Chest radiography: a comparison of image quality and effective dose using four digital systems



Chest radiography: a comparison of image quality and effective dose using four digital systems



Radiation Protection Dosimetry 114(1-3): 273-277



Image quality (IQ) and effective dose for chest radiography was compared for four digital imaging systems that used three different detector technologies: a-Si/TFT flat-panel detector (FPD), scanning-slot/charge-coupled device (CCD) and photostimuable phosphor (PSP). On each system a phantom was exposed at 125 kV(p) for automatic exposure control (AEC) and 2, 4 and 8 Gy receptor dose using identical geometrical conditions. All images were scored as softcopy images by three observers. The effective dose was calculated for each exposure condition. For AEC, superior IQ was observed for the GE FPD compared with all the other systems, which showed similar IQ performance. For all systems the entrance surface dose associated with AEC was within the European recommendations but variations in the effective dose were observed between the four systems. For identical receptor dose levels superior IQ was observed with the FPDs. Thorascan was noted for its low effective dose and Agfa CR was associated with the highest effective dose. FPD systems showed a better overall performance, followed by the CCD and PSP systems.

Please choose payment method:






(PDF emailed within 0-6 h: $19.90)

Accession: 048505684

Download citation: RISBibTeXText

PMID: 15933121

DOI: 10.1093/rpd/nch572


Related references

Optimization of chest radiographic imaging parameters: a comparison of image quality and entrance skin dose for digital chest radiography systems. Clinical Imaging 36(4): 279-286, 2012

Image quality of supine chest radiographs: intra-individual comparison of computed radiography and low-dose linear-slit digital radiography. European Radiology 19(9): 2156-2162, 2009

Comparison of Wireless Detectors for Digital Radiography Systems: Image Quality and Dose. Radiation Protection Dosimetry 169(1-4): 303-307, 2016

Dose-image quality optimisation in digital chest radiography. Radiation Protection Dosimetry 114(1-3): 269-272, 2005

Dose reduction in digital chest radiography and perceived image quality. British Journal of Radiology 80(960): 984-988, 2007

Digital chest radiography image quality assessment with dose reduction. Australasian Physical and Engineering Sciences in Medicine 35(1): 71-80, 2012

Dose-image quality study in digital chest radiography using Monte Carlo simulation. Applied Radiation and Isotopes 66(9): 1213-1217, 2008

A technique for simulating the effect of dose reduction on image quality in digital chest radiography. Journal of Digital Imaging 22(2): 114-125, 2009

Digital chest radiography: an update on modern technology, dose containment and control of image quality. European Radiology 18(9): 1818-1830, 2008

Slot-scan digital radiography of the lower extremities: a comparison to computed radiography with respect to image quality and radiation dose. Korean Journal of Radiology 10(1): 51-57, 2009

Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging. Medical Physics 38(1): 23-33, 2011

Towards image quality, beam energy and effective dose optimisation in digital thoracic radiography. European Radiology 11(5): 870-875, 2001

Evaluating radiographic parameters for mobile chest computed radiography: phantoms, image quality and effective dose. Medical Physics 30(10): 2727-2735, 2003

Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: image quality and potential for dose reduction in comparison with screen-film radiography. Clinical Radiology 55(8): 615-621, 2000

Image quality and radiation dose on digital chest imaging: comparison of amorphous silicon and amorphous selenium flat-panel systems. Ajr. American Journal of Roentgenology 187(3): 630-637, 2006