+ Site Statistics
+ Search Articles
+ PDF Full Text Service
How our service works
Request PDF Full Text
+ Follow Us
Follow on Facebook
Follow on Twitter
Follow on LinkedIn
+ Subscribe to Site Feeds
Most Shared
PDF Full Text
+ Translate
+ Recently Requested

Brain SPECT with short focal-length cone-beam collimation



Brain SPECT with short focal-length cone-beam collimation



Medical Physics 32(7): 2236-2244



Single-photon emission-computed tomography (SPECT) imaging of deep brain structures is compromised by loss of photons due to attenuation. We have previously shown that a centrally peaked collimator sensitivity function can compensate for this phenomenon, increasing sensitivity over most of the brain. For dual-head instruments, parallel-hole collimators cannot provide variable sensitivity without simultaneously degrading spatial resolution near the center of the brain; this suggests the use of converging collimators. We have designed collimator pairs for dual-head SPECT systems to increase sensitivity, particularly in the center of the brain, and compared the new collimation approach to existing approaches on the basis of performance in estimating activity concentration of small structures at various locations in the brain. The collimator pairs we evaluated included a cone-beam collimator, for increased sensitivity, and a fan-beam collimator, for data sufficiency. We calculated projections of an ellipsoidal uniform background, with 0.9-cm-radius spherical lesions at several locations in the background. From these, we determined ideal signal-to-noise ratios (SNRCRB) for estimation of activity concentration within the spheres, based on the Cramer-Rao lower bound on variance. We also reconstructed, by an ordered-subset expectation-maximization (OS-EM) procedure, images of this phantom, as well as of the Zubal brain phantom, to allow visual assessment and to ensure that they were free of artifacts. The best of the collimator pairs evaluated comprised a cone-beam collimator with 20 cm focal length, for which the focal point is inside the brain, and a fan-beam collimator with 40 cm focal length. This pair yielded increased SNRCRB, compared to the parallel-parallel pair, throughout the imaging volume. The factor by which SNRCRB increased ranged from 1.1 at the most axially extreme location to 3.5 at the center. The gains in SNRCRB were relatively robust to mismatches between the center of the brain and the center of the imaging volume. Artifact-free reconstructions of simulated data acquired using this pair were obtained. Combining fan-beam and short-focusing cone-beam collimation should greatly improve dual-head brain SPECT imaging, especially for centrally located structures.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048405278

Download citation: RISBibTeXText

PMID: 16121578

DOI: 10.1118/1.1929208


Related references

Speedup OS-EM Image Reconstruction by PC Graphics Card Technologies for Quantitative SPECT with Varying Focal-Length Fan-Beam Collimation. IEEE Transactions on Nuclear Science 52(5 Pt 1): 1274-1280, 2005

Brain SPECT Simulation Using Half-Cone-Beam Collimation and Single-Revolution Helical-Path Acquisition. IEEE Transactions on Nuclear Science 54(3): 475-479, 2007

An evaluation of lesion detectability with cone beam, fan beam and parallel beam collimation in SPECT by continuous ROC analysis. Journal of Nuclear Medicine 34(5 Suppl. ): 81P, 1993

Cardiac SPECT using combined cone-beam and fan-beam collimation. Journal of Nuclear Medicine 44(5 Suppl.): 63P, 2003

An evaluation of lesion detectability with cone-beam, fanbeam and parallel-beam collimation in SPECT by continuous ROC study. Journal of Nuclear Medicine 35(1): 135-140, 1994

Half-cone beam collimation for triple-camera SPECT systems. Journal of Nuclear Medicine 37(3): 498-502, 1996

Variance distribution in reconstructed images in 3 d spect using cone beam collimation. Journal Of Nuclear MedicineSuppl.: 678, 1987

Use of cone beam collimation for magnification SPECT bone imaging of the extremities. Journal of Nuclear Medicine 34(5 Suppl. ): 142P-143P, 1993

Evaluation of combined cone beam with parallel hole collimation spect data. Journal of Nuclear Medicine 32(5 Suppl.): 956, 1991

Breast cancer detection using vertical axis-of-rotation SPECT with half-cone beam collimation. Journal of Nuclear Medicine 38(5 Suppl. ): 220P, 1997

A comparison of parallel beam, fan beam, and cone beam collimators for 3D SPECT brain imaging based on mutual information criterion. Journal of Nuclear Medicine 34(5 Suppl. ): 195P-196P, 1993

High resolution iodine 123 hipdm brain spect with fan beam collimation. Journal Of Nuclear MedicineSuppl.: 570, 1987

An inversion formula for the exponential radon transform in spatial domain with variable focal-length fan-beam collimation geometry. Medical Physics 33(3): 792-798, 2006

Fan beam collimation with off center focus for simultaneous emission/transmission SPECT in multi-camera SPECT systems. Journal of Nuclear Medicine 35(5 Suppl. ): 92P, 1994

Cone beam spect of the brain using two orbits. Journal of Nuclear Medicine 31(5 Suppl.): 770, 1990