Validity of arterial and mixed venous oxygen saturation measurements in a canine hemorrhage model after resuscitation with varying concentrations of hemoglobin-based oxygen carrier



Validity of arterial and mixed venous oxygen saturation measurements in a canine hemorrhage model after resuscitation with varying concentrations of hemoglobin-based oxygen carrier



Anesthesia and Analgesia 96(1): 46



In this study, we evaluated the validity of saturation measurements in mixed venous and arterial blood during posthemorrhagic anemia and resuscitation with varying levels of hemoglobin-based oxygen carrier (Hemoglobin glutamer-200 [bovine]; Oxyglobin [Hb-200]). Nineteen anesthetized, splenectomized, mixed-breed dogs were anesthetized (two were excluded from the data because they did not survive the exsanguination, supporting the validity of the model). Their pulmonary arteries were cannulated with the Abbott QVUE Oximetrix 3 catheter. An 18-gauge catheter was placed in the femoral artery, and a reusable Nellcor probe was applied to the tongue. Mixed venous and arterial samples were drawn at baseline, after 40% hemorrhage (to keep arterial pressure at 50 mm Hg), and postresuscitation with 30 mL/kg of 6% hetastarch in lactated Ringer's solution (n = 4), 10 mL/kg of Hb-200, 20 mL/kg of hetastarch (n = 6), 20 mL/kg of Hb-200, and 10 mL/kg of hetastarch (n = 7). Samples were compared with oxygen content from the LEXO2CON-K oxygen analyzer, and oxygen content was calculated for all values from the monitors. Results were compared by using analysis of variance. There was good correlation (0.97 > or = r > or = 0.92) for the measured versus calculated hemoglobin oxygen saturation values at baseline. After resuscitation, the correlation between calculated and measured values of oxygen content was significantly smaller for all tested instruments. The values of oxygen content calculated from the oxygen saturation monitor and from the oximetric pulmonary artery can deviate by as much as 20% from directly measured values. We conclude that the administration of this oxygen therapeutic may interfere with the values of some monitors. This study evaluated oxygen saturation monitors in a canine model of acute blood loss and resuscitation with a blood substitute and found that these may interfere with the monitors' results in a dose-dependent way.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 047915736

Download citation: RISBibTeXText

PMID: 12505921


Related references

Validity of arterial and mixed venous oxygen saturation measurements in a canine hemorrhage model after resuscitation with varying concentrations of hemoglobin-based oxygen carrier. Anesthesia and Analgesia 96(1): 46-50, 2003

Mixed Venous Oxygen Saturation Measured with an Abbot Oximetric Pulmonary Artery Catheter, and Instrumentation Laboratory Co-Oximeter after Resuscitation with Varying Concentrations of Hemoglobin-Based Oxygen Carrier in a Dog Hemorrhage Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2001): Abstract No A-556, 2002

Comparing Arterial Oxygen Saturation from a Nellcor Oxygen Saturation Monitor, IL Co-Oximeter and with Varying Concentrations of Hemoglobin-Based Oxygen Carrier in a Dog Hemorrhage Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2001): Abstract No A-557, 2002

Validation of oxygen saturation measurements in a canine model of hemoglobin-based oxygen carrier infusion. American Journal of Therapeutics 10(1): 21-28, 2003

Validation of oxygen saturation measurements in a canine model of hemoglobin based oxygen carrier (HBOC) infusion. Clinical Laboratory Science 13(2): 173-179, 2000

Augmented Oxygen Offloading by the Hemoglobin-Based Oxygen Carrier Hemoglobin Glutamer-200 Following Resuscitation in a Canine Hypovolemia Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting: Abstract No A-679, 2002

Validation of in vivo MR measurement of oxygen saturation after resuscitation with a hemoglobin-based oxygen carrier in a rabbit model. Academic Radiology 8(7): 583-590, 2001

Resuscitation with a novel hemoglobin-based oxygen carrier in a Swine model of uncontrolled perioperative hemorrhage. Journal of Trauma 54(5): 915-924, 2003

Validity and limitations of mixed venous oxygen saturation in resuscitation. Minerva Anestesiologica 57(12 Suppl): 127-132, 1991

Effects of a novel hemoglobin-based oxygen carrier on percent oxygen saturation as determined with arterial blood gas analysis and pulse oximetry. Annals Of Emergency Medicine. 27(2): 164-169, 1996

Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions. Anesthesiology 103(2): 249-257, 2005

Resuscitation following severe, controlled hemorrhage associated with a 24 h delay to surgical intervention in swine using a hemoglobin based oxygen carrier as an oxygen bridge to definitive care. Resuscitation 74(2): 332-343, 2007

Implications of altered hemoglobin concentration with variations in oxygen consumption, arterial oxygen saturation, and age based on a mathematical model for the utilization of reserve oxygen transport capacity. Advances in Experimental Medicine and Biology 180: 523-529, 1984

Resuscitation with the hemoglobin-based oxygen carrier, HBOC-201, in a swine model of severe uncontrolled hemorrhage and traumatic brain injury. Shock 31(1): 64-79, 2009

Validation of MR In-Vivo Measurement of Oxygen Saturation after Resusciation with a Hemoglobin-Based Oxygen Carrier in a Rabbit Model. Anesthesiology Abstracts of Scientific Papers Annual Meeting (2000): Abstract No 417, 2002