Accuracy of automated instruments used in the pharmaceutical industry for integrity testing sterilizing filters



Accuracy of automated instruments used in the pharmaceutical industry for integrity testing sterilizing filters



Pda Journal of Pharmaceutical Science and Technology 57(4): 277-286



In the pharmaceutical industry, the integrity of sterile filters is critical to ensure sterility of filtered products. Filter integrity is frequently tested by measuring gas diffusion across water-contacting hydrophobic or hydrophilic membranes with the same automated test devices. Constant device accuracy over the whole range of possible operating conditions is an especially important requirement, as set by the GMP regulations for product critical devices. In this paper, we investigate the accuracy of gas diffusion rate and water intrusion rate estimates provided by a batch-operated and a refilling, continuous-flow commercial automated test device used both for diffusive flow tests and water intrusion tests. Tests were performed on custom-designed model filter systems and full-scale filters over a broad range of gas diffusive flow rates and upstream gas volumes. Neither tested device provided accurate measurements of gas diffusion rate when a small gas diffusion flow was measured out of a very large upstream volume. The batch-operated device provided measurements of gas diffusion rates (either gas diffusion or water intrusion rate) with an accuracy that strongly depends on the gas diffusion rate and on the gas volume upstream from the membrane. Gas diffusion rate measurements were particularly biased in diffusive flow tests of filters with less than 500 mL gas upstream volume. Gas diffusion rates were underestimated by as much as -14.5% in diffusive flow tests and -25% in water intrusion tests. The refilling, continuous flow device generally provided consistent and accurate gas diffusion rate and water intrusion rate measurements within less than 5% of the reference value, practically independent of the gas diffusion flow rate and upstream volume value. A serious bias was only noted in diffusion flow tests at very high upstream volumes and low gas diffusion rate. The results reported in this paper show the importance of qualifying the automated test devices used to assess sterile filter integrity.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 048153423

Download citation: RISBibTeXText

PMID: 14558701


Related references

Product-wet integrity testing of sterilizing grade filters--points to consider. Pda Journal of Pharmaceutical Science and Technology 62(5): 313-317, 2008

Pre-use/Post-sterilization Integrity Testing of Sterilizing Grade Filters. Pda Journal of Pharmaceutical Science and Technology 66(5): 394-395, 2016

Current choices of sterilizing grade membrane filters available to the pharmaceutical industry. Pda Journal of Pharmaceutical Science and Technology 55(4): 207-208, 2001

Evaluation of recovery filters for use in bacterial retention testing of sterilizing-grade filters. Pda Journal of Pharmaceutical Science and Technology 50(3): 147-153, 1996

Container Closure Integrity Testing-Practical Aspects and Approaches in the Pharmaceutical Industry. Pda Journal of Pharmaceutical Science and Technology 71(2): 147-162, 2016

Air-Water Binary Gas Integrity Test for Sterilizing and Virus Filters. Pda Journal of Pharmaceutical Science and Technology 70(6): 577-590, 2016

An assessment of test criteria for evaluating the performance and integrity of sterilizing filters. Bulletin of the Parenteral Drug Association 31(4): 187-194, 1977

A method for checking the integrity and quality of membrane filters for sterilizing nutrient culture media. Meditsinskaia Parazitologiia i Parazitarnye Bolezni 1989(6): 67-68, 1989

Methods for controlling the integrity of membrane filters for the sterilizing filtration of liquids in the production of injectable solutions a review. Khimiko-Farmatsevticheskii Zhurnal 24(2): 166-170, 1990

Comparison of four electrolyte instruments using the proposed NCCLS protocol for evaluation of precision and accuracy of automated instruments. Clinical Biochemistry 13(4): 164-170, 1980

Practical considerations for the nondestructive testing of sterilizing grade filters. Pharmaceutical Technology 13(8): 37, 1989

Pharmaceutical container/closure integrity. V: An evaluation of the WILCO "LFC" method for leak testing pharmaceutical glass-stoppered vials. Pda Journal of Pharmaceutical Science and Technology 53(5): 235-239, 2001

Preparation and purification of phix 174 cs 70 am 3 and t 1 bacteriophage atcc 11303 b for use in aerosol challenge testing of sterilizing grade membrane filters. Abstracts of the Annual Meeting of the American Society for Microbiology 89: 339, 1989

Development of serum-free media for the cultivation and recovery of Acholeplasma laidlawii used for challenge testing sterilizing-grade filters in biopharmaceutical applications. Pda Journal of Pharmaceutical Science and Technology 62(6): 402-420, 2009

The calibration of automated instruments for accuracy in hemoglobinometry. American Journal of Clinical Pathology 68(1 Suppl): 180-184, 1977