Validation of oxygen saturation measurements in a canine model of hemoglobin-based oxygen carrier infusion



Validation of oxygen saturation measurements in a canine model of hemoglobin-based oxygen carrier infusion



American Journal of Therapeutics 10(1): 21-28



This study was designed to validate oxygen saturation measurements from the NOVA CO-Oximeter (NOVA Biomedical Corporation, Waltham, MA), the i-STAT System (Sensor Devices, Waukesha, WI), and the Corning 170 blood gas analyzer (Bayer Corporation, East Walpole, MA) under conditions similar to the clinical application of a hemoglobin-based oxygen carrier (HBOC, hemoglobin glutamer-200 [bovine]; Oxyglobin, Biopure Corporation, Cambridge, MA). A canine model was used for both in vitro and in vivo experiments. In vivo experiments were conducted in a canine laboratory, and in vitro experiments were conducted in a tonometry laboratory. Study subjects were six mixed-breed dogs, each weighing approximately 30 kg. In the first set of experiments, the target blood po(2) levels were reached by tonometry. In the second set of experiments, quantitative measurements of total oxygen content with the LEXO2CON-K (HOSPEX Fiberoptics, Chestnut Hill, MA) were performed, immediately followed by measurements with the NOVA CO-Oximeter and the i-STAT system. HBOC was added in concentrations of 16.2, 32.5, 65, and 97.5 g/L. To analyze the clinical significance of the differences in the results obtained with the each investigated instrument, blood samples from dogs treated with HBOC after acute hemorrhagic shock were used. Oxygen saturation, oxygen content, and po(2) were measured. There was a strong correlation between the oxygen saturation values measured with the investigated instruments in samples after tonometry and known po(2). The total calculated oxygen content varied by 5% based on results generated by calculations using the investigated instruments. The results did not change with different oxygenation of the sample. The differences among methods were not significant when the HBOC concentration was 16.2 g/L. Higher concentrations of HBOC increased the difference between calculated and measured oxygen content; the i-STAT system demonstrated a greater deviation compared with the results of the other two instruments. Systemic oxygen uptake using the investigated instruments showed a high correlation with values based on LEXO2CON-K measurements (R = 0.97 for CO-Oximeter, R = 0.96 for Corning 170 blood gas analyzer, and R = 0.79 for i-STAT system). Systemic oxygen uptake values based on CO-Oximeter and Corning 170 blood gas analyzer data showed 75% accuracy; i-STAT system accuracy was 63% for control samples and 50% for samples after HBOC infusion.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 047914880

Download citation: RISBibTeXText

PMID: 12522516

DOI: 10.1097/00045391-200301000-00006


Related references

Validation of oxygen saturation measurements in a canine model of hemoglobin based oxygen carrier (HBOC) infusion. Clinical Laboratory Science 13(2): 173-179, 2000

Validity of arterial and mixed venous oxygen saturation measurements in a canine hemorrhage model after resuscitation with varying concentrations of hemoglobin-based oxygen carrier. Anesthesia and Analgesia 96(1): 46, 2003

Validity of arterial and mixed venous oxygen saturation measurements in a canine hemorrhage model after resuscitation with varying concentrations of hemoglobin-based oxygen carrier. Anesthesia and Analgesia 96(1): 46-50, 2003

Validation of in vivo MR measurement of oxygen saturation after resuscitation with a hemoglobin-based oxygen carrier in a rabbit model. Academic Radiology 8(7): 583-590, 2001

Validation of MR In-Vivo Measurement of Oxygen Saturation after Resusciation with a Hemoglobin-Based Oxygen Carrier in a Rabbit Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2000): Abstract No 417, 2002

Room G, 10/16/2000 2: 00 PM - 4: 00 PM (PS) Validation of MR In-Vivo Measurement of Oxygen Saturation after Resuscitation with a Hemoglobin-Based Oxygen Carrier in a Rabbit Model. Anesthesiology 93(Suppl.): A-417, 2000

Comparing Arterial Oxygen Saturation from a Nellcor Oxygen Saturation Monitor, IL Co-Oximeter and with Varying Concentrations of Hemoglobin-Based Oxygen Carrier in a Dog Hemorrhage Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2001): Abstract No. A-557, 2002

Oxygen Saturation Measurements in Canine Blood after Hemoglobin glutamer-200 infusion In-Vitro Validation of the Nova CO-Oximeter. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2000): Abstract No 407, 2002

Room 302, 10/18/2000 2: 00 PM - 3: 30 PM (PD) Oxygen Saturation Measurements in Canine Blood after Hemoglobin glutamer-200 (bovine) (HBOC) infusion: In-Vitro Validation of the Nova CO-Oximeter. Anesthesiology 93(Suppl.): A-407, 2000

Augmented Oxygen Offloading by the Hemoglobin-Based Oxygen Carrier Hemoglobin Glutamer-200 Following Resuscitation in a Canine Hypovolemia Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting: Abstract No. A-679, 2002

Arterial oxygenation and oxygen delivery after hemoglobin-based oxygen carrier infusion in canine hypovolemic shock: a dose-response study. Critical Care Medicine 31(6): 1771-1779, 2003

Addition of Hemoglobin-Based Oxygen Carrier Hemoglobin Glutamer-200 to 6 % Hetastarch Solution Improves Restoration of Hemodynamic Parameters but Not Oxygen Delivery in a Canine Hypovolemia Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2001): Abstract No. A-391, 2002

Absence of developmental toxicity in a canine model after infusion of a hemoglobin-based oxygen carrier: Implications for risk assessment. Reproductive Toxicology 52: 101-107, 2015

Measuring Circulating Blood Volume Using Infused Hemoglobin-Based Oxygen Carrier as an Indicator Validation in a Canine Hypovolemia Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting: Abstract No. A-729, 2003

Oxygen saturation measurements in canine blood containing hemoglobin glutamer-200 (Bovine): in vitro validation of the NOVA CO-Oximeter. Veterinary Clinical Pathology 30(1): 39-45, 2001