+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Assessment of an aortosaphenous vein graft anastomotic device in coronary surgery: clinical experience and early angiographic results



Assessment of an aortosaphenous vein graft anastomotic device in coronary surgery: clinical experience and early angiographic results



Annals of Thoracic Surgery 74(6): 2101-2105



Until now technologic evolution in coronary bypass surgery has focused on extracorporeal circulation, on operation without extracorporeal circulation, and on the exposure of the operative site. Recently a one-shot anastomotic device for the proximal anastomosis in coronary surgery was developed. We investigated whether the use of the aortic connector system (ACS) could facilitate the creation of aortosaphenous vein graft anastomoses in myocardial revascularization. From November 2000, 40 ACS devices were used in 36 consecutive patients (mean age 70.7 +/- 8.9 years); 12 patients (33.3%) underwent surgery on pump and 24 patients (66.6%) off pump; 50 distal anastomoses were performed. In all cases the connection with the ascending aorta was created before the distal anastomoses because of the necessity to slide the saphenous vein graft (SVG) over the vein transfer sheath. Intraoperative graft function was tested measuring blood flow by Doppler analysis. Postoperative evaluation of the anastomotic patency was carried out by early angiography in 34 patients (94.7%) but was excluded in 5 patients (5.3%) with extensive extracardiac vascular occlusive disease. Of 38 AC (95%) evaluated, 36 (94.7%) functioned properly. The end-to-side proximal anastomosis without aortic clamping is instantaneous, the quality of anastomoses was highly rated, no additional stitches were required, and all coronary arteries could be reached. Intraoperative quantity flow was measured by Doppler analysis and all but one showed good flow. Early postoperative angiography demonstrated good patency of the grafts in all cases but 2 (5.3%). At 1-year follow-up, 1 patient died of stroke; all other patients remained free of symptoms and no reoperation was required. The use of ACS makes end-to-side anastomosis rapid, effective, and reproducible while eliminating aortic cross clamping; it opens a new era in beating or nonbeating coronary surgery. Long-term results are mandatory to confirm our favorable preliminary results.

Please choose payment method:






(PDF emailed within 1 workday: $29.90)

Accession: 048319487

Download citation: RISBibTeXText

PMID: 12643402


Related references

Early results of new style aortosaphenous vein graft connector in coronary artery bypass grafting. Kyobu Geka. Japanese Journal of Thoracic Surgery 59(12): 1051-5; Discussion 1055-9, 2006

Long-term clinical and angiographic outcomes in patients with diabetes undergoing coronary artery bypass graft surgery: results from the Project of Ex-vivo Vein Graft Engineering via Transfection IV trial. American Heart Journal 169(1): 175-184, 2015

Saphenous vein bypass graft surgery for coronary artery disease long term clinical and angiographic results. Circulation Suppl. 50(4-3): III132, 1974

Intraoperative and intermediate-term angiographic results of coronary artery bypass surgery with Symmetry proximal anastomotic device. Journal of Thoracic and Cardiovascular Surgery 128(5): 718-723, 2004

Six-month angiographic evaluation of beating-heart coronary arterial graft interrupted anastomoses using the coalescent U-CLIP anastomotic device: a prospective clinical study. Heart Surgery Forum 5(4): 319, 2002

Vein graft surgery for coronary artery disease. Survival and angiographic results in 1,000 patients. Circulation 48(1 Suppl): Iii184, 1973

Clinical experience with the Ventrica distal anastomotic device in coronary surgery. Minimally Invasive Therapy and Allied Technologies 13(1): 26-31, 2004

Early clinical experience with a new sutureless anastomotic device for proximal anastomosis of the saphenous vein to the aorta. Journal of Thoracic and Cardiovascular Surgery 121(5): 854-858, 2001

Sequential saphenous vein conduits for coronary artery bypass graft surgery: long-term survival and angiographic results. Annals of Thoracic Surgery 89(5): 1704-5; Author Reply 1705, 2010

Impact of glucose control on early vein graft failure after coronary artery bypass grafting: one-month angiographic results. Interactive Cardiovascular and Thoracic Surgery 24(2): 216-221, 2017

Clinical experience with the Novare Enclose II manual proximal anastomotic device during off-pump coronary artery surgery. European Journal of Cardio-Thoracic Surgery 27(6): 1070-1073, 2005

Coronary acute syndrome due to a large occlusive thrombus in an aortosaphenous vein graft. Journal of Invasive Cardiology 23(2): 87, 2011

Aorto-coronary bypass with graft of the saphenous vein (108 cases). Clinical, angiographic and functional long-term results. Giornale Italiano di Cardiologia 2(5): 644-654, 1972

The pCONus2 Neck-Bridging Device: Early Clinical Experience and Immediate Angiographic Results. World Neurosurgery 110: E766-E775, 2018

Aorta-coronary artery saphenous vein bypass surgery: clinical and angiographic results. Mayo Clinic Proceedings 50(7): 379-386, 1975