capillary as a model of hemoglobin-based oxygen carrier performance. Microvascular Research 55(1): 54-64, 1998

Resuscitation following severe, controlled hemorrhage associated with a 24 h delay to surgical intervention in swine using a hemoglobin based oxygen carrier as an oxygen bridge to definitive care. Resuscitation 74(2): 332-343, 2007