+ Site Statistics
References:
54,258,434
Abstracts:
29,560,870
PMIDs:
28,072,757
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

A description of a prototype miniature extracorporeal membrane oxygenation circuit using current technologies in a sheep model



A description of a prototype miniature extracorporeal membrane oxygenation circuit using current technologies in a sheep model



Journal of Extra-Corporeal Technology 37(3): 315-317



In the United States, standardization of neonatal extracorporeal membrane oxygenation (ECMO) circuit was achieved during the 1980s. Since that time, the consoles and components of the ECMO circuit have remained fundamentally unchanged (bladder, rollerpump, silicone membrane oxygenator). Extracorporeal technology, however, has witnessed many significant advancements in components during the past two decades. These new technologies have characteristics that may improve outcomes when applied in the ECMO arena. Understanding how these technologies perform in long-term applications is necessary. Therefore, the purpose of this project is to evaluate the performance of a miniature ECMO circuit consisting of current generation technologies in an animal model. An ECMO circuit (prime volume 145 mL) was designed that included a hollow fiber oxygenator and a remote mounted centrifugal pump. All circuit tubing and components were surface coated. Three sheep (approx 13 kg) were placed on ECMO using standard neck cannulation techniques and maintained according to clinical protocols. Technical implementation, oxygenator function, and hematological parameters were accessed. Duration of ECMO was 20, 48, and 58 hours. There was no evidence of oxygenator failure, as measured by pressure drop and oxygen transfer, in any of the procedures. No plasma leak was observed in any oxygenators. Platelet count trended downward after 24 hours. Visual inspection after ECMO showed very little evidence of gross thrombosis. This ECMO circuit design departs dramatically from the typical North American systems. The use of this console and components facilitated a 70% reduction in priming volume over a traditional ECMO circuit. Further investigations should be conducted to determine if circuit miniaturization can reduce the morbidity associated with blood product consumption and the bloods contact with the artificial surfaces of the ECMO circuitry.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 048064863

Download citation: RISBibTeXText

PMID: 16350388


Related references

Hanford miniature swine model for extracorporeal membrane oxygenation. Journal of Investigative Surgery 6(6): 503-508, 1993

Current state of neonatal extracorporeal membrane oxygenation in Colombia: description of the first cases. Archivos de Cardiologia de Mexico 84(2): 121-127, 2015

Long-term efficacy of an extracorporeal membrane oxygenation simulation with a novel, low-cost vascular model "Endo-Circuit". Acute Medicine and Surgery 4(1): 79-88, 2017

Soluble fibrin is a useful marker for predicting extracorporeal membrane oxygenation circuit exchange because of circuit clots. Journal of Artificial Organs 21(2): 196-200, 2018

Where should the hemofiltration circuit be placed in relation to the extracorporeal membrane oxygenation circuit?. Asaio Journal 38(4): 801-803, 1992

Selective heparinization of the extracorporeal membrane oxygenation circuit using continuous infusions of protamine and heparin in a short-term pig model. Perfusion 9(5): 327-333, 1994

Flow Rate Through Pigtail Catheter Used for Left Heart Decompression in an Artificial Model of Extracorporeal Membrane Oxygenation Circuit. Asaio Journal 63(3): 346-350, 2017

Incorporation of a hemofilter circuit into venoarterial extracorporeal membrane oxygenation: a novel approach to provide more oxygenation. Intensive Care Medicine 41(4): 729-730, 2015

Extracorporeal Membrane Oxygenation to Support Cardiopulmonary Resuscitation in a Sheep Model of Refractory Ischaemic Cardiac Arrest. Heart Lung & Circulation 22(6): 421-427, 2013

Clinical management of the extracorporeal membrane oxygenation circuit. Pediatric Critical Care Medicine 14(5 Suppl 1): S13-S19, 2014

Is the venoarterial extracorporeal membrane oxygenation circuit your frenemy?. Journal of Thoracic and Cardiovascular Surgery 155(2): 641-642, 2017

Antifungal Extraction by the Extracorporeal Membrane Oxygenation Circuit. Journal of Extra-Corporeal Technology 49(3): 150-159, 2018

Lipid emulsion layering in extracorporeal membrane oxygenation circuit. Intensive Care Medicine 42(11): 1806-1807, 2016

One-way valve malfunction in an extracorporeal membrane oxygenation priming circuit. Journal of Extra-Corporeal Technology 46(1): 98-100, 2014

Tattered and torn: the life of a RBC on the extracorporeal membrane oxygenation circuit. Critical Care Medicine 42(5): 1314-1315, 2014